| 1 | Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe etc and getting out in hard soil, complete all as specified and directed. |
| 2 | M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Par-I, all as specified and directed. |
| 3 | Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 flate size 250mm x 150mm x 40mm, complete all as specified and directed |
| 4 | Labour only for laying of old serviceable cable covers retrieved from excavation complete all as specified and as directed by Engineer-in-Charge. |
| 5 | M & L for returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. |
| 6 | M & L for removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and/or as directed by Engineer-in-Charge. |
| 7 | Supply, laying and testing of XLPE insulated, armoured, haeavy duty electric cable with stranded aluminium conductor rating 1100 volts grade of size 6 Sqmm 2.0 core laid in trences or passing through pipes ducts or fixed to walls/poles including taking down old unserviceable cable and cable covers, complete all as specified and as directed by Engineer-in-Charge. Note :- Excavation and earth work shall be measured and paid separately under respective item. |
| 8 | Supply and lay XLPE insulated, armoured, haeavy duty electric cables with stranded aluminium conductor rating 1100 volts grade of size 10 Sqmm 2.0 core laid in trences or passing through pipes.ducts or fixed to walls/poles including taking down old unserviceable cable and cable covers complete all as specified and as directed by Engineer-in-Charge.Note :- Excavation and earth work shall be measured and paid separately under respective item. |
| 9 | Taking down old unserviceable building security light and supply and fix security light fitiing 35 watt 230 Volt AC outdoor type with hiugh pressure die cast aluminium hiusing and heat resistant complte with driver, lamp cracket with impact and corosion resistant including thermal management in multiple optics with IP65/66 protection, complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Taking down old unserviceable building security light and supply and fix security light fitiing 60 watt 230 Volt AC outdoor type with hiugh pressure die cast aluminium hiusing and heat resistant complte with driver,lamp cracket with impact and corosion resistant including thermal management in multiple optics with IP65/66 protection complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Taking down old unserviceable building security light and supply and fix security light fitiing 90 watt 230 Volt AC outdoor type with hiugh pressure die cast aluminium hiusing and heat resistant complte with driver,lamp cracket with impact and corosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Taking down old unserviceable flood light & supply and fixing LED flood light fitting 50 watt 230V AC outdoor type with thermal management in multipale optics and equipped with IP 66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Taking down old unserrviceable flood light & supply and fix LED flood light fitting 100 watt 230V AC outdoor type with thermal management in multipale optics and equipped with IP 66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Taking down old unserrviceable flood light & supply and fix LED flood light fitting 120 watt 230V AC outdoor type with thermal management in multipale optics and equipped with IP 66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Taking down old unserviceable street light and supply and fix street light fitiing 70 watt 230 Volt AC outdoor type with hiugh pressure die cast aluminium hiusing and heat resistant complte with driver,lamp cracket with impact and corosion resistant including thermal management in multiple optics with IP65/66 protection complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Taking down old unserviceable street light and supply and fix street light fitiing 100 watt 230 Volt AC outdoor type with hiugh pressure die cast aluminium hiusing and heat resistant complte with driver,lamp cracket with impact and corosion resistant including thermal management in multiple optics with IP65/66 protection complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Taking down old unserviceable building street light and supply and fix street light fitiing 120 watt 230 Volt AC outdoor type with hiugh pressure die cast aluminium hiusing and heat resistant complte with driver,lamp cracket with impact and corosion resistant including thermal management in multiple optics with IP65/66 protection complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Taking down old unserviceable light & supply and fix LED down light ( round, Coll white ) of capacity 15 Watt, motion sensing based with 4.5 mtrs radius, 215 Volts complete all as specified annd directed. |
| 19 | Supply and fix in replacement PVC insulated round flexible copper conductor 2.5 sqmm 2.0 core coper conductor 1100 volts grade complete all as specified and directed. |
| 20 | Taking down old unsereviceable looping box and supply and fix FR/PVC pole junction box for loop out of size 200 x 180 mm including 3 pole and neutral with bakelite connector and one SP MCB 10 Amps and necessary fixing arrangement complete all as specified and directed. |
| 21 | Supply and fix in replacement bracket for security light made up of 40mm dia, 0.6 metre long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed. |
| 22 | Taking dowon old unserviceable street light timer and supply and fix street timer set three phase 25KW workingn based on astronomical timer along with contractor, MCCB, ON/OFF switch, Manual/automatic selector switch in enclosure and mounting bracket, nut bolts, washer complete all as specified and/or as directed by Engineer-in-Charge. |
| 23 | Deduct Schedule of Credit of Rs (-) 50470.00 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |