| 1 | CIVIL WORK |
| 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m inwidth as well as 10 sqm on plan including disposal of excavated earth up to 50 m andlift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 5 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 6 | Providing and laying in position cement concrete of specified grade excluding the costof centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarsesand (zone-III) derived from natural sources : 10 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Providing and laying cement concrete in retaining walls, return walls, walls ( anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks,plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the costof centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derivedfrom natural sources) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 9 | Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Centering and shuttering including strutting, etc. and removal of form for:Foundations,footings, bases of columns, etc for mass concrete |
| 11 | Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 12 | Centering and shuttering including strutting, etc. and removal of form for:Small lintelsnot exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses,bands, copings, bed plates, anchor blocks and the like |
| 13 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 14 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - Mechanically Treatedbars of grade Fe-500D or more |
| 15 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. |
| 16 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:150x10 mm |
| 17 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows andclerestory windows using wire gauge with average width of aperture 1.4 mm in bothdirections with wire of dia 0.50 mm all complete.With 12 mm mild steel U beading |
| 18 | Structural steel work riveted, bolted or welded in built up sections, trusses and framedwork, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. |
| 19 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes |
| 20 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to bespecified by the manufacturer), of Ist quality conforming to IS : 15622, of approvedmake, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing thejoints with white cement and matching pigments etc., complete. |
| 21 | Providing and laying Vitrified tiles in floor in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS:15622, of approved brand & manufacturer, in all colours andshade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting the joints with whitecement and matching pigments etc. The tiles must be cut with the zero chippingdiamond cutter only . Laying of tiles will be done with the notch trowel, plier,wedge, clips of required thickness, leveling system and rubber mallet for placingthe tiles gently and easily.Double charge vitrified tile polished finish of sizeSize of Tile 600 x 600 mm |
| 22 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by themanufacturer), with water absorption less than 0.08% and conforming to IS : 15622, ofapproved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laidwith cement based high polymer modified quick set tile adhesive (water based)conforming to IS : 15477, in average 6 mm thickness, including grouting of joints(Payment for grouting of joints to be made separately).Size of Tile 600x600 mm |
| 23 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm |
| 24 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mmdiameter |
| 25 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required. |
| 26 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm(+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyestertop coat 15-18 microns using self drilling/ self tapping screwscomplete :Flashings /Aprons (Upto 600 mm) |
| 27 | 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 28 | 15 mm cement plaster on the rough side of single or half brick wall of mix:1:6 ( 1cement : 6 fine sand) |
| 29 | 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 30 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives ofrequired shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over andincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture of requiredcolour to give an even shade:Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture . |
| 32 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC(Volatile including applying additional coats wherever required to achieve even shadeand colour.One coat |
| 33 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC(Volatile including applying additional coats wherever required to achieve even shadeand colour.Two coats |
| 34 | Removing dry or oil bound distemper, water proofing cement paint and the like byscrapping, sand papering and preparing the surface smooth including necessary repairsto scratches etc. complete. |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of requiredcolour to give an even shade :One or more coats on old work |
| 36 | Finishing walls with Premium Acrylic Smooth exterior paint with Siliconeadditives of required shadeOld work (Two or more coats applied @ 1.43 ltr/ 10 sqm)over existing cementpaint surface |
| 37 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed withearth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 38 | Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In cement mortar |
| 39 | Taking out doors, windows and clerestory window shutters (steel or wood ) includingstacking within 50 metres lead:Of area beyond 3 sq. metres |
| 40 | Disposal of building rubbish/ malba/ similar unserviceable, dismantled or wastematerials by mechanical means, including loading, transporting, unloading toapproved municipal dumping ground or as approved by Engineer-in-charge, beyond50 m initial lead, for all leads including all lifts involved |
