Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Conversion to HT connection at Govt.ITI,Ettumanoor |
| 2 | OD203944/2024-2025:Supply, conveyance, installation, testing and commissioning of 315 KVA, 11KV/433V Indoortype unitized sub station of IP class 54, with cast resin Transformer with 11KV VCB mechanically ON/OFF on H.T.side, and TOD Meter,Metering CT and PT ,with Top/bottom entry cable box .The LTPortion Shall include 1No 630A 4 pole 50KA isolation duty type MCCB with microprocessor based release with overload setting of 50-100% with inbuilt earth fault relay suitable size Neutral CTwith MC12 Relay on L.T. side. The HT portion consists of 1No 11KV, 630A, 350MVA VCB with 2 o/c relay with high set element one E/F relay with DC trip with interlock with main switch and mechanical ON/OFF, shunt trip coil for the remote operation. TOD metering facilities consists of 3Nos....../5A (or suggested by KSEB) 15VA, 0.2class accuracy cast resin CTs, 1No 3 phase 3 Limb 11KV/110V, 10VA, 0.2 class accuracy cast resin PTs. with protective fuses. 1No TOD meter 1No TOD meter test terminal block,(TOD meter and CTs, PTs unit compartment shall be so fabricated. So as to enable the KSEB authorities to seal it) and including arranging testing and installation of the same with KSEB testing Division. Transformer Portion consists of 315 K.V.A , 11 K.V/433V,50 Hz, Delta/Star connected cast resin insulated copper wound transformer. The coreshall be made of high grade grain oriented silicon M4 steel lamination insulated andoxide layer and outside of the core shall be protected against corrosion by epoxy resinfinish. Class 'F' insulation level shall be maintained. OFF load tapchanging facility shall be incorporated so as to achieve tap positions of +5% to -10% in step of 2.5%. four channel Temperature Scanner with 4 nos Sensors, annunciatorand trip mechanism shall be provided. The Transformer shall confirm to latest IS and ECBC standards. The maximum allowable loss limited tovalues designated by ECBC Norms . All inter connection from HT Side totransformer and to LT Side shall be given using electrolytic copper bus bar insulatedwith heat shrink sleeves and tinned at the point of contacts. All internal earthconnections are to be given as per standards. Necessary protection shall be made forgiving cable connections on the HT side as well as LT side. Phase barriers andshrouding as per rules has to be given.The enclosure shall be fabricated from 2.00mm CRCA sheet, complying with of IP 54standards and shall be powder coated over a coat of Zinc chromate primer after seventank processing and phosphatizing. The USS shall be installed as per the directions atsite. |
| 3 | OD205713/2024-2025:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes in the existing masonry open duct as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments. |
| 4 | OD209549/2024-2025:Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 11 KV grade of the following sizes in ground includingexcavation of trench of size 35 x 100 cm, refilling the trench etc. as required 3 core300 sqm stranded compact circular aluminum conductor, conductors screened withextruded semi conducting compound XLPE insulated, insulation screened withextruded semi conducting compound in combination with copper tape (0.3KA for Isec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armored, andoverall PVC sheathed cable conforming to IS: 7098 part II 1985 with latestamendments. -- |
| 5 | OD205743/2024-2025:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminum power cable, 11 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 3 core 300 sqm stranded compact circular aluminum conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armored, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments. -- |
| 6 | 10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm |
| 7 | 10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit completewith all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductorcable of 11 KV grade as required :300 sq. mm |
| 8 | OD207208/2024-2025:Supply and providing cable trays or frame work of all sizes with angle iron/flat iron suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gears/Cable/machines for support , fixed to wall/floor using suitable size anchor bolts etc grouted to wall, making good the damages, colour washing etc as required |
| 9 | OD203748/2024-2025:Supply and fixing of 630 A, Enclosure type ATS unit with 4P motorized changeover with ATC controller unit and wire way kit or equivalent including auto start operation for existing DG set, all accessories including connections. |
| 10 | 90.12.7.36:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm |
| 11 | 90.12.5.36:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 300 sq mm |
| 12 | 90.12.6.36:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 300 sq mm |
| 13 | 90.12.12.6:Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation110/94 mm or nearest size |
| 14 | 90.12.9.6:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench110/94 mm or nearest size |
| 15 | 9.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm) |
| 16 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 17 | 90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 18 | 90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 19 | 90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) |
| 20 | 90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. |
| 21 | 90.14.7:Supply and providing copper earth bus in the panel board |
| 22 | OD203531/2024-2025:Supply and fixing V, A & F 3Phase meter (multi function meter) with accuracy class 1 in the existing panel assembly as required. |
| 23 | OD203692/2024-2025:Supply and fixing 150/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT in the existing panel assembly as required. |
| 24 | OD203696/2024-2025:Supply and fixing 240V AC/DC Panel Mounted LED Indication lamps , 22.5 mm cut out dia (Red, Yellow,& Green colour) in the existing panel assembly and giving connection etc. as required.. |
| 25 | OD203698/2024-2025:Supply and fix LED indicators for all voltage ranges- Blue colour |
| 26 | 90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 27 | 90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A. |
| 28 | OD206627/2024-2025:Supply and fixing one set of spreader/ terminal adapter kit Extended terminal for 4 pole MCCB of rating upto 630 Amps (8 Pcs) |
| 29 | 90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A |
| 30 | 90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 31 | 90.14.10.18:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.630A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 32 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 33 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 34 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 35 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 36 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 37 | 90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 38 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 39 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 40 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 41 | OD210270/2024-2025:Supply and fixing Emergency push button with enclosure of MS Construction in surface/recess with stainless steel chain & hammer assembly Complete with glass and push button on wall and giving connection etc. as required |
