Public Administrative Department Local Bodies Closing in 0 days TDR #54429454

Tender For Provision Of Ac, Cctv, Online Ups Water Cooler & Alllied Works At Puhc Alipur Upgraded As Aam In Ward No. 4 Alipur Under Narela Zone.

Issued by Local Bodies · Narela, Delhi
Tender Value
11.03 Lakhs
Estimated cost
Bid Submission
12 Mar 2026
0 days left
EMD
22100
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Narela → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Provision Of Ac, Cctv, Online Ups Water Cooler & Alllied Works At Puhc Alipur Upgraded As Aam In Ward No. 4 Alipur Under Narela Zone.

BOQ

Name of Work:- Provision of AC, CCTV, Online UPS Water cooler & Alllied works at PUHC Alipur upgraded as AAM in Ward no. 4 Alipur under Narela Zone.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(a)2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(b)3X 4 sq. mm + 1 X 4 sq. mm earth wire
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.3 x 6 sq. mm
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface / recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connections etc. as required.
6Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25MM
7Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole
8Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double Pole
9Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a)8 way Double Door
10Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(a) 125 A, 16KA,TPMCCB
11Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt ) as required.
12Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
13Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
14Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
15Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq.mm ( Clamped with 1 mm thick saddle )
16Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
17Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
18Providing and laying in position cement concrete 1:3:6 (1cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
19Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate up to 50 0C (out door ambient temperature).(a)1.5 TR with fixed speed 5 Star BEE rating (Non inverter type)
20Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). (a) 1.5 TR with 5 Star BEE Rating (Inverter Type)
21Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
22S/I/T/C of stand for split AC
23S/I/T/C of copper pipe for split AC
24S/I/T/C of drain pipe
25S/I/T/C of 3 core, 4 Sqmm. Electrical wire for Air conditioner.
26Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 2*1.0 sq mm
27Supplying and Installation of Reverse Osmosis (RO) water purifier of capacity 50 ltr/hr complete as required.
28Supplying and fixing of full stainless steel body self-contained drinking water cooler with cooling capacity 150ltr per hr, storage capacity 150ltr and suitable for 230V supply as required.
29LED Batten light (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin-Charge as per requirement. (Thermalmanagement: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20 mm) (a)18-22 watt
30Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req (a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
31LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt(a) 100 watt
32P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
33Suuply of following size of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/210 etc as required.3x2.5 sqmm with voltage grade 1100 volts
34Providing and laying i/c HDPE pipe of 40 mm outer dia with PN 4 rating by hand moling / mannual method confirming to IS 4984.
35Supply of XLPE insulated and PVC sheathed Al. conductor armoured cable 1.1 KV grade confirming to IS 7098 as required. (a) 2 x 6 sq mm
36Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. (A) 2KVA
37Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required (c) three run of cable
38Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required (B) two run of cable
39Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(a) One Run of Cable
40SITC of 4MP fixed lens Dome IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 s Frame Rate: 1-20 fps or better ** Lens: 2.8mm fixed Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (2650x1440) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE, DDNS, IEEE802.1X IR Range: Minimum 25mOperating Temperature: -30 to 50 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL
41SITC of 4MP fixed lens Bullet IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better** S/N ratio: >45 dB Lens: 2.8mm fixed Video Compression: H.265 or better** Resolution: (2650x1440) or better** Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 30m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard: IP66 or better** Safety standard: UL \\"
42SITC of 8 channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better**Network Throughput :80 Mbps or better** USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 1 SATA port suitable for 6TB each Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL
43SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100/1000) port slot long distance switch
44SITC of full HD LED Monitor,32 INCHES complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 300 NITS min. Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz at site with connections and along with all accessories etc. Complete as required."
45ITC of full HD LED Monitor,42 INCHES complying with the following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 300 NITS min.Contrast : 1200 : 1 or betterPower supply : 230v + / - 10%, 50 Hz at site with connections and along with all accessories etc. complete as required.
46SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.8 U
47SITC of 6 TB surveillance HDD
48SITC of three phase monoblock pump set complete with all accessorie workable on 415 volts ,50Hz ac supply (a)2 HP three phase monoblock pump set,head from 18-27 metre discharge from 120 to 200 LPM and delivery 50X40 mm.
49Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd.(C) 3 H.P.
50SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switchgears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N)
51Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when gravel stop sinking discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd.
52Comprehnsive Annual Maintenance contract of existing camera as inclusive all of above (CCTV cameras, NVR, complete with all accessories ) all after one year ofdefect liabilty period i/c replaacement of damaged item/part/system with all accessories, spare parts, software, handware etc as required. 2nd year
53Comprehnsive Annual Maintenance contract of existing camera as inclusive all of above (CCTV cameras, NVR, complete with all accessories ) all after one year of defect liabilty period i/c replaacement of damaged item/part/system with all accessories, spare parts, software, handware etc as required. 3rd year
54Comprehnsive Annual Maintenance contract of existing camera as inclusive all of above (CCTV cameras, NVR, complete with all accessories ) all after one year of defect liabilty period i/c replaacement of damaged item/part/system with all accessories, spare parts, software, handware etc as required. 4th year
55Supply,Installation, Testing & Commissioning of portable type CO2 fire extinguisher of 4.5 Kgs capacity completely charged complete with release valve, discharge horn/pipe locking arrangement, wall mounted bracket with screw and sleeve confirming to relevant IS.
56P&F 4 kg capacity Dry powder ABC type (stored pressure) completely charged fire extinguisher complete with pressure gauge, release valve, discharge horn/pipe locking arrangement, wall mounted bracket with screw and sleeve confirming to relevant IS. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 54429454
AUTHORITY Local Bodies
TENDER VALUE 11.03 Lakhs
LAST DATE 12-03-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender For Provision Of Ac, Cctv, Online Ups Water Cooler & Alllied Works At Puhc Alipur Upgraded As Aam In Ward No. 4 Alipur Under Narela Zone.
Basic Detail
Tender No EE/Elect/NZ/2025-26/TC/50.1
Bidding Type Tender
Location
City Narela
State Delhi
Key Dates
Publish Date 05 Mar 2026
Submission Date 12 Mar 2026
Open Date 12 Mar 2026
Finance
Tender Value 11.03 Lakhs
Tender Fee 590
EMD 22100
Exemption Not Available
Document List
a3299881-d074-47c7-b8c3-0042a0c80e77.html
BOQ_314090.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

a3299881-d074-47c7-b8c3-0042a0c80e77.html

xls

BOQ_314090.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders