| 1 | SITC of 600W (+/- 10 %) LED Floodlight with minimum 69,000 lumens package and 115 Lumens/W (+/- 5 %) efficacy for CRI ≥ 90, made up of Graphite grey powder coated pressure die‐cast aluminium LED housing designed to act as heat sink for efficient dissipation of heat. Floodlights should have heat resistant toughened glass provided with gasket to ensure ingress protection (IP66). LEDs should be provided with secondary lens optics to get optimum optical performance. Fixture should have Power Factor ≥0.95, THD <10%, Impact Protection IK08, Built-in Surge protection 4kV (min.), External Surge Protection 20kV (min.) for additional safety. Fixture should shave Correlated Color Temperature 5665±355K, Color Rendering Index >90, Television Lighting Consistency Index (TLCI) >90, Maintenance of lumen output (L90) > 1,00,000 hrs. Test report to be submitted; photo biological safety norms: IS16108, test certificate to be submitted; certification: LM 79 for luminaire and LM80 for led source, Driver and Fixture should be BIS certified. Driver should be DMX Compatible Driver used and specially designed to have built in surge voltage, open/short circuit protections. Beam angle should be Narrow (20° to 30°) to effectively illuminate Playing courts in televised condition. Operating Temperature Range shall be -10°C to +45°C. Dimensions including Driver compartment are restricted for suitability at existing Truss. Luminaire should be provided with a MS mounting bracket fixed on pressure die-cast aluminium housing for aiming adjustment. OEM should have an in-house NABL-accredited Laboratory for testing Photometric parameters and allow Inspection by Engineer-in-charge/Tender Inviting Authority at NABL accredited in-house lab before dispatch to certify Tender parameters. |
| 2 | SITC of 600W (+/- 10 %) Floodlight with minimum 80,000lumens package and 135Lumens/W (+/- 5 %) efficacy for CRI>70, made up of Graphite grey powder coated pressure die‐cast aluminium LED housing designed to act as heat sink for efficient dissipation of heat. Floodlights should have heat resistant toughened glass provided with gasket to ensure ingress protection (IP66). LEDs should be provided with secondary lens optics to get optimum optical performance. Fixture should have Power Factor ≥0.95, THD <10%, Impact Protection IK08, Built-in Surge protection 4kV (min.), External Surge Protection 20kV (min.) for additional safety. Fixture should shave Correlated Color Temperature 5665±355K, Color Rendering Index >70, Maintenance of lumen output (L70) > 1,00,000 hrs. Test report to be submitted; photo biological safety norms: IS16108, test certificate to be submitted; certification: LM 79 for luminaire and LM80 for led source, Driver and Fixture should be BIS certified. Driver should be specially designed to have built in surge voltage, open/short circuit protections. Beam angle should be Narrow (20° to 30°) to effectively illuminate Playing courts in non televised condition. Luminaire should be provided with a MS mounting bracket fixed on pressure die-cast aluminium housing for aiming adjustment. Operating Temperature Range shall be -10°C to +45°C. Dimensions including Driver compartment are restricted for suitability at existing Truss. OEM should have an in-house NABL-accredited Laboratory for testing Photometric parameters and allow Inspection by Engineer-in-charge/Tender Inviting Authority at NABL accredited in-house lab before dispatch to certify Tender parameters. |
| 3 | SITC of DMX Controller System with Standalone interfaces. USB Connection - USB-24 DMX, Ethernet Connection - Ethernet-512 DMX, Output Channels - 1024(2X512,2U.Split x2)channels split on 2 outputs(PC and Stand Alone)Input - Ethernet(RJ45,DHCP or static IP),USB-CNetworks - Ethernet, Internet, WIFI compatible when connected to a router, Node DMX - 4 ports Art-Net to DMX decoder and converter(DHCP, Static IP), DMX Modes - DMX In/Out, DMX Splitter(X4 ports),DMX Record, DMX Trigger, Multiple Zone - 5 Zone, play 5 scene/sequence per time in Stand Alone Art-Net Out - 2X512 on Ethernet(SD card required,2 universes per device), sACN Out - 2X512 on Ethernet(SD card required,2 universes per device)Memory capacity - Memory Step capacity(5K- 20K),8Mb Internal memory(NO SD required) Micro SD card – Micro SD Card(FAT format, max 256 GB, Class 10,Inside housing)Web Remote options - Web