| 1 | Swaged steel tubular pole ( 410SP-2) of height 7 Mtr. onfirming to IS:2713 (Part II ) in three section with steel base size, bottom of the pole made of 50 mm dia MSB Clamp pipe welded to 300 mm long MS canopy of suitable dia at an angle of 102.5 suitable size of nuts and bolts including rating of one cost steel primer and two coat of read - oxide all complete as required. (Without Arm) |
| 2 | Double Arm (1x2) mtr long |
| 3 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 4 | a) Above 6.5 mtr and Upto 8.0 mtr |
| 5 | S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all neccssary accessories as required |
| 6 | 100 W LED Flood light |
| 7 | S.I.T.C of floowing rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required |
| 8 | 90/100W LED Street light |
| 9 | Supplying and laying of XLPE insulated PVC sheathed aluminium armorued cable working voltage upto 1100 votls as per IS:7098 (prt I) of following sizses. |
| 10 | 10 sq mm 2 core |
| 11 | 3 x 1.5 sq mm |
| 12 | 10 sq mm aluminium lugs |
| 13 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm directr in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering. |
| 14 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 95 sq mm but not exceeding 185 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 15 | Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board . making connections. etc. as required. |
| 16 | 63 Amp TP&N |
| 17 | Providing and fixing following capacity busbar chamber with 4 strips of length 300 mm made of copper suitalbe for following capacity complete with all accessories including connections, earthing the body etc as required. |
| 18 | 100 Amps |
| 19 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 20 | 6 Way Double door |
| 21 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 22 | 40 Amps |
| 23 | Cable junction box with MCB |
| 24 | 80mm dia Earthing Electrode 2mtr. Length / 80mm dia Earthing Electrode 3mtr. Length / 50mm dia Earthing Electrode 2mtr. Length/50mm dia Earthing Electrode 3mtr. Length & Backfill Compound chemical 4 Bag(per bag 25 KG) |
| 25 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required. |
| 26 | SGST @ 9% |
| 27 | CGST @ 9% |
| 28 | Labour Cess @ 1% Please Enable Macros to View BoQ information |