|
| 1 | APPENDIX-A -TIPPUSULTHAN WSS |
| 2 | Pipeline worksSupply of PVC Pipe, 10kg/cm2, 20mm Dia. |
| 3 | Supply of PVC Pipe, 10kg/cm2, 25mm Dia |
| 4 | Supply of PVC Pipe, 10kg/cm2, 32mm Dia. |
| 5 | Supply of PVC Pipe, 10kg/cm2, 40mm Dia. |
| 6 | Supply of PVC Pipe, 10kg/cm2, 50mm Dia. |
| 7 | Supply of PVC Pipe, 10kg/cm2, 63mm Dia. |
| 8 | Supply of PVC Pipe, 10kg/cm2, 75mm Dia. |
| 9 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 10 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock. |
| 11 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 20 mm nominal outside diameter pipes |
| 12 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 25 mm nominal outside diameter pipes. |
| 13 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 32 mm nominal outside diameter pipes. |
| 14 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 40 mm nominal outside diameter pipes. |
| 15 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 50 mm nominal outside diameter pipes. |
| 16 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes. |
| 17 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes. |
| 18 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore |
| 19 | Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 21 | Rectification of leakages of 65mm G.I. Pipes by replacing lengths up to 1.0m including earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar / concrete cutting, by cutting, removing and stacking the damaged portion from the existing line without causing any damages to the remaining portion and specials and conveying and replacing with G.I. Pipes of suitable size and jointing by thraded coupler and union of suitable size including threading, alignment, laying and jointing to make a water tight joint, testing the line to the required pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other utilities, including the charges hire and conveyance of tools, plant and materials to the leak site, bailing out water, lighting, watching, ribbon fencing,caution boards, traffic diversion, including the cost of specials but excluding cost of pipe and as per the direction of departmental officers etc., complete. |
| 22 | Engaging Coolie. |
| 23 | Engaging Fitter ( grade 1) |
| 24 | Supplying uPVC pipe specials for 20 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 25 | Supplying and laying uPVC pipe specials for 25 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 26 | Supplying uPVC pipe specials for 32 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 27 | Supplying uPVC pipe specials for 40 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 28 | Supplying uPVC pipe specials for 50 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 29 | Supplying uPVC pipe specials for 63 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 30 | Supplying uPVC pipe specials for 75 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 31 | Pumphouse & Well Maintanance workRemoving white or colour wash by scrapping and sand papering and preparing thesurface smooth including necessary repairs to scratches etc. complete |
| 32 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 33 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 34 | Lettering with black Japan pint of approved brand and manufacture |
| 35 | Tank Base Maintanance worksProviding and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 36 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 37 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 38 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 39 | Lettering with black Japan pint of approved brand and manufacture |
| 40 | Pump set InstallationPump & Motor- Supply, erection, testing and commissioning of KWA pre-qualified reputed make open well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl/ Diffuser with ISI mark. The pump shall be directly coupled to a continious rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283/ 1995 as amended thereafter, siutable for operation in AC 3 phase 380 V + /- 10%, 50 Hz + / - 5%, Duty Conditions : Discharge - 3.29 lps Total Head - 204 m Starter- Supply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitorPanel board- Supply, erection, testing and commissioning of one number open board - single sheet type control panel board, suitable for providing control system for running motor pump set, suitable capacity Main Switch, DOL starter supplied, provided with a common earth for the entire panel as per IE rules and code of practice. The panel shall be fitted on the Wall or seperate MS Support to prevent any wetness, moisture, allowing sufficient free space for wiring, air circulation in back side of board with proper support on wall or support, including necessary plastering patch works, concrete works,Cabling work- Supply, laying, testing and commissioning Flat submersible Copper Cable not below 4 sqmm for wiring between Main switch, Starter, Motor pump set considering energy conservation, including additional length allowance as loop for future repaire as per the direction of Engineer. Earthing -Supply of all materials and providing suitable earthing by using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving double earthing tomotor, starter, panel board etc. as per IE standards.Capacitor-Supply, erection, testing and