| 1 | Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone) including removing, spreading and stacking of soils within a lead of 75m.as directed. The item includes trimming the sides of trenches, leveling, and dressing and ramming the bottom, bailing out water etc. as required, complete.Depth of excavation not exceeding 1500mm. For Pump house |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) For Pump house (a) with earth obtained from exavation foundation 1/5 . |
| 3 | Earth work in filling with carried earth arraged by the contractors with in a radius of 3km including cost of carried earth. |
| 4 | Single brick flat soling of Picked Jhama Bricks including ramming and dressing the bed to Proper level and filling joints with powderes earth or local sand. For Pump house |
| 5 | Cement Concrete with 30mm down graded Shingles excluding shuttering (1:3:6) in foundation : For Pump House. |
| 6 | Ordinary cement concrete ( mix 1:1.5:3) with graded stone chips (20mm down excluding shuttering and reinforcement,if any in ground floor. As per relevent I.S. Codes. B) River Bazree |
| 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction.(b) Extra for works beyound the roof of ground floor/ initial 4.0m .(i) Upto 4th floor roof in each addl. Floor (1st floor)a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelI. SAIL/ TATA/RINL |
| 8 | Hire and labour charge for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, columns, lintels curved or staight including fitting fixing and striking out after complection of works. ) upto plinth(a)25 mm. to 30 mm. thick wooden shuttering as per decission & direction of E-I-C. |
| 9 | Brick work in cement morter (1:6) foundation and plinth |
| 10 | 125 mm thick brick work (1:4) with 1st. Class bricks. |
| 11 | Galvanised corrugated iron sheet work fitted and fixed with 10 mm dia J or L hook bolts limpet and bitumen washera) In Roofi) With 0.60mm thick sheet |
| 12 | Galvanised Iron sheet ridging fitted with necessary bolts, screw etc. b) 450 mm laping each way. i) With 0.6 mm sheet |
| 13 | Asbestos corrugated (Trafford or similar approved quality)sheet (6 mm thick) work (excluding the supporting framework) fitted and fixed with 9.5mm. dia. J or L hook-bolt and nuts, limpet and bitumen washers and putty with 150 mm end lap & one corrugation minimum side lap complete. (Payment should be made on area of finished work) |
| 14 | Asbestos ridging (with standard lap) fitted and fixed with necessary hook, bolts, nuts, washers, etc. complete. |
| 15 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to oneanother with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection allcomplete.The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. |
| 16 | Neat Cement Punning about 1.5 mm thick in wall, dado, stair case, sill level etc. |
| 17 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to oneanother with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection allcomplete.The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. |
| 18 | Plaster with sand & cement mortar including rounding off corners etc…(i) with (6:1) cement mortar 15 mm thick. |
| 19 | Applying decorative cement based paint of approved quality……etc. |
| 20 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.Area of each slab / tile not exceeding 0.3 sq.m. |
| 21 | M.S. or W.I. ornamental grill of approved design joints continuously welded with M.S., W.I. flats and bars for windows ,railing etc. fitted and fixed with necessary screws and lugs. Grill weighing above 16kg/sq.m. |
| 22 | Priming one coat on steel or other metal surface with synthetic oil bound prinmer of approved quality including smoothening surfaces by sand papering etc. |
| 23 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)(a)steel or other metal surface |
| 24 | Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material.[Border concrete if necessary to be paid separately].Note: Sub-grade CBR should not be less than 5.iv) For Construction of Sub Base by compacting river bed materials(b) 50 mm thick interlocking designer concrete paver block M- 30 grade for non-traffic zone,buiding premises, garden, parks, domestic drive as per IS: 15658- 2006 (over 20-30 mm medium sand bed on 200mm thk bound gnaular /granular base course including cost of sand for sand bed but excluding cost of base course & subgrade preparation.) |
| 25 | Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750 x 37 mm. thick made with RCC 1:1½:3 with pakur variety stone chips reinforced with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts & bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750 mm. is of section 100 x 13 mm. and 1.90 metre above GL & 0.75 metre below GL including digging hole, repacking the same with cement concrete 1:3:6 with jhama khoa or with local stone chips etc. complete including painting two coats on both faces lettering sign marks etc. as per direction of the Engineer-in- Charge. (The rate is inclusive of cost of reinforcement, concrete, shuttering, nuts & bolts, washer etc. complete.) |
| 26 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(a) For depth upto 150 metre(ii) . 50 mm diaboring |
| 27 | Supplying, fitting and fixing popular Maya pump no-6 or similar.(i) For 40 mm dia. tube well |
| 28 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(A) PVC Pipes 40 mm |
| 29 | Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications.(i) 40 mm dia. |
| 30 | Supplying fitting and fixing GI pipe TATA make with all necessary accessories viz. socket, bend tee union cross elboo nipple etc. |
| 31 | Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets.(i) 40 mm dia. |
| 32 | Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone) including removing, spreading and stacking of soils within a lead of 75m.as directed. The item includes trimming the sides of trenches, leveling, and dressing and ramming the bottom, bailing out water etc. as required, complete.Depth of excavation not exceeding 1500mm. For Pump house |
| 33 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand |
| 34 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes |
| 35 | Plaster with sand & cement mortar including rounding off corners etc…(i) with (6:1) cement mortar 15 mm thick. |
| 36 | Neat Cement Punning about 1.5 mm thick in wall, dado, stair case, sill level etc. |
| 37 | Supply of UPVC B Type & fittings conformin to IS-13592-1992 . A. Single Socketed 3 m length Pipe |
| 38 | 110 mm dia UPVC Nahani Trap |
| 39 | 110 mm dia Plain UPVC Tee |
| 40 | Labour for fitting of 110 mm dia UPVC Pipe |
| 41 | Digging earth in any soil including mixed soil but excluding moorum, laterite sand stone or any other hard stone includingspreading or stacking the spoils within a lead of 75 metres asdirected bailing out water upto 1 metre depth, shoring etc.,when and if required and back filling with fine sand (includingcost of sand) on completion of steining works.A) R.C.C. Ring Welli) 1.2 metre diameter of digging for 0.9 metre internal diameterof well ring.a) Upto 3 metre below G.L. |
| 42 | R.C.C. well ring made with cement concrete 1:1.5:3 with stone chips and 0.80% reinforcement (including the cost of shuttering and reinforcement) cast at site fitted and fixed in position after proper curing true to plumb in the well including jointing with cement mortar 1:2 complete as per direction.a) 65 mm thick and 0.9 metre internal dia. |
| 43 | Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750 x 37 mm. thick made with RCC 1:1½:3 with pakur variety stone chips reinforced with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts & bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750 mm. is of section 100 x 13 mm. and 1.90 metre above GL & 0.75 metre below GL including digging hole, repacking the same with cement concrete 1:3:6 with jhama khoa or with local stone chips etc. complete including painting two coats on both faces lettering sign marks etc. as per direction of the Engineer-in- Charge. (The rate is inclusive of cost of reinforcement, concrete, shuttering, nuts & bolts, washer etc. complete.) |
| 44 | Add for GST @18.00% |
| 45 | Add for L.CESS @1.00% Please Enable Macros to View BoQ information |