remote over internet, Housing I/O Connectors - Standard DIN-RAIL cabinet compatibility, PVC/USB-C, Screw terminal blocks with 2X9+2X6 pins, Number of Scenes - 2500, Number of Zones - 5Power voltage - 5-24V DC,0.3A/Output:5VDC,High Voltage Protection, Power connectors - Screw Terminals, Standalone options - Art-Net and sACN from SD card, including triggers (4X512) - NODE to decode Art-Net and sACN to DMX(4 Universe), Setting & configuration via app - Commands from the contacts(Speed, Scene, Dimmer, Zone), Default start scene, Scene priority, Cross Fade time between scenes - Automatic Scene Recovery if the power is cut off and 16-bit and fine channel managementApp - Pixelerr Application(iOS, Andriod Free, LAN, INTERNET)RS 232 - RS 232 In/Out (16 characters max for RS232 triggers, commands or orders)Ethrnet - UDP/Ethernet triggers and commands(from SDK)Clock/Calendar - Real Time Clock and calender for each scene (Hour, Day, Week, Month,Year)Contacts - 12 Smart Contacts on 3- 5V(On, On/off, Release, Restart, Scene Priority, 31 contacts max)Commands - Commands from the Contacts(speed, scene, dimmer, zone)Input - DMX input(DMX signal from other DMX devices)Remote - Infrared Remote Light Intensity ART+NET, sACN - 2X152 with Pixelerr software andOutput - 8X512 with Pixelerr Pro, DVI outputs - 128X128 or 16 384 pixels with - Pixelerr ProAudio/Video Timeline - 30 mns Audio and Video TimelineStudio DMX - 3D viewer in real time(Full mode), Pixelerr Mobile App - Software control mobile(Andriod , iOS)Mobile - Andriod 5/iOS10 and + 1GHz CPU,1 GB RAM,60 MB diskminimum configuration -> System - Windows, Mac, iOS, Linux, Compatibility - Configuration minimal PC - Windows, Mac OS, Linux(32 and 64 bits) - 2Ghz CPU(2 core),8 GB RAM - 2GB RAM graphic card(for 3D only) - 600MB disk, 1920X1080 resolution 1 USB port(Device) - 1 Ethernet Port(for Art-Net & sACN), Along with Controller, additional Splitter as per suitable output ports & suitable enclosure for DMX controller & Splitter. |
| 4 | Supply and installation of FRP Junction box of size 150x150x100 mm with terminal suitable for terminating 4C x 2.5 sq.mm. copper cable upto 2 nos. and 1 no. 3Cx1.5 sq.mm flexible. |
| 5 | Supply of 1.1 kV grade 4Cx2.5 sq.mm, Copper conductor, XLPE insulated, PVC sheathed, armoured cable as per IS 7098 (Part-1) - 1988 (to latest amendment). |
| 6 | Supply of .1.1 kV grade 3Cx1.5 sq.mm, Copper conductor, XLPE insulated, PVC sheathed, armoured cable as per IS 7098 (Part-1) - 1988 (to latest amendment) |
| 7 | Supply, assembly, erection, connecting, testing & commissioning of LT weather proof dust and vermin proof, indoor feeder pillar/ panel with double door and IP 55 protection, fabricated out of suitable sized angle iron and flats and covered with 2mm thick CRCA sheet steel including canopy, powder coated, both sides (front and rear) openable with locking arrangement, rubber gasket cable glands, etc. Bakelite phase separators and bus bar supports on the existing truss with suitable mounting etc. as required. The feeder pillars shall be complete with 3 phase and neutral bus bars of capacities as described below and ACB,s and MCCB,s with adjustable overload relays for incomers and outgoing circuits ( including ON indication for each MCCB to be provided) , complete in all respects as per specifications as requiredINCOMER 150 A TP MCCB, Ics=36 KA WITHT.M RLS FOR O/L+S/C WITH ROH - 1 NosBus bar4 strip aluminum bus bars of minimum of 250 Amps – 1 SetOUTGOING :- 32A, TP MCB, 10 KA (FOR Feeder Pillar) -4 Nos,32A, TP MCB, 10 KA (COMNS) -2 Nos, For Spare 2A, SP MCB, 10 KA ( FOR PHASE INDICATING LIGHT ) -30 Nos, 32A TP CONTACTOR AC-3 DUTY -1 Nos ASTRO TIME SWITCH -1 Nos TOGGLE SWITCH MANUAL BYPASS -1 Nos PUSH BUTTONS RED+1 NC (UP & DOWN) -2 Nos IND. LIGHT 220V, LED TYPE,22.5mm DIA., RED, YELLOE, BLUE -1 Nos |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as requireda) upto 35 sqmm |
| 9 | Termination of following sizes of cables:a) 1.1 kV grade 4Cx2.5 sq.mm, Copper conductor, XLPE insulated, PVC sheathed, armoured cable as per IS 7098 (Part-1) - 1988 (to latest amendment). |
| 10 | b) 1.1 kV grade 3Cx1.5 sq.mm, stranded copper conductor, PVC insulated cable as per IS 694 - 1990 (to latest amendment). |
| 11 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 12 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information |