| 1 | Ductable split packaged AC unit: Supply, installation , testing and commissioning of air cooled micro processor controlled ceiling suspended ductable split packaged air conditioners of 8.5 TR nominal capacity, 5780 cmh ( 3400 cfm), 25 mm WC static pressure, equipped with scroll hermetically sealed compressor of 8.5 TR single circuit operating on R410A refrigerant, cross hatched copper tube lanced blue fin condenser, evaporator, thermostatic expansion valve, filter, temperature control, etc., all complete as per the scope of work/technical specification. |
| 2 | Supply and installation of set of seamless annealed hard drawn copper pipes (7/8\\" & 1 1/8\\" ), (18G) 1.2 mm wall thickness and fittings like, bends, couplings, thermal insulation,etc, shall be interconnect between indoor and outdoor unit for suction and discharge connections conforming to ASTM B-68 -02 standards etc., all complete as per specification and as directed by Engineer -in- Charge. |
| 3 | Supply and laying of following size of 1100 V grade, PVC insulated armoured and flexible copper conductor cable shall confirm to IS1554(part -1) and IS 694. It includes glanding and termination of the armoured cables and supply and laying of 8 SWG copper conductor earthing for indoor unit of packaged Air conditioners etc, complete as per specification and as directed by Engineer - In- charge. |
| 4 | Main incoming cable size: 4 core X 10 Sq.mm armoured copper conductor cable |
| 5 | Indoor - outdoor cable size: 6 core X 1.5 sq.mm, 1100V grade, PVC insulated, armoured copper conductor cable.. |
| 6 | 8 SWG copper earth wire double run between Indoor and outdoor units. |
| 7 | Supply, installation , balancing and commissioning of factory fabricated Class VIII , 20G lead free galvanized sheet steel oval ducting with powder coatings(thickness of sheet 1.01 mm)complete with neoprene rubber gaskets, elblows, hangers, supports, etc,. The entire oval ducting work shall be fabricated out of lock-forming grade galvanised sheet steel with specified Zinc coating of grade 375 conforming to IS 277 with powder coatings as per IS 13871. The plenum and ducting shall be complete with necessary Gripple/Clutcher Wire Rope Hanger System. The Ductmate Clutcher/Gripple make stainless steel Hangers are used to suspend oval GSS ducting including providing of vanes, M.S angle support, angle flanges, grill collar, tees, bends etc., All the flanges shall be provided with 6 mm thick felt neoprene gasket at joints , complete as per specification and as directed by Engineer in charge. |
| 8 | Supply and installation of thermal insulation of above ducting with 9mm thick,closed cell Nitrile foam rubber/ cross linked polyehylene thermal insualtion. The insualtion shall be coverd with aluminium foil of 40G thick and fixed properly by self adhesive aluminium tape as per the scope of work. |
| 9 | Supply and installation of 19 mm thick Fibre free and antimicrobial resistant, open cell elastomeric nitrile rubber acoustic insulation in supply air ducts with fire retarred \\"O\\" class, fire performance, resistant to chemical & micro organisum and sound absorption class -D as per the technical specification and scope of work. |
| 10 | Supply and fixing of G.I fire smoke dampers in supply air duct/ main branch and return air passage in the DX -DPAC unit . Fire dampers shall be multi blade louvers type. The blades and frame shall be constructed with minimum 1.6 mm thick G.I sheet . It shall be supplied with spring loaded UL stamped fusible link to close fire damper in the event of rise in air temperature . Fire dampers shall be CBRI tested & certified for required rating adainst collapse & frame penetration complete with locking device. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal etc., complete as per specification and as directed by Engineer in Charge. |
| 11 | Supply and fixing of double deflection type Supply Air Grille/Diffuser of following specification. Extruded anodized aluminium, powder coated, Off white colour, adjustable and locking type aliminium volume control damper having horizontal and vertical louvers. The louver portion shall be removable type for adjusting the Volume Control Damper etc.,all complete per specification and as directed by Engineer - in- Charge. |
| 12 | Supply and laying of 25 mm size CPVC pipe ( SDR 11) conforming to IS :15778 including fixing with required specials, fittings including fixing of G.I \\"C\\" clamp with interval of 1.0 m with sloping, bends , couplings and T - connection etc, all complete as per specification and as directed by Engineer - in- Charge. |
| 13 | Supply and fixing of 40 A rating , four pole, 415 V MCB isolator, 'C' series, Conforms to : IS 13947-3 with powder coated Metal control box for DX -DPAC, complete with connections, testing and commissioning etc., all complete as per specification and as directed by Engineer in charge. Government of IndiaDepartment of Atomic EnergyGeneral Services OrganizationCentralised Tender Cell TENDER DOCUMENT FOR Providing airconditioning system in Multipurpose hall at CISF barracks, Kalpakkam Township. Tender No: GSO/CTC/MSD/298/2026. Part – II : Financial Bid (Section - VIII) INDEX S/No. Title No of Pages |
| 14 | GENERAL INFORMATION FOR GUIDANCE OF TENDERERS |
| 15 | The schedule of quantities is to be read for the purpose of pricing in conjunction with the special conditions, general rules for the guidance of contractors, conditions of contract, specifications, drawings, schedule of supply of materials and the appendices. |
| 16 | The prices inserted in the schedule of quantities shall be inclusive of value of the work described including all cost and expenses, which may be required in and for the construction of the work described together with the general risks, liabilities and obligations not forth or implied in the documents on which the tender is to be based. |
| 17 | The quantities stated are to be considered approximate only and the unit prices entered in the schedule of quantities and prices shall apply only to the actual quantities measured in the completed work in accordance with the specifications. |
| 18 | All the materials other than those shown in schedule of supply of materials in section VII are to be arranged by the contractor and his rates should account for the same. |
| 19 | Rates quoted for all items in this tender shall include cost of all materials. Department will not supply any materials other than materials stipulated in Section - VII of the tender and as such the rates quoted must be all inclusive. |
| 20 | If contractors need any clarification they are required to contact the ‘Engineer-In-Charge, CTC, ESG, GSO, Kalpakkam – 603 102, Chengalpattu district, Tamilnadu (Ph – 044-27480500 Extn. 85803, 85352) during office hours. Please Enable Macros to View BoQ information |