| 1 | Dismantling of plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed by Engr-in-Charge. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge. |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls fixed with self tapping screws , complete all as specified and directed by Engr-in-Charge. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge. |
| 5 | S&F Rolled Mild steel of grade Fe 410 -W (GdeE- 250) equal Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated complete all as specified and directed by Engr-in-Charge. |
| 6 | Dismantling of floor hearth and wall tilling including cement mortar bedding (but not backing) and removing rubbish off the premises., complete all as specified and directed by Engr-in-Charge. |
| 7 | Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15cm thickness below or above ground level, complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for 75mm thick, plain cement concrete, type C-2 1:3:6 (using 40mm graded stone aggregate) as in plinth protection work and similar, surface finished even and rough to receive floor topping, complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for PCC 1:2:4 Type B-1 (using 20mm graded stone aggregate) as in coping, kneelers, kerbs, water troughs, and the like weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engr-in-Charge. |
| 10 | S&F for formwork to edges of concrete flats for fair finish treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed by Engr-in-Charge. |
| 11 | Demolition of Brickwork or stone/boulders masonry built in cement mortar complete all as specified and as directed by the Engr-in-charge. |
| 12 | M&L for precast cement concrete type C1 1:3:6 (using 20mm graded aggregate) block masonry with soild block, exc 10cm width and setting in cement mortor 1:6 complete all as specified and as directed by Engr-in-Charge. |
| 13 | M&L for 75mm thick, plain cement concrete, type D-2 1:4:8 (using 40mm graded stone aggregate) as in sub base flooring, surface finished even and rough to receive floor topping, complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for 25mm thick PCC type B-0 (12.5mm graded stone aggregate) 1:2:4 as in floor complete all as specified and directed by the Engg-in-Charge. |
| 15 | M&L for anti-skid endura matt finished 10mm thick of premium quality, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15 mm thick screed bed in CM 1:4, complete all as specified and directed by the Engg-in-Charge. Please Enable Macros to View BoQ information |
| 16 | M&L for anti-skid endura matt finished 10mm thick of premium quality, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15 mm thick screed bed in CM 1:4, complete all as specified and directed by the Engg-in-Charge. Please Enable Macros to View BoQ information |