| 1 | Generator |
| 2 | OD377453/2025-2026:Supply, Loading, Conveyance, unloading, and erection of 100 KVA DG Set with Acoustic enclosure as per CPCB IV+ norms and as detailed below. 1. Enginea. Make of engine - Kirloskar, Mahindra, Ashok lyleand, Cuminsb. Type of Engine - Diesel Engine.c. No of Cylinders - As per manufactures standard.d. Method of cooling - Water cooled with radiator.e. Aspiration - Naturally Aspirated.f. Design - Suitable for generating set operation.g. Output - Suitable for generating set operation.2. Standard accessories with Diesel Enginea. Fly wheel.b. Close Coupled.c. Air cleaner.d. Radiator with fan provided with fan guard.e. Fuel Pump.f. Mechanical /Electronic governor.g. Fuel filter.h. Lubricating oil filter.i. Residential type exhaust silencer. j. Battery Charger / Generator.3. Engine Instrument Panel with the following items.a. Starting switch with key or button and Remote controlb. Lubricating oil pressure gauge.c. Water temperature gauge.d. RPM Indicator with hour meter. e. Battery charging ammeter.4. Safety Controls for Enginea. Battery control (trip) for low lubricating oil pressure.a. Battery control (trip) for high water temperature.5. Brush less alternatora. Make - Kirloskar/ KEL/Stamford/Crompton/Integrated electric Ltdb. Type - Self exited and self regulatedc. Capacity - 100 KVA / 80 KW @ 0.8PFd. System of Voltage - 3Phase, 415V, 4 Wire system.f. Speed - 1500 rpm.g. Frequency - 50Hz.h. Insulation - Class F/HThe alternator should confirm to IS 4722/IS13365. Operation and service manual shall be provided6. Fuel TankSuitable size fitted (built in type) inside the acoustic enclosure 7. BatterySuitable size fully charged battery with leads and terminals of appropriate AH capacity as per Manufactures required including battery charger.8. Standard control panela.160 A 4 Pole MCCB Set at 130 Ab. 1No multi function meter suitable for display of current in 3Phases, voltage in 3Phases, frequency, power factor, KVA, KVAh, KVAr, KVArh, KW etc.c. 1 No separate KWH meter d. Necessary measuring CTs of appropriate ratio and burden for the required meter.d. Instrument fuse/MCB - 2setf. Metallic DNB - 1Nog. Solid state phase indication lamp for supply ON/OF with Fuse / MCB protection. |
| 3 | OD382698/2025-2026:Supply and installation, testing and commissioning of ATS Panel suitable for 100KVA Diesel Generator set in the existing Cubicle including required all accessories as required. |
| 4 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 5 | 90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 6 | 90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 7 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 8 | OD377302/2025-2026:Supply of High speed Speed Diesel for test run |
| 9 | OD377311/2025-2026:Charges for conducting load test |
| 10 | OD377299/2025-2026:Supply and providing 2 mm thick & 1 m wide electrical grade chequered type insulation mat to withstand 3.3 KV dielectric strength conforming to IS 15652/06 |
| 11 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 12 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 13 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 14 | 90.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm |
| 15 | 90.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size |
| 16 | 90.12.5.32:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 120 sq mm |
| 17 | 90.6.4.10:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 10 Run |
| 18 | 9.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 19 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 20 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 21 | 90.16.3.2:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm GI strip |
| 22 | OD377309/2025-2026:Supply and providing test joint for the earthing system using 2 x 25 x 3 mm GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required |
| 23 | OD377310/2025-2026:Supply and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required |
| 24 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 25 | 90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 26 | 90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip |
| 27 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 28 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 29 | OD377297/2025-2026:Supply and providing the 25 x 3mm brass bolt & nut with washers on the existing MS box/ earth bus etc. as required including drilling necessary holes as required |
| 30 | OD377301/2025-2026:Supply and installation of ABC type fire extinguisher of 6 kg. Capacity complete with initial charges and installation brackets, with ISI mark IS:15222. |
| 31 | OD382953/2025-2026:Supply conveyance and providing 80 mm MS pipe or nearest size dia.with required accessories for exhaust pipe to generator. |
| 32 | OD383770/2025-2026:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required-2.50 cm, 4 cm or 5 cm height |
| 33 | OD383769/2025-2026:Statutory Fee and other deposit amount to KSELB & KSEB for approval from the concerned department for generator installation. (LS provision as per the receipt) |
| 34 | OD383771/2025-2026:Charges for preparation and submission of documents such as plan,scheme etc for approval of Generator installation from KSELB& KSEB (Excluding CD Charge) |
| 35 | Generator Shed |
| 36 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 37 | 4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 38 | 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 39 | 12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm) |
| 40 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 41 | 13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 42 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Please Enable Macros to View BoQ information |