| 1 | Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc complete all as directed |
| 2 | M&L for brick work with old size flyash bricks, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified and as directed |
| 3 | M&L for brickwork with subclass `B` bricks, old size, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed |
| 4 | Taking down cement plaster or cement lime plaster on brick,concrete or stone surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed |
| 5 | M&L for 5 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling including finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
| 6 | M&L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls including finished the surface even and smooth without using extra cement complete all as specified and as directed. |
| 7 | M&L for 15 mm thick plaster in cement mortar (1:4) on brick or concrete surfaces including finished the surfaces even and smooth (without using extra cement) mixed with WPC as per manufacture instructions complete all as specified and as directed. |
| 8 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed. |
| 9 | M&L for preparation of newly plastered surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed |
| 10 | M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified and as directed |
| 11 | M&L for providing 3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform all as specified and as directed. |
| 12 | M&L for providing 3mm thick wall care putty on ceiling before applying oil bound distemper and making the surface uniform all as specified and as directed. |
| 13 | Taking down shutters of any description not exceeding 1 Sq. m each, from chowkhat, complete all as specified and as directed |
| 14 | Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each, from chowkhat, complete all as specified and as directed |
| 15 | Taking down Chowkhats with shutters without taking of shutter from the frame of any description not exceeding 1.50 Sq. m each, complete all as specified and as directed |
| 16 | Taking down Chowkhats with shutters without taking of shutter from the frame of any description exceeding 1.50 Sq. m but not exceeding 4.00 Sq. m each, and making good the disturbed Surface in CM 1:4 & finished with similar specification as exists, complete all as specified and as directed |
| 17 | S&F Pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with and including back filling with PCC (1:3:6), type C-0, complete as specified and as directed. |
| 18 | S&F Pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with and including back filling PCC (1:3:6), type C-0, complete as specified. |
| 19 | S&F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided in to squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamferesd or rounded, fitted with cut and mitred beads for securing glass etc., for windows and ventilators, etc are provided with stiles and rails as specified in SSR Pt I Section 8, clause 8.24 (a)complete all as specified and as directed |
| 20 | S&F flush shutters 30 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and as directed. |
| 21 | S&F for Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single side prelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of single side prelaminated PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site as per specification complete all as specified and as directed by Engineer-in-Charge. |
| 22 | S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet & reinforced with MS square tube and fixing in opening as specification & drawing, complete all as specified and as directed. |
| 23 | S&F powder coated anodized aluminum frame for partition, doors, windows, ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 24 | S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm long hinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified and as directed. |
| 25 | S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed. |
| 26 | S&F Powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 27 | M & L for PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in padding, coping, bed plates, hold fast blocks, etc., including formwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 28 | M&L Cement concrete 1:3:6 type C–1 (using 20 mm graded stone aggregate) as in filling of pressed steel door frame and hold fast blocks etc all as specified and as directed. |
| 29 | S&F Mild steel butt hinges medium weight, cold rolled, 100 mm, ISI marked, complete all as specified and as directed. |
| 30 | S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete. |
| 31 | S&F 200 mm aluminium anodized, barrel tower bolts of extruded section. |
| 32 | S&F 150mm size aluminum handle fabricated, 'D' type, anodized ISI marked complete all as specified and as directed. |
| 33 | S&F in repair 200 mm aluminium anodized, barrel tower bolts of extruded section. |
| 34 | S&F in repair 250mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy complete. |
| 35 | S&F in repair 150 mm long, Aluminum anodised floor door stopper alloy body and tounge, anodised, with hard drawn steel spring fixed in floor in repairs complete as specified and as directed. |
| 36 | S&F in repair steel helical door spring 300mm ordinary rat rail rod pattern springs including roller plate complete all as specified and as directed. |
| 37 | S&F in repair door seal bottom with aluminium plate and rubber insulation 42'' x 1.5'' complete all as specified and as directed. |
| 38 | S&F in repair for aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed. |
| 39 | S&F in repair 25 mm outer dia medium weight pipe made out of stainless steel 304 grade, including decorative ornamental knobs at both ends and one set of ornamental decorative Stainless steel clamps to fixed to walls complete all as specified and as directed |
| 40 | S&F 15 mm outer dia stainless steel rode 1mm thick, with bracket for ward robe including full threaded steel screws complete all as specified and as directed |
| 41 | M & L for preparation of new painted surfaces of wood and wood based materials of any description not other wise described over 10 cm width or girth and applying Two coat of synthetic enamel paint over a pink primer coat complete all as specified and as directed |
| 42 | M&L Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamelled paint over one coat of red oxide primer. |
| 43 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed. |
| 44 | S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed. |
| 45 | S&F for 4.8/5.0 mm thick sheet glass ordinary quality and glazing each pane n exc 0.50 Sqm fixed with neoprene rubber gasket in aluminium frame work complete all as specified and as directed. |
| 46 | Dismantling of boarding of any description, fixed in any position with nails |
| 47 | S&F 18 mm thick Rajshri WPC celluka ply of plain colour fixed with screws solvent cement/adhesive to make kitchen cabinet sides top and bottom and shelves inside the cabinets complete all as specified and as directed. Make :- Rajshri Plastiwood/Equivalent) |
