| 1 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 2 | M&L for broken bicks hardcore of guage exc 63mm but not exc. 100mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rolled/rammed to a true surface complete all as specified and directed . |
| 3 | M&L for 50mm thick cement concrete type B-2, 1:2:4 ,40mm graded crushed stone aggregate in sub-floors, sub-bases, floors and pavings etc. Complete all as specified and directed . |
| 4 | M&L for 18-20mm thick granite stone slab of machine cut mirror polished in flooring , bedded and jointed with grey cementpaste and pointed with white cement with admixture of pigment to match the shade of granite stone including 15mm thick screed bed in CM 1:4 complete all as specified. |
| 5 | M & L for 18-20mm thick granite stone slab machine cut mirror polished in skirting/dado and jointed with grey cement paste and pointed with white cement with admixture of pigment to match the shade of granite stone and including 10 mm thick backing coat in CM 1:3 complete all as specified. |
| 6 | M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished the surface even and smooth with out using extra cement complete all as specified. |
| 7 | M & L for rendering 15mm thick on of brick work or concrete surfaces in cement mortar 1:6 finished the surface even and smooth with out using extra cement complete all as specified. |
| 8 | M & L for preparing new plastered surfaces of walls applying wall care putty not less than 2 mm thick over a coat of alkali resistant primer and applying two coats of oil emelsion distemper over a coat of alkali resistant primer complete all as specified and directed. |
| 9 | M&L for preparation of new plaster surface of walls and applying two coat of cement based paint over a coat of complete all as specified and directed by Engr-in-charge. |
| 10 | Supply and fix plain ceiling system consisting of 600 mm x 600mm tiles (As per IS: 2095-1996: Part I) of pre coated galvanised aluminium in 0.7 mm thickness in required colour to be laid “on Armstrong/Hunter Duoglas grid systems/equivalent make with 15 mm wide T - section flanges in required colour having rotary stitching on the 1200 mm & 600 mm cross tees. The grid should be GI of make “Armstrong/Gyproc /equivalent make ”with 15mm wide T - section flanges in required colour shade having rotary stitching on all T sections i.e. the main runner, 1200 mm & 600 mm. Tees with a web height of 32 mm. Perimeter trim to be Armstrong/Gyproc /equivalent make as specified in Appx 'B' of PS hereinafter, wall angles of size 19x19mm, secured to walls at 450 mm maximum centres including necessary fitting and 4 mm b GI suspenders fixed to slab using 12 mm dia fancy type steel anchor fastner hook 80 mm long in ceiling all as specified and directed. |
| 11 | S&F 8 mm thick 600x600mm size gypsum prelaminated tiles false ceiling complete all as specified and directed. |
| 12 | M&L for cutting chases, pinning in brick walls , making good to facings where required and pointing in cement mortar 1:3 for fixing of CGI in walls etc, and making good, cutting exceeding 20cm in girth complete all as specified and directed. |
| 13 | M & L PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in roof kerbs mud stops, rounded or chamfered on edges surface finished even and smooth with out using extra cement complete all as specified and directed |
| 14 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 15 | S&F steel tubes for structural purposes as in columns, main or cross beams, hip & jack rafters; purlins where connected to common rafters; fixed with angle cleats/fasteners or other connecting plates, conforming to IS:1161-1979, complete all as specified and directed. |
| 16 | S&F 8 to 10mm thick plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment also fixing with fabrication/ welding etc.of Gde Fe410 complete all as specified and directed. |
| 17 | M7l for preperation of new steelor iorn surfcae exceeding 10 cm width or grith of any description applying two coats of synthetic enamel paintover one coat of red oxide, zinc chrome primer complete all as specified and directed. |
| 18 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed . |
| 19 | S&F 1.25mm thick plain, galvanised, mild steel sheeting for iron gates including welding etc complete all as specified and directed by Engr-in-charge. |
| 20 | M&L for cement concrete type C2 1:3:6 40mm graded crushed stone aggregate including foundation filling and mass concrete complete all as specified and directed. |
| 21 | Supply and fixing Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, completeall as specified and directed. |
| 22 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. |
| 23 | S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, etc complete all as specified and directed Please Enable Macros to View BoQ information |
| 24 | S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, etc complete all as specified and directed Please Enable Macros to View BoQ information |