| 42 | OD206686/2024-2025:Relocation of the existing MSB from the existing room to newly constructed electrical room |
| 43 | 90.6.5.5:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 2.50 sq mm |
| 44 | 90.12.6.28:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm |
| 45 | 90.12.6.29:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 50 sq mm |
| 46 | 90.12.6.30:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 70 sq mm |
| 47 | 90.12.6.41:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm |
| 48 | 90.12.5.27:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 25 sq mm |
| 49 | 90.12.5.28:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm |
| 50 | 90.12.5.29:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm |
| 51 | 90.12.5.30:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 70 sq mm |
| 52 | 90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm |
| 53 | 90.12.7.27:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp |
| 54 | 90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp |
| 55 | 90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 56 | 90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm |
| 57 | 90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp |
| 58 | 90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 59 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 60 | 90.12.10.3:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size |
| 61 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 62 | 90.12.9.3:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size |
| 63 | 9.1.20:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm) |
| 64 | 9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) |
| 65 | 9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 66 | 9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 67 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 68 | 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 69 | OD203614/2024-2025: supplying and installation of Sheet steel Enclosure with 32A,4 Pole isolator |
| 70 | OD203533/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipment including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct, etc as required.With 1.50 sq mm wire |
| 71 | OD203850/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.10.00 sq mm wire single run |
| 72 | OD203851/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.6.00 sq mm wire single run |
| 73 | 90.14.24.11:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor, suitable for direct connection to motors. |
| 74 | 90.14.24.5:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors. |
| 75 | 90.14.24.8:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors. |
| 76 | OD203638/2024-2025:Supply and fixing 8Stage APFC controller 440/ 110 V, 5 A/ 1 A in the existing panel assembly as required. |
| 77 | OD203639/2024-2025:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 20 KVAR & with 1 NO+1NC auxiliary contact in the existing panel assembly as required. |
| 78 | OD203640/2024-2025:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 7.5-10 KVAR & with 1 NO+1NC auxiliary contact in the existing panel assembly as required. |
| 79 | OD203641/2024-2025:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 4 - 7 KVAR & with 1 NO+1NC auxiliary contact in the existing panel assembly as required. |
| 80 | OD206678/2024-2025:Supply and providing Panel mounting fresh air fan150 mm as required. |
| 81 | 1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm |
| 82 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 83 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 84 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 85 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 86 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 87 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 88 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 89 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 90 | 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture |
| 91 | 90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 92 | 90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps |
| 93 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 94 | 90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required. |
| 95 | 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 96 | OD206682/2024-2025:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.450 mm sweep heavy duty exhaust fan working on 230 V A/C 1400 rpm- |
| 97 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 98 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 99 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 100 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 101 | OD203874/2024-2025:Supply and fixing 2 x 25mm X 3 mm copper strip test joint for the earthing system. |
| 102 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 103 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 104 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 105 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 106 | OD210346/2024-2025:Supply and providing 25x3mm brass bolt |
| 107 | OD206684/2024-2025:Earthing with GI earth plate 1200X1200X12 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 108 | OD206689/2024-2025:Supply and laying the following sizes of strips laid 1.2 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil). 25 x 3 mm copper strip |
| 109 | 90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip |
| 110 | 90.16.4.8:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip |
| 111 | OD203527/2024-2025:Supply & fixing 80A to 160A HRC fuse links Size 0 |
| 112 | OD203528/2024-2025:Supply & fixing 2A to 4A,6-80 DIN type HRC fuse links Size 000 |
| 113 | OD210298/2024-2025:Supply and providing 4.5 CO2 type Fire Extinguisher with hose and clamps including fixing it to wall as required. |
| 114 | OD210300/2024-2025:Supply and providing First aid chart duly framed and placed in a conspicuous location for clear vision |
| 115 | OD210301/2024-2025:Painting letters or figures of the 2.5 cm, 4 cm or 5 cm height sizes with enamel paint as identificationmark to SB, DB, Panel board as required. |
| 116 | OD210311/2024-2025:Supply and providing MS chequered plate of suitable thickness including cutting,welding, painting etc. as required for the outdoor cat walk plat form. |
| 117 | OD74069/2025-2026:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coatof red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracketfilled with fine sand, painting the bracket/ floor stand including making good the damages,colour washing etc. as required. |
| 118 | OD74072/2025-2026:Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose andclamps including fixing it to wall as required. |
| 119 | OD210302/2024-2025:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy |
| 120 | OD210303/2024-2025:Copying charge of Electrical/fire Drawing per A3 sheet additional copies. |
| 121 | OD210521/2024-2025:Provision for correcting the existing installation as per the direction from electrical inspectorate after submitting drawing for approval and inspection (The item rate as per the present DSR with quoted variation) Non competition item App rate Rs 32200 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail