| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good any disturbed surfaces (patching holes, plastering, and painting to match existing finish). Complete as specified and directed |
| 2 | M&L replacement of point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metalic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for following :-One light/Fan point controlled by one way switch 6 Amps 240 volts |
| 3 | Ditto all as per item no.2 above but One 3 pin 6 Amps socket out let point on independent board. |
| 4 | Ditto all as per item no. 2 above but One 3 pin 6 Amps socket out let point on same board. |
| 5 | Ditto all as per item no. 2 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size. |
| 6 | Ditto all as per item no. 2 above but One light point controlled by Two 2-way switches |
| 7 | M&L replacement of point wiring with 2.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable and including surface, Non metalic rigid PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit |
| 8 | S&F in replacement PVC / polycarbonate lamp holders batten/Angle type |
| 9 | S&F in replacement modular step type fan regulator 100W, 2 module |
| 10 | S&F in replacement modular switch piano type 10 amps one way one module |
| 11 | S&F in replacement modular switch piano type 20 amps one way one module with neon indicator |
| 12 | S&F in replacement modular Socket, 6A - 2/3 pin 2 module |
| 13 | S&F in replacement modular Socket, 6/16A - 2/3 pin 2 module |
| 14 | S&F in replacement of 1 module Blanking plates complete all as specifed and directed |
| 15 | S&F in replacement modular Bell push, 10 Amp with neon indicator one module |
| 16 | S&F in replacement modular switch piano type 10 amps Two way one module |
| 17 | M&L in replacement of door bell AC 230 volts single phase ding dong type all as specified and directed. |
| 18 | S&F in replacement for white cover plate with frame 1 or 2 module. |
| 19 | S&F in replacement for white cover plate with frame 3 module. |
| 20 | S&F in replacement for white cover plate with frame 4 module. |
| 21 | S&F in replacement for white cover plate with frame 6 module. |
| 22 | S&F in replacement for white cover plate with frame 8 module. |
| 23 | S&F in replacement for white cover plate with frame 12 module. |
| 24 | S&F in replacement round plate for celing |
| 25 | Supply and fixing replacement of rigid non-metallic PVC casing capping, double lock type/PVC conduit (ISI marked) of size not less than 25mm, including all necessary accessories (e.g., bends, elbows, connectors, saddles, screws,round plate etc.) for securing loose wiring and repairing/re-routing point wiring and submain wiring, complete as specified and directed by the Engineer-in-Charge. This includes: a) Supply of 25mm or larger rigid non-metallic PVC casing capping/conduit (ISI marked). b) Supply of all necessary accessories (bends, elbows, connectors, saddles, screws, etc.).c )Securing loose wiring within the casing/conduit. d) Repairing/re-routing existing point wiring/submain wiring as needed. e) Making necessary connections and terminations.f) Testing of the wiring after completion. Notes:Rates shall include the cost of all materials, labor, tools, equipment, transportation, and any other incidental expenses required for the complete execution of the work. |
| 26 | S&F in replacement of flexible conduit pipe ivory grey/white/block in colour of dia not less than 15/25 mm complete all as specified and directed. Make: As per sample approved |
| 27 | Taking down carefully existing sub-main wiring including removal of all associated accessories such as conduits, saddles, clips, junction boxes, etc., and making good any disturbed surfaces (patching holes, plastering, and painting to match existing finish). Complete as specified and directed |
| 28 | M&L replacement of sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 1.5 Sqmm , 1100 Volts grade in and including PVC Conduit/casing caping medium grade not less than 25 mm complete with conduit accessories and copper cable 1.5 sqmm continuous earth wire complete all as specified and directed (Two runs of 1.5 Sqmm cable with 01 run of 1.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 29 | M&L replacement of sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and directed (Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 30 | M&L replacement of sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed (Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 31 | M&L replacement of sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 6 sqmm continuous earth wire complete all as specified and directed (Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 32 | M&L replacement of sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 10 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 10 sqmm continuous earth wire complete all as specified and directed (Two runs of 10 Sqmm cable with 01 run of 10 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 33 | M&L replacement of sub main wiring with Four single core PVC insulated FRLS cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed (four runs of 4 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 34 | M&L replacement of sub main wiring with Four single core PVC insulated FRLSH cables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 6 sqmm continuous earth wire complete all as specified and directed (four runs of 6 Sqmm cable with 01 run of 6 Sqmm earth wire along with casing caping/conduit shall be measured as one RM) |
| 35 | S&F in replacement of 1100 volts grade heavy duty service cable 4 Sqmm two core PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed including PVC Conduit ISI Marked 20mm including all necessary bends, couplings, tees, and other accessories.Surface Saddling of PVC Conduit on Wall using approved saddles and fixing screws. Spacing as per specifications ( 1-meter intervals).complete all as specified |
| 36 | S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified (Make/Model of VTPN DB : Legrand/L&T/C&S) Note:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule |
| 37 | S&F in replacement MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed by the Engr-in-Charge. Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. |
| 38 | Dittto all as per item no 47 above but 08 way SPN DB (Double door) |
| 39 | Dittto all as per item no 47 above but 04 way SPN DB (Single door) |
