Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #54431281

Tender For Replacement Of Ceiling Plastering With Two Coat Putty For 9 Schools In Thiruverumbur

Issued by Local Bodies · Thiruverumbur, Tamil Nadu
Tender Value
14.28 Lakhs
Estimated cost
Bid Submission
06 Mar 2026
0 days left
EMD
14500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruverumbur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Replacement Of Ceiling Plastering With Two Coat Putty For 9 Schools In Thiruverumbur

BOQ

Name of Work:- RBM+GF+PAR 2025-2026
Sl. No. Item Description
1Replacement of Ceiling Plastering with two Coat Putty for PUE School Building in Poigaikudi in Asoor Panchayat.
2Chipping of Pressed Tiles & Weathering Course
3Chipping of concrete and roughening the surface
4Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone M.Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
5Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHAcertified Waterproofing coating with flutyne protectiontechnology, single component, cold applied, waterbased acrylic and UV resistant water proofingtreatment to the Existing Roof having Tile or anynon-porous surface applied @ 1.5 l/m2 in 2 coats toachieve 1mm DFT, having tensile strength with 45gsm glass fibre mesh 4N/mm2 confirming to ASTM D412; Elongation at break ≥ 300% and Crack bridgingability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability @5 bar – Nil as per EN12390- 8:2019, including surface preparation, priming thesurface with single component high-performancewaterborne tile primer which is suitable for non -porous surface at a rate of 0.14 L/m2 and spreading 45gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwichedbetween the first and second coat completely as perspecification. The finished cost to include surfacepreparation, making coving at Junction, treatment ofcracks completely as per specification.
6Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc
7Oilbound Distember two coats over priming coat with white cement.
8Replacement of Ceiling Plastering with two Coat Putty for PUE School Building in Elanthanpatty in Kanthalur Panchayat.
9Chipping of Pressed Tiles & Weathering Course
10Chipping of concrete and roughening the surface
11Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone M.Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
12Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHAcertified Waterproofing coating with flutyne protectiontechnology, single component, cold applied, waterbased acrylic and UV resistant water proofingtreatment to the Existing Roof having Tile or anynon-porous surface applied @ 1.5 l/m2 in 2 coats toachieve 1mm DFT, having tensile strength with 45gsm glass fibre mesh 4N/mm2 confirming to ASTM D412; Elongation at break ≥ 300% and Crack bridgingability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability @5 bar – Nil as per EN12390- 8:2019, including surface preparation, priming thesurface with single component high-performancewaterborne tile primer which is suitable for non -porous surface at a rate of 0.14 L/m2 and spreading 45gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwichedbetween the first and second coat completely as perspecification. The finished cost to include surfacepreparation, making coving at Junction, treatment ofcracks completely as per specification.
13Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc
14Oilbound Distember two coats over priming coat with white cement.
15Replacement of Ceiling Plastering with two Coat Putty for PUE School Building facing in Elanthanpatty Building 2 in Kanthalur Panchayat.
16Chipping of Pressed Tiles & Weathering Course
17Chipping of concrete and roughening the surface
18Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone M.Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
19Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHAcertified Waterproofing coating with flutyne protectiontechnology, single component, cold applied, waterbased acrylic and UV resistant water proofingtreatment to the Existing Roof having Tile or anynon-porous surface applied @ 1.5 l/m2 in 2 coats toachieve 1mm DFT, having tensile strength with 45gsm glass fibre mesh 4N/mm2 confirming to ASTM D412; Elongation at break ≥ 300% and Crack bridgingability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability @5 bar – Nil as per EN12390- 8:2019, including surface preparation, priming thesurface with single component high-performancewaterborne tile primer which is suitable for non -porous surface at a rate of 0.14 L/m2 and spreading 45gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwichedbetween the first and second coat completely as perspecification. The finished cost to include surfacepreparation, making coving at Junction, treatment ofcracks completely as per specification.
20Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc
21Oilbound Distember two coats over priming coat with white cement.
22Replacement of Ceiling Plastering with two Coat Putty for PUE School Building in Kumbakudi Panchayat.
23Chipping of Pressed Tiles & Weathering Course
