| 1 | Providing UPS |
| 2 | OD181881/2024-2025:SITC of 20KVA 240 V DC ONLINE UPS (3PH INPUT:1PH OUTPUT) Rating ; 20KVA Technology : DSP based, IGBT inverter-lGBT converter Online UPS. DC Bus : 240 VDC Input Voltage : 415VAC, 3P & N Input Voltage Window : 330VAC - 470VAC Input Frequency : 45-55Hz Input PFC 100% load : > 0.9 Power walk in : Soft start for 0-20 seconds power walk-in. Type : IGBT based full bridge Voltage Regulation : ( + ) 1% Ripple Voltage : < 2% Converter Protection : \\"Advanced Electronic Protection for device safety backed up, with MCB's/ MCCBs & fast acting fuses\\" Inverter Type : IGBT based MPWM with instantaneous Sinewave Control Output PF : 0.8 lagging to Unity Nominal Voltage : 230VAC, 16, P-N Regulation : ( + ) 1% Frequency : 50 Hz + 0.1Hz Waveform : Pure Sinewave \\"Total HarmonicDistortion\\" : Linear Load < 2% Non Linear Load < 5% Over Load Capacity : 110% 1 Minute 120% 30 Seconds Efficiency : 85 % Crest Factor 3 : 1 Isolation True Online with complete galvanic isolation. Inverter Protection \\"Advanced Electronic Protection for device safety backed up with MCB's/ MCCBs & fast acting fuses, high speed pulse by pulse electronic device protection over voltage /under voltage protection, Electronic over current trip.\\" Static Bypass : Optional Manual Bypass : Provided Alarms : ? Input / Low / Fail ? Output overload ? Over temperature ? Battery low LED Indications (Single LED with multi function ) : ? Mains ON ? UPS ON ? Battery Low ? Overload ? Input Voltage ? Output Voltage ? Load current ? Output Frequency ? Battery Voltage , Make=Hykon/numeric/GE/Eaton |
| 3 | OD181880/2024-2025:Supply and installation of 100 AH ,12V , Tubular Battery having 3 YEAR Replacement warranty. ( Make: EXIDE/AMARON/Hykon/ Equivalent). |
| 4 | OD212897/2024-2025:Supply and fixing Battery rack & Inter connecting cables |
| 5 | OD181896/2024-2025: Supply and fixing of 25 mm Corrugated PVC flexible conduit, conforming in relevant ISS or with original wiring extended including painting as required. |
| 6 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 7 | 1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm |
| 8 | 1.21.5:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm |
| 9 | 90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 10 | 90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 11 | OD212985/2024-2025:Supply and fixing 40 to 63 amps rating 240/ 415V "C" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Tripple pole |
| 12 | 2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 13 | OD25562/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 10 sq. mm |
| 14 | OD25613/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 16 sq. mm |
| 15 | OD25563/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 2x 25 sq. mm |
| 16 | 90.12.24.4:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm |
| 17 | 90.12.24.5:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.16 sq mm |
| 18 | 90.12.24.6:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.25 sq mm |
| 19 | OD25603/2025-2026:Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, color washing etc. including giving necessary connections as required. Switch disconnector unit 100A 4P AC23 A (Sheet steel enclosure) |
| 20 | 90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp |
| 21 | 9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) |
| 22 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 23 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 24 | OD25617/2025-2026:Supply and providing 12x3mm brass nut and bolt etc. as required. Please Enable Macros to View BoQ information |