| 1 | Swaged steel tubular pole ( 410SP-2) of height 7 Mtr. onfirming to IS:2713 (Part II ) in three section with steel base size, bottom of the pole made of 50 mm dia MSB Clamp pipe welded to 300 mm long MS canopy of suitable dia at an angle of 102.5 suitable size of nuts and bolts including rating of one cost steel primer and two coat of read - oxide all complete as required. (Without Arm) |
| 2 | Single arm |
| 3 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size foundation including excavation and reffiling etc. as reqd. |
| 4 | a) Above 6.5 meter and up to 8.0 mtr. |
| 5 | S.I.T.C of floowing rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required |
| 6 | a) 90w L.E.D. Campus light. |
| 7 | S/F 120W LED Flood light ( on 7 nos Watch Tower) |
| 8 | S/F 100W LED Flood light ( on different Building) |
| 9 | supplying and drawing following sizes of FR PVC insulated copper conductor , single core cable in the existing surface /recessed Steel / PVC conduit as reqd. |
| 10 | a) 3x1.5 sq mm ( for street light ) |
| 11 | a) 3x1.5 sq mm ( for LED flood light on watch tower and different building ) ) |
| 12 | Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as required. |
| 13 | a) 32 Amps, DP Main Switch |
| 14 | S/F 32 Amp flush DP With Neon |
| 15 | Supplying and laying of XLPE insulated PVC sheathed aluminium armoured cable working voltage upto 1100 volts as per IS: 7098 (Part I) of following sizes. |
| 16 | a) 2 core 10 sq mm (For street light on pole) |
| 17 | B) 2 core 6 sq mm (For campus light on Building) |
| 18 | c) 2 core 6 sq mm (For watch tower light from Nearest Street light pole) |
| 19 | d) 4 core 16 sq mm (Pole to Panel) |
| 20 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation, and refilling the tranch etc as reqd. But excluding sand cushioning and protective covering. |
| 21 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 22 | 6/10 sq mm aluminium lugs |
| 23 | 16 sq mm aluminium lugs |
| 24 | Supplying and fixing Cable junction Box without MCB (Make - Sintex/Hensel or equivelant. |
| 25 | S/F 6 to 32 Amps rating , 240 volts , \\"B\\" series , miniature circuit breaker suitable for lighting and other loads of following pole in the existing MCB DB complete with connections , testing and commissioning etc, as reqd . |
| 26 | Earthing with G.I. earth pipe 4.5 mtr long . 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. |
| 27 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required. |
| 28 | Fabrication,installation with 16swg MS sheet with one coat steel primer and two coat spray painting with approved shade making PCC plinth and foundation including fitting fixturing connection transpotation upto work site, labour charge etc all complete as reqd.(for Building Light) |
| 29 | 100 amps, MCCB 10 KA fixed thermal setting - 1 Nos |
| 30 | 32 amp D.P. MCB - 3 Nos |
| 31 | 63 amp D.P. MCB - 3 Nos |
| 32 | LED Indecator lam R/Y/B/G - 3 Nos |
| 33 | 25mm x 5mm copper Strips (2.30 kg/ mtr) |
| 34 | CGST @ 9% |
| 35 | SGST @ 9% |
| 36 | Labour Cess @ 1% Please Enable Macros to View BoQ information |