| 48 | S&F 18 mm thick Rajshri WPC celluka ply of one side Prelam/Rigidlam and other side balancing laminate colour to make Kitchen cabinet shutter/drawer front shutters complete all as specified and as directed. Make :- Rajshri Plastiwood/Equivalent) |
| 49 | S&F 12 mm thick Rajshri WPC celluka ply of plain white colour fixed with screws, solvent cement/adhesive to make wall mount kitchen cabinet back and pull out drawer sides complete all as specified and as directed. Make :- Rajshri Plastiwood/Equivalent) |
| 50 | S&F in repair of auto closing hinges openable at 0 degree for kitchen cabinet shutters complete all as specified and as directed and directed. (Make : Hettich, Ebco, Prime or equivalent) |
| 51 | S&F in repair stainless steel handle 100mm size of kitchen cabinet/ cupboard shutters complete all as specified and as directed and directed (Make : Hettich, Ebco, Prime or equivalent) |
| 52 | Taking down wall panelling and similar work all as specified and as directed. |
| 53 | S&F for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame, fillet etc. as per specifications and drawing complete all as specified and as directed. |
| 54 | S&F for solid colour wood grain printed PVC sheets 5mm thick as in wall panelling inclusive of solvent cement incl necesssary PVC frame work, fillet etc. for fixing on brick or concrete wall as per specification and drawing complete all as specified and as directed |
| 55 | Dismantling mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 56 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 57 | Excavation in Post Holes ( or similar holes) each not exceeding 0.5 Cum and getting out in hard/dense soil, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed |
| 58 | M&L for providing PCC 1:3:6, type C2, using 40mm graded stone aggregate as in foundation filling and mass concrete including necessary form work complete all as specified and as directed |
| 59 | S/F Joist, channel, angle or tee sections, post fixed independently, without connecting plates, etc(cut to ordinary lengths i.e within 20mm of the length indicated quality conforming to Fe 410-W(gde-E-250)quality-A |
| 60 | S&F for MS flat iron fillets in posts and struts in fencing ,drilling holes (for securing wire mesh etc),including necessary drilling ,bolting or riveting etc confirming to Fe 410-0 or fe 310-0 |
| 61 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other,or screwed both ends,each screwed and to be fitted with washer and the hexogonel or square nut dia 5 to 10 mm not exc 5cm long complete all as specified and as directed |
| 62 | Fixing only chain link fencing including linewires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire |
| 63 | Supply only Chain link MS galvanisd fencing, any size or type |
| 64 | S&F MS round bar 10 mm dia fixed independently including hooking ends for chain link fencing conforming to Fe 290 Gde E-165 complete all as specified and as directed |
| 65 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) all as specified and as directed. |
| 66 | M & L 75 mm thick, plain cement concrete 1:2:4, type B1, using 20 mm graded crushed stone aggregates, as in sub base of flooring and finishing cement concrete surface finished even and smooth without using extra cement, complete all as specified and as directed. |
| 67 | M&L for Grouting by wrapping all pipes insert with a two way adhesion tape of make Dr. Fixit Bathseal tape/Dr. Fixit Bonding agent and grounting the gaps space with non-shrink grout Dr. Fixit Pidigrout 10M or PMM prepared by polymer modified motar with Dr. Fixit Pidicrete URP in the ratio of 1:3 by adding polymer 10% by weight of the cement & M&L for two coats of CFTRI approved waterproof coating with high performance two component pre-packed cementitious waterproofing Dr. Fixit Fastflex, with a mix ratio of (liquid : Powder), parts by wt 1:1.4 @ 0.42-0.50 Sqm/Kg to achieve 1 mm DFTover the floor surface & wall surface upto full height as per the manufracture;s instructions . All the coats to be applied in right angle to each other an interval of 4-6 Hrs including proper surface preparation as per manufracture's specification, cleaning, removal of loose concrete and filling cracks with polymer modified motar using SBR Latex Dr. Fixit Pidicrete URP. Provide and lay 45 GSM glass fibre mesh over the angle fillet when the first coat in still wet. Allow the coating to air cure for 5 days before conducting water ponding test for 24 hrs. |
| 68 | M & L 100mm thick cement concrete type D2, 1:4:8 (Using 40mm graded stone aggregate) as in sub base including use of necessary form work. |
| 69 | M&L for 40mm thick PCC 1:2:4, type B1, using 20mm graded aggregate as in floor finished even and smooth without using extra cement including use of necessary form work. |
| 70 | M&L for 100 mm thick Cement concrete type C1, 1:3:6 (using 40 mm graded aggregate) in foothpaths and hard standing finish even and fair without using extra cement complete all as specified and as directed. |
| 71 | M&L for plain cement concrete type-C2 1:3:6 (40mm garaded agg.) in surface channel and drains complete all as specified and as directed |
| 72 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, incl forms, moulds, mitred / stopped ends etc, complete all as specified and as directed. |
| 73 | M & L for 38mm wide glass dividing strips, 3mm thick, inserted in position, conforming to design complete all as specified and as directed |
| 74 | Supply only intergral water proofing compound ISI Marked complete all as specified and as directed |
| 75 | M&L for preparation(complete removal of existing treatment) of old decorated external Roof sheet/wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over priming coat premium quality on wall/roof top surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engr-In-Charge in stage passing register before applying the finishes coat.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. |
| 76 | M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible , filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper over a coat of primer on walls/ceiling including applying 1-2mm thick wall care putty over disturbed surface complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. |
| 77 | M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality on wall/ceiling surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed.Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. |
| 78 | M&L for preparation of old surfaces of walls by washing rubbing down and stopping of surface and applying one coats of cement base paint complete all as specified and directed. Make of Cement Base paint : SNOWCEM/ASIANAINTS/DUROCEM /BERGER |
| 79 | M&L for preparation of old treated plastered or unplastered surfaces of walls including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) on walls complete . |
| 80 | M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 81 | M&L for preparing old painted surfaces of steel and iron surfaces over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. Please Enable Macros to View BoQ information |