| 1 | OVERLOAD RELAY 12A TO 18A | OLR WITH 1NO and 1NC CONTACTS THERMAL OVERLOAD CLASS-10A RATED INSULATION VOLTAGE-690V CONFORMING TO IEC 60947-4-1 RELAY SETTING RANGE-12A TO 18A MAKE AND MODEL-LRD21 OF SCHNEIDER ELECTRIC OR EQUIVALENT OF LandT_BCH_SIEMENS |
| 2 | OVERLOAD RELAY 4-5A TO 7-5A | OLR WITH 2NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A RATED INSULATION VOLTAGE-690V CONFORMING TO IEC 60947-4-1 RELAY SETTING RANGE-4-5A TO 7-5A MAKE AND MODEL-MN2 OF LandT OR EQUIVALENT OF SCHNEIDER ELECTRIC_BCH_SIEMENS_CATALOG NUMBER-SS94141OOUO |
| 3 | OVERLOAD RELAY 21A TO 26A | OLR WITH 1NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A_RATED INSULATION VOLTAGE-690V_RELAY SETTING RANGE-21A TO 26A_MAKE AND MODEL-GERT1U OF GENERAL ELECTRIC OR EQUIVALENT OF LandT_BCH_SIEMENS |
| 4 | OVERLOAD RELAY 60A TO 100A | OLR WITH 2NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A_RATED INSULATION VOLTAGE-690V_RELAY SETTING RANGE-60A TO 100A_MAKE AND MODEL-MN12 OF LandT OR EQUIVALENT OF SCHNEIDER ELECTRIC_BCH_SIEMENS_CATALOG NUMBER-SS9438OOKO |
| 5 | OVERLOAD RELAY 18A TO 25A | OLR WITH 1NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A_RATED INSULATION VOLTAGE-690V_RELAY SETTING RANGE-18A TO 25A_MAKE AND MODEL-RTX100 OF LEGRAND OR EQUIVALENT OF LandT_BCH_SIEMENS |
| 6 | OVERLOAD RELAY 30A TO 40A | OLR WITH 1NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A_RATED INSULATION VOLTAGE-690V CONFORMING TO IEC 60947-4-1_RELAY SETTING RANGE-30A TO 40A_MAKE AND MODEL-LRD340 OF SCHNEIDER ELECTRIC OR EQUIVALENT OF LandT_BCH_SIEMENS |
| 7 | OVERLOAD RELAY 40A TO 63A | OLR WITH 1NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-30A_RATED INSULATION VOLTAGE-690V_RELAY SETTING RANGE-40A TO 63A_MAKE AND MODEL-3UC58305G OF SIEMENS OR EQUIVALENT OF LandT_BCH_SCHNEIDER ELECTRIC |
| 8 | OVERLOAD RELAY_ 6-10A | OLR WITH 2NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A_RATED INSULATION VOLTAGE-690V CONFORMING TO IEC 60947-4-1_RELAY SETTING RANGE-6A TO 1OA_AKE AND MODEL-MN2 OF LandT OR EQUIVALENT OF SHNEIDER ELECTRIC_BCH_SIEMENS_CATALOG NUMBER-SS94142OOVO |
| 9 | OVERLOAD RELAY 84-6A TO 135A | CURRENT TRANFORMER OPERATED RELAY-INDIVIDUAL MOUNTING_RELAY SETTING RANGE 84-6A TO 135A_MAKE AND MODEL-BCH OR EQUIVALENT OF LandT_SCHNEIDER ELECTRIC_SIEMENS_CATALOG NUMBER-CT4MC305ANA3C |
| 10 | OVERLOAD RELAY 45A TO 75A | OLR WITH 2NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A_RATED INSULATION VOLTAGE-690V CONFORMING TO IEC 60947-4-1_RELAY SETTING RANGE-45A TO 75A_MAKE AND MODEL-MN5 OF LandT OR EQUIVALENT OF SCHNEIDER ELECTRIC_BCH_SIEMENS_CATALOG NUMBER-SS94137OOJO |
| 11 | OVERLOAD RELAY 54A TO 75A | OLR WITH 1NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A_RATED INSULATION VOLTAGE-690V_RELAY SETTING RANGE-54A TO 75A_MAKE AND MODEL-RTX100 OF LEGRAND OR EQUIVALENT OF LandT_BCH_SIEMENS |
| 12 | OVERLOAD RELAY 30A TO 50A | OLR WITH 2NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A_RATED INSULATION VOLTAGE-690V CONFORMING TO IEC 60947-4-1_RELAY SETTING RANGE-30A TO 50A_MAKE AND MODEL-MN5 OF LandT OR EQUIVALENT OF SCHNEIDER ELECTRIC_BCH_SIEMENS_CATALOG NUMBER-SS94136OOGO |
| 13 | OVERLOAD RELAY 1A TO 1-6A | OLR WITH 1NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A_RATED INSULATION VOLTAGE-690V CONFORMING TO IEC 60947-4-1_RELAY SETTING RANGE-1A TO 1-6A_MAKE AND MODEL-LRD06 OF SCHNEIDER ELECTRIC OR EQUIVALENT OF LandT_BCH_SIEMENS |
| 14 | OVERLOAD RELAY 36A TO 45A | OLR WITH 1NO and 1NC CONTACTS_THERMAL OVERLOAD CLASS-10A_RATED INSULATION VOLTAGE-690V_RELAY SETTING RANGE-36A TO 45A_MAKE AND MODEL-3UA55008M OF SIEMENS OR EQUIVALENT OF LandT_BCH_SCHNEIDER ELECTRIC |