| 40 | Dittto all as per item no 47 above but 04 way SPN DB (Double door) |
| 41 | Dittto all as per item no 47 above but 02 way SPN DB (Single door) |
| 42 | S&F of MCCB with rating of 125 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu).MCCB should be with suitable spreaders and phase barriers for each terminals. |
| 43 | S&F of MCCB with rating of 63 to 100 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu).MCCB should be with suitable spreaders and phase barriers for each terminals. |
| 44 | S&F of C Curve MCB SP 6-32 Amps working on 240 volts,50 Hz 10 KA all as specified and directed. |
| 45 | S&F of C Curve MCB DP 6-32 Amps working on 240 volts,50 Hz 10 KA all as specified and directed. |
| 46 | S&F of C Curve MCB SPN 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed. |
| 47 | S&F of C Curve MCB TP 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed. |
| 48 | Supply and fix of C Curve MCB TPN 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed. |
| 49 | S&F in replacement sheet metal enclosures Single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts complete with all accessaries etc all as directed |
| 50 | S&F in replacement sheet metal enclosures Triple pole and earth encolsure with a three pin and earth plug withsocket complete with one triple pole MCB 32 Amps, 240 volts complete with all accessaries etc all as directed |
| 51 | M&L for replacement of earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed |
| 52 | S&F in replacement of GI pipe bracket of 25 to 40 mm dia 1 mtr long bend to shape for street light fitting made out of 25 to 40 mm dia GI light grade pipe fixed on building/pole using suitable FI clamp including necessary new nut, bolt and washer complete all as specified and directed. |
| 53 | S&F in replacement LED building security light fiitting 30 W, IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC cover having TOP opening seperate driver compartment complete all as specified and directed Make- Luker LEST30NS/ Havells / Wipro / Halonix/Benlo |
| 54 | S&F in replacement LED building security light fiitting 100 W, IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC cover having TOP opening seperate driver compartment complete all as specified and directedMake- Luker LEST100NS/ Havells / Wipro / Halonix/Benlo |
| 55 | S&F in replacement of 12 watt,230V surface and wall mounted white LED Mirror Light including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed by Engr-in-charge.Make- Luker LIMR13 3-IN-1 / or equivalent inHavells / Wipro / Halonix/Benlo |
| 56 | S&F in replacement of 20watt,230V WH/WW surface and wall mounted LED batten, extruded polycarbonate housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified.Make- Luker LT520P/ Havells / Wipro / Halonix/Benlo |
| 57 | S&F in replacement of 10watt,230V WH/WW surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified.Make- Luker LT510P / Havells / Wipro / Halonix/Benlo |
| 58 | S&F in replacement 12 watt, 230V WH/WW surface mounted LED downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency, including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified . Make - Luker Cat part no. LEPSRR12/LEPSRS12/Halonix/Havells / Wipro / Halonix/Benlo |
| 59 | S&F in repalcement surface/recess mounted 2' x 2' LED Panel lights 40 W LED 5700K, 240Volts WH/WW and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver.Make: Luker Cat Part: LKMSRS40/ Halonix/Havells / Wipro / Halonix/Benlo |
| 60 | S&F in repalcement COB light 12W LED Tiltable surface mounting and Environmental friendly, new generation, energy saving, decorative all as specified and directed. Make: Luker cat part no. LCOBSP12 or equivalent in Havells / Wipro / Halonix/Benlo |
| 61 | S&F in repalcement wall decorative light 9W with lamp WH/WW surface mounting and Environmental friendly, new generation, energy saving, decorative all as specified and directed. Make: Luker cat part no. LWLA3E27 BK or equivalent in Havells / Wipro / Halonix/Benlo |
| 62 | Dismantling and removing rusted louvers suitable for 150/230/300/450/600 mm sweep exhaust fan S&F in replacement of MS louvers duly painted gray coloured suitable for 150/230/300/450/600 mm heavy duty exhaust fan alongwith four number mounting bracket with bolts, nuts washers etc complete all as directed. |
| 63 | S&F in replacement of GI pipe ceiling fan down rod of 15 mm dia up to 1 mtr long for ceiling fan made out of 15 mm dia GI heavy grade pipe fixed on ceiling using suitable clamp including necessary new nut, bolt and washer complete all as specified and directed. |
| 64 | Taking down ceiling fan/exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as directed.Note : 1.Cost of spares such as capacitors, bearings etc will be measured and paid for separately under respective Item of sch A as supply only. |
| 65 | Supply only capacitor of 2.5/4 mfd for ceiling fan/exhaust fan. |
| 66 | Supply only bearing No.6201/6202/6203 or any other No matching to the existing size and suitable for Ceiling fan exhaust fan/wall mounted fan. Make:SKF/NBC |
| 67 | Supply only 9 WW/WH LED Lamp for E27/B22 Holders. Make:Luker/ Halonix/Havells / Wipro / Halonix/Benlo |
| 68 | Supply and Installation of 3mm thick Aluminum Composite Panel (ACP) Cladding for wiring cables, including all necessary materials and labor, as specified and directed by the Engineer-in-Charge. This includes: 3mm thick ACP sheets. 1/1.5mm aluminum pipe framework . Necessary hardware including drilling, iron screws, double-sided tape, silicone sealant, dowels, masking tape, etc. All labor for fabrication, installation, cutting, fixing, jointing, and finishing of the ACP cladding, including the framework. Waste disposal and site cleanup related to the cladding work etc complete all as specified and directed. Notes: Rates shall include the cost of all materials, labor, tools, equipment, scaffolding (if required), transportation, and any other incidental expenses required for the complete execution of the work. |
| 69 | S&F indoor/outdoor LED Strip of 220 v Linear flex in colour WW,with fixing tape and end cap and suitable driver and connector of suitable and IP 65 Protection complete ,single phase,mounting on the ceiling/wall/piller as reqd at the site complete all as specified and directed . Make;Jaguar/Philips/Havells/Bajaj. Please Enable Macros to View BoQ information |