24Chipping of concrete and roughening the surface
25Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs,beams,sunshades,facia, canopy slab,staircasewaist slab,landing slab etc.,with cement mortor 1:3(one cement and three p.sand )10mm thick including all
26Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone M.Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
27Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHAcertified Waterproofing coating with flutyne protectiontechnology, single component, cold applied, waterbased acrylic and UV resistant water proofingtreatment to the Existing Roof having Tile or anynon-porous surface applied @ 1.5 l/m2 in 2 coats toachieve 1mm DFT, having tensile strength with 45gsm glass fibre mesh 4N/mm2 confirming to ASTM D412; Elongation at break ≥ 300% and Crack bridgingability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability @5 bar – Nil as per EN12390- 8:2019, including surface preparation, priming thesurface with single component high-performancewaterborne tile primer which is suitable for non -porous surface at a rate of 0.14 L/m2 and spreading 45gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwichedbetween the first and second coat completely as perspecification. The finished cost to include surfacepreparation, making coving at Junction, treatment ofcracks completely as per specification.
28Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc
29Oilbound Distember two coats over priming coat with white cement.
30Replacement of Ceiling Plastering with two Coat Putty for PUM School Building at Navalpattu South in Navalpattu Panchayat.
31Chipping of concrete and roughening the surface
32Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHAcertified Waterproofing coating with flutyne protectiontechnology, single component, cold applied, waterbased acrylic and UV resistant water proofingtreatment to the Existing Roof having Tile or anynon-porous surface applied @ 1.5 l/m2 in 2 coats toachieve 1mm DFT, having tensile strength with 45gsm glass fibre mesh 4N/mm2 confirming to ASTM D412; Elongation at break ≥ 300% and Crack bridgingability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability @5 bar – Nil as per EN12390- 8:2019, including surface preparation, priming thesurface with single component high-performancewaterborne tile primer which is suitable for non -porous surface at a rate of 0.14 L/m2 and spreading 45gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwichedbetween the first and second coat completely as perspecification. The finished cost to include surfacepreparation, making coving at Junction, treatment ofcracks completely as per specification.
33Chipping and Removing Damaged Loose plastering and concrete, cleaning the surface and removing the rust in reinforcement rods using rust remover, fixing steel rods wherever required and applying 1 coat of Zinc rich, anti corrosive epoxy coating over the steel rods and apply 1 coat of SBR polymer latex slurry coat as bonding agent for bonding with the old surface and plastering the surface with polymer modified mortar mixed with SBR 1 Litre per bag of cement
34Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc
35Oilbound Distember two coats over priming coat with white cement.
36Replacement of Ceiling Plastering with two Coat Putty for PUM School Building at Navalpattu North in Navalpattu Panchayat.
37Chipping of concrete and roughening the surface
38Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHAcertified Waterproofing coating with flutyne protectiontechnology, single component, cold applied, waterbased acrylic and UV resistant water proofingtreatment to the Existing Roof having Tile or anynon-porous surface applied @ 1.5 l/m2 in 2 coats toachieve 1mm DFT, having tensile strength with 45gsm glass fibre mesh 4N/mm2 confirming to ASTM D412; Elongation at break ≥ 300% and Crack bridgingability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability @5 bar – Nil as per EN12390- 8:2019, including surface preparation, priming thesurface with single component high-performancewaterborne tile primer which is suitable for non -porous surface at a rate of 0.14 L/m2 and spreading 45gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwichedbetween the first and second coat completely as perspecification. The finished cost to include surfacepreparation, making coving at Junction, treatment ofcracks completely as per specification.
39Chipping and Removing Damaged Loose plastering and concrete, cleaning the surface and removing the rust in reinforcement rods using rust remover, fixing steel rods wherever required and applying 1 coat of Zinc rich, anti corrosive epoxy coating over the steel rods and apply 1 coat of SBR polymer latex slurry coat as bonding agent for bonding with the old surface and plastering the surface with polymer modified mortar mixed with SBR 1 Litre per bag of cement
40Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc
41Oilbound Distember two coats over priming coat with white cement.
42Replacement of Ceiling Plastering with two Coat Putty for PUESchool Building at bhakthavachalam nagar in Navalpattu panchayat