| 41 | Supplying at site Angle iron post & strut of required size including bottom to be splitand bent at right angle in opposite direction for 10 cm length and drilling holes upto 10mm dia. etc. complete. |
| 42 | Providing and fixing concertina coil fencing with punched tape concertina coil 600mm dia 10 metre openable length (total length 90 m) , having 50 nos rounds per 6metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 mor 3.00 apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I.staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wiretied to angel iron, all complete as per direction of Engineer- in-charge, with reinforcedbarbed tape (R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S.angle, C.C. blocks shall be paid separately) |
| 43 | Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C.paver block of M-30 grade with approved color design and pattern. |
| 44 | Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 45 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 46 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device(handle lever) conforming to IS: 7231, with all fittings and fixtures complete.10 litrecapacity - White |
| 47 | Providing and fixing solid plastic Seat with lid for pedestal type W.C. pancomplete:White solid plastic seat with lid |
| 48 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 withC.I. brackets and stainless steel plug 40 mm, including painting of fittings andbrackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x460 mm bowl depth 200 mm |
| 49 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 50 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter |
| 51 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. |
| 52 | Providing and fixing C.P brass long nose bib cock of approved quality conforming toIS standards and weighing not less than 810 gms.15 mm nominal bore |
| 53 | Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 54 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey combshaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as perstandard design.With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 55 | Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50micron) |
| 56 | Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mmthickness (weight not less than 12.50 kg/sqm) |
| 57 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structuralnon sag elastomeric PU sealant over backer rod of approved quality as perarchitectural drawings and direction of Engineer-in-charge complete,complying to ASTM C920, DIN 18540-F & ISO 11600Upto 5 mm depth and 5 mmwidth |
| 58 | Providing and fixing factory made precast RCC perforated drain covers, havingconcrete of strength not less than M-25, of size 1000x450x50 mm, reinforced with 8mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, includingproviding 50 mm dia perforation @ 100 to 125 mm c/c, including providing edgebinding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction ofEngineer - in- charge. |
| 59 | Laterate masonry with neatly dressed laterate stone of size 30x20x20cm or nearest sizein cement mortar 1:6 for foundation and basement including all cost of materials,labour charges etc.Details of cost for one cum. |
| 60 | Laterite masonry with neatly dressed laterite stone of size 30x20x20 cm or nearest sizein cement mortar 1:6 for super structure above plinth level up to floor two level includingall cost of materials, labour charges etc. |
| 61 | Providing and fixing 15 cm x 15 cm square Rigid PVC gutter with iron brackets 25 x 3mm size, bolts, nuts and washers etc. including making necessary connections with rainwater pipes compl |
| 62 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge. |
| 63 | Providing and laying UPVC SWR type B pipes conforming to IS 13592 for soil wasteand vent pipes. |
| 64 | Labour |
| 65 | Construction of well |
| 66 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, including gettingout the excavated soil and disposal of surplus excavated soil as directed, within a leadof 50 m.All kinds of soil |
| 67 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavatedor stacked materials.All kinds of soil |
| 68 | Laterite masonry with neatly dressed stone of size 35x20x20 cm or nearest size incement mortar 1:6 for well lining including cost and conveyance of all materials andall labour charges etc complete (MOD 50.6.7.1 of DAR with additional labour fordressing and lifting) |
| 69 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primerall complete.Fixed to steel windows by welding |
| 70 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 71 | Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 72 | Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work |
| 73 | Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work |
| 74 | Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest sizein cement mortar 1:6 for foundation and basement including all cost of materials,labour charges etc. |
| 75 | Providing and laying in position cement concrete of specified grade excluding the costof centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarsesand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 76 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes |
| 77 | ELECTRICAL WORK |
| 78 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 79 | 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessed mediumclass PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 80 | 1.14.5Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessed mediumclass PVC conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 81 | OD174386/2025-2026 Providing, laying and fixing following dia G.I. pipe (medium class) in groundcomplete with G.I. fittings including trenching (75 cm deep)and re-filling etc asrequired 25 mm dia |
| 82 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch |
| 83 | 1.24.2Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.2 way 5/6 amps switch |
| 84 | 1.28.1Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module |