commissioning of heavy dutyAPF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834Valves-Supply of suitable size best quality heavy duty ISI marked CIdouble flanged sluice valve and Non retum valve of 50 mm or dia of pumping line 1.60 PN pressure rating. Fitting of valves shall include proper RCC support for Non return valves and Sluice Valves of reputed make.Pressure Gauge-Supply of suitable size best quality heavy duty ISI marked Pressure Gauge with controll ValveSuction and delivery pipe connections-Supply and fitting of dia. not below 50 mm dia. according to pump discharge, best quality C class GI erection pipe for a total length of 10 m suitable for the above pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flanged joints to withstand the heavy load and for facilitating lifting and erection of motor) and connecting the delivery side of the pump with the valves and suitable specials, including cutting, welding, jointing to link the line with existing pumping main near well.General Conditions-Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessoriessupplied |
| 41 | Water QualityTesting water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters |
| 42 | APPENDIX B -NECHITHADAM WSS |
| 43 | Pump set InstallationPump & Motor- Supply, erection, testing and commissioning of KWA pre-qualified reputed make open well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl/ Diffuser with ISI mark. The pump shall be directly coupled to a continious rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283/ 1995 as amended thereafter, siutable for operation in AC 3 phase 380 V + /- 10%, 50 Hz + / - 5%, Duty Conditions : Discharge - 1.94 lps Total Head - 111 m Starter- Supply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitorPanel board- Supply, erection, testing and commissioning of one number open board - single sheet type control panel board, suitable for providing control system for running motor pump set, suitable capacity Main Switch, DOL starter supplied, provided with a common earth for the entire panel as per IE rules and code of practice. The panel shall be fitted on the Wall or seperate MS Support to prevent any wetness, moisture, allowing sufficient free space for wiring, air circulation in back side of board with proper support on wall or support, including necessary plastering patch works, concrete works,Cabling work- Supply, laying, testing and commissioning Flat submersible Copper Cable not below 4 sqmm for wiring between Main switch, Starter, Motor pump set considering energy conservation, including additional length allowance as loop for future repaire as per the direction of Engineer. Earthing -Supply of all materials and providing suitable earthing by using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving double earthing tomotor, starter, panel board etc. as per IE standards.Capacitor-Supply, erection, testing and commissioning of heavy dutyAPF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834Valves-Supply of suitable size best quality heavy duty ISI marked CIdouble flanged sluice valve and Non retum valve of 50 mm or dia of pumping line 1.60 PN pressure rating. Fitting of valves shall include proper RCC support for Non return valves and Sluice Valves of reputed make.Pressure Gauge-Supply of suitable size best quality heavy duty ISI marked Pressure Gauge with controll ValveSuction and delivery pipe connections-Supply and fitting of dia. not below 50 mm dia. according to pump discharge, best quality C class GI erection pipe for a total length of 10 m suitable for the above pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flanged joints to withstand the heavy load and for facilitating lifting and erection of motor) and connecting the delivery side of the pump with the valves and suitable specials, including cutting, welding, jointing to link the line with existing pumping main near well.General Conditions-Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessoriessupplied |
| 44 | Pipe LineSupply of PVC Pipe, 10kg/cm2, 20mm Dia. |
| 45 | Supply of PVC Pipe, 10kg/cm2, 25mm Dia |
| 46 | Supply of PVC Pipe, 10kg/cm2, 32mm Dia. |
| 47 | Supply of PVC Pipe, 10kg/cm2, 63mm Dia. |
| 48 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. N |
| 49 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 20 mm nominal outside diameter pipes. |
| 50 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 25 mm nominal outside diameter pipes |
| 51 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 32 mm nominal outside diameter pipes. |
| 52 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes. |
| 53 | Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. |
| 54 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 55 | Engaging Coolie. |
| 56 | Engaging Fitter ( grade 1). |
| 57 | Supplying uPVC pipe specials for 20 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 58 | Supplying uPVC pipe specials for 25 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 59 | Supplying uPVC pipe specials for 32 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 60 | Supplying uPVC pipe specials for 63 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 61 | Water Quality TestTesting water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters. Please Enable Macros to View BoQ information |