43chipping of pressed tiles & weathering course
44Chipping of concrete and roughening the surface
45Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone M.Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
46Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHAcertified Waterproofing coating with flutyne protectiontechnology, single component, cold applied, waterbased acrylic and UV resistant water proofingtreatment to the Existing Roof having Tile or anynon-porous surface applied @ 1.5 l/m2 in 2 coats toachieve 1mm DFT, having tensile strength with 45gsm glass fibre mesh 4N/mm2 confirming to ASTM D412; Elongation at break ≥ 300% and Crack bridgingability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability @5 bar – Nil as per EN12390- 8:2019, including surface preparation, priming thesurface with single component high-performancewaterborne tile primer which is suitable for non -porous surface at a rate of 0.14 L/m2 and spreading 45gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwichedbetween the first and second coat completely as perspecification. The finished cost to include surfacepreparation, making coving at Junction, treatment ofcracks completely as per specification.
47Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc
48Oilbound Distember two coats over priming coat with white cement.
49Replacement of Ceiling Plastering with two Coat Putty for PUE School Building at Poolangudi in Palanagudi Panchayat
50Chipping of concrete and roughening the surface
51Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHAcertified Waterproofing coating with flutyne protectiontechnology, single component, cold applied, waterbased acrylic and UV resistant water proofingtreatment to the Existing Roof having Tile or anynon-porous surface applied @ 1.5 l/m2 in 2 coats toachieve 1mm DFT, having tensile strength with 45gsm glass fibre mesh 4N/mm2 confirming to ASTM D412; Elongation at break ≥ 300% and Crack bridgingability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability @5 bar – Nil as per EN12390- 8:2019, including surface preparation, priming thesurface with single component high-performancewaterborne tile primer which is suitable for non -porous surface at a rate of 0.14 L/m2 and spreading 45gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwichedbetween the first and second coat completely as perspecification. The finished cost to include surfacepreparation, making coving at Junction, treatment ofcracks completely as per specification.
52Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc
53Oilbound Distember two coats over priming coat with white cement.
54Replacement of Ceiling Plastering with two Coat Putty for PUE School Building at Chinna Sooriyur (Entrance building) in Sooriyur Panchayat.
55Chipping of concrete and roughening the surface
56Old Terrace tile surface repair with UV Resistant hybrid waterproofing coating Applying Polyurethane hybrid liquid applied GRIHAcertified Waterproofing coating with flutyne protectiontechnology, single component, cold applied, waterbased acrylic and UV resistant water proofingtreatment to the Existing Roof having Tile or anynon-porous surface applied @ 1.5 l/m2 in 2 coats toachieve 1mm DFT, having tensile strength with 45gsm glass fibre mesh 4N/mm2 confirming to ASTM D412; Elongation at break ≥ 300% and Crack bridgingability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability @5 bar – Nil as per EN12390- 8:2019, including surface preparation, priming thesurface with single component high-performancewaterborne tile primer which is suitable for non -porous surface at a rate of 0.14 L/m2 and spreading 45gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwichedbetween the first and second coat completely as perspecification. The finished cost to include surfacepreparation, making coving at Junction, treatment ofcracks completely as per specification.
57Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc
58Oilbound Distember two coats over priming coat with white cement.
59GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \\"BB\\" for all works in this package} Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 54431281
AUTHORITY Local Bodies
TENDER VALUE 14.28 Lakhs
LAST DATE 06-03-2026
Authority
Authority Name Rural Development And Panchayats Department
Work Description Tender For Replacement Of Ceiling Plastering With Two Coat Putty For 9 Schools In Thiruverumbur
Basic Detail
Tender No A2/2692/2026/Nine schools
Bidding Type Tender
Location
City Thiruverumbur
State Tamil Nadu
Key Dates
Publish Date 05 Mar 2026
Submission Date 06 Mar 2026
Open Date 06 Mar 2026
Finance
Tender Value 14.28 Lakhs
Tender Fee Ref. Documents
EMD 14500
Exemption Not Available
Document List
5e71308c-fa15-4fa5-9f95-a2c3d4a3911c.html
BOQ_806038.xls
pricebid.pdf
techbid5.pdf
Tendernotice_1 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

5e71308c-fa15-4fa5-9f95-a2c3d4a3911c.html

xls

BOQ_806038.xls

pdf

pricebid.pdf

pdf

techbid5.pdf

pdf

Tendernotice_1 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders