| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical MeansItem / Page No : 2 / 153Specification No : Bd.A.1Spec. Page No : 259 |
| 2 | Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical MeansItem / Page No : 6 / 153Specification No : Bd.A.2Spec. Page No : 259 |
| 3 | Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, excetra complete.Item / Page No : 38 / 157Specification No : Bd.A.12Spec. Page No : 264 |
| 4 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).Item / Page No : 1 / 175Specification No : Bd.E.1Spec. Page No : 287-288Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 5 | Providing selected hard murum filling including laying in layers of 15 centimetre to 20 centimetre, watering and compacting, excetra compelte.Item / Page No : 24 / 82Specification No : CD.14Spec. Page No : 167 |
| 6 | Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete.Item / Page No : 36 / 157Specification No : Bd.A.10Spec. Page No : 262-263 |
| 7 | Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete.Item / Page No : 37 / 157Specification No : Bd.A.11Spec. Page No : 263-264 |
| 8 | Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).Item / Page No : 11 / 178Specification No : Bd.F.3, B-7Spec. Page No : 298, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 9 | Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 31 / 179Specification No : Bd.F.5, B-7Spec. Page No : 300, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 10 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 50 / 181Specification No : Bd.F.6, B-7Spec. Page No : 300-301, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 11 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 70 / 182Specification No : Bd.F.8, B-7Spec. Page No : 302-303, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 12 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) (For Ground Floor)Item / Page No : 33 / 188Specification No : Bd.F.17Spec. Page No : 306 |
| 13 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 197Specification No : Bd.G.5Spec. Page No : 315Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 14 | Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 7 / 209Specification No : Bd.L.4Spec. Page No : 368Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 15 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 11 / 209Specification No : Bd.L.7Spec. Page No : 369Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 16 | Providing and laying matt finish ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to Indian Standard 15622 : 2006 (Group DII-A) and 7 milimetre to 8 milimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white / colour cement slurry, cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 24 / 215Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 17 | Providing and laying ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to corrosponding Indian standared for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 25 / 215Specification No : Bd.M.13Spec. Page No : 386Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 18 | Providing and fixing heavy duty inter locking concrete coloured paving blocks of 60 milimetre thickness of having a strength of 300 kilogramme per square centimetre of approved quality and shape on a bed of crushed sand of 25 milimetre to 30 milimetre thick including striking joints and cleaning, excetra complete.Item / Page No : 51 / 218Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 19 | Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For Ground Floor)Item / Page No : 9 / 246Specification No : Bd.T.34Spec. Page No : 499 |
| 20 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 68 / 220Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 21 | Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)Item / Page No : 2 / 264Specification No : Bd.U.1Spec. Page No : 537 |
| 22 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For Ground Floor)Item / Page No : 68 / 259Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 23 | Providing and laying in trenches 15 milimetre diameter chlorinated poly vinyl chloride pipe including necessary excavation, fittings, refilling trenches, excetra complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.Item / Page No : 61 / 280Specification No : Bd.V.5Spec. Page No : 551Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 24 | Providing and laying in trenches 20 milimetre diameter chlorinated poly vinyl chloride pipe including necessary excavation, fittings, refilling trenches, excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.Item / Page No : 62 / 281Specification No : Bd.V.5Spec. Page No : 551Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 25 | Providing and laying in trenches 25 milimetre diameter chlorinated poly vinyl chloride pipe including necessary excavation, fittings, refilling trenches, excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.Item / Page No : 63 / 281Specification No : Bd.V.5Spec. Page No : 551Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 26 | Providing and fixing 15 milimetre diameter screw down bib / stop tap of brass including necessary socket union nut complete. (For Ground Floor)Item / Page No : 40 / 270Specification No : Bd.V.8Spec. Page No : 554 |
| 27 | Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. (For Ground Floor)Item / Page No : 45 / 270Specification No : Bd.V.9Spec. Page No : 555 |
| 28 | Providing and fixing 15 milimetre diameter concussion push button type brass / gun metal self-closing tap including necessary socket complete. (For Ground Floor) (For Ground Floor)Item / Page No : 52 / 270Specification No : Bd.V.14Spec. Page No : 557