| 85 | 1.28.2Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module |
| 86 | 1.28.5 Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.8 Module |
| 87 | 1.28.6Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.12 Module |
| 88 | 19.1Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star ratedceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:sblades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copperwinding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Airdelivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD lessthan 10% remote or electronic regulator unit for speed control and all remainingaccesories including safety pin, nut and bolts , washers, temperature rise equal to 75deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 89 | OD175279/2025-2026Supply, Installation, testing and commissioning of 225mm sweep, 1400rpm, metalexhaust fan with inbuilt metal bird screen in existing opening including making goodthe hole to suit the size of the above fan in hylam sheet or concrete complete withconnections etc as required. |
| 90 | OD175400/2025-2026 SITC of outdoor type LED light fitting having color temperature not less than 5700K,system lumen output not less than 5250 and system wattage not less than 50 watts,CRI not less than 80, high transmittance diffuser, with surge protection not less than4KV (IP 66) , connections using 1.5 sq mm FRLS PVC insulated Copper conductor 3core cable including 1mtr long suitable GI bracket for fixing the LED fitting onbuilding outer wall surface etc , complete as required. |
| 91 | OD175401/2025-2026SITC of commercial batten type ( 2 feet) integrated LED light fitting having colortemperature not less than 5700K, system lumen output not less than 950 and systemwattage not less than 9W, CRI not less than 80, high transmittance diffuser, in-builtelectronic driver with surge protection not less than 2 kV etc. as required. |
| 92 | OD175402/2025-2026SITC of wall bracket type LED light fitting having color temperature not less than5700K, system lumen output not less than 900 and system wattage not less than 9W,CRI not less than 80, polycarbonate diffuser including suitable 9 W LED lamp etc. asrequired. |
| 93 | OD175403/2025-2026SITC of LED Bulb Light fitting having color temperature not less than 6500K, systemlumen output not less than 950 and system wattage not more than 10 W, CRI not lessthan 80, B22 base type, in-built electronic driver with surge protection not less than 2kV etc. as required. |
| 94 | OD175404/2025-2026 SITC of commercial batten type integrated LED light fitting having colortemperature not less than 5700K, system lumen output not less than 2000 and systemwattage not more than 20 W, CRI not less than 80, extruded polycarbonate housingwith PC diffuser, in-built electronic driver with surge protection not less than 2 kVetc. as required. |
| 95 | 2.3.4Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door |
| 96 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 97 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 98 | 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 99 | OD184075/2025-2026Call bell/ buzzer |
| 100 | OD184076/2025-2026Brass batten/ angle holder |
| 101 | OD184077/2025-20262 Module Stepped type Electronic fan regulator |
| 102 | OD184078/2025-2026Bell push |
| 103 | OD184079/2025-20266 pin 15/16 amp socket outlet |
| 104 | OD184080/2025-20263 pin 5/6 amp socket outlet |
| 105 | OD184081/2025-202615/16 amp switch |
| 106 | OD184084/2025-2026Supply of outdoor type LED light fitting having color temperature not less than5700K, system lumen output not less than 5250 and system wattage not less than 50watts, CRI not less than 80, high transmittance diffuser, with surge protection not lessthan 4KV (IP 66) , etc , complete as required |
| 107 | OD184085/2025-2026Supply of commercial batten type ( 2 feet) integrated LED light fitting having colortemperature not less than 5700K, system lumen output not less than 950 and systemwattage not less than 9W, CRI not less than 80, high transmittance diffuser, in-builtelectronic driver with surge protection not less than 2 kV etc. as required. |
| 108 | OD184086/2025-2026Supply of LED Bulb Light fitting having color temperature not less than 6500K,system lumen output not less than 950 and system wattage not more than 10 W, CRInot less than 80, B22 base type, in-built electronic driver with surge protection notless than 2 kV etc. as required. |
| 109 | OD184087/2025-2026Supply of commercial batten type integrated LED light fitting having colortemperature not less than 5700K, system lumen output not less than 2000 and systemwattage not more than 20 W, CRI not less than 80, extruded polycarbonate housingwith PC diffuser, in-built electronic driver with surge protection not less than 2 kVetc. as required. |
| 110 | OD184088/2025-2026Earthing by machine boring in hard laterite with G.I. earth pipe 4.5 meter long, 40 mmdia including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 111 | OD186030/2025-2026Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 112 | 1.31Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). |
| 113 | 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 6 pin 5/6 & 15/16 ampsmodular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 114 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 115 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet |
| 116 | 1.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired. |
| 117 | 1.34Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 118 | 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete asrequired. |
| 119 | EARTHING |
| 120 | 5.13Providing and laying earth connection from earth electrode with 4.00 mm dia copperwire in 15mm dia G.I. pipe from earth electrode including connection with copperthimble excavation and re-filling as required |
| 121 | 5.17Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthingas required. Please Enable Macros to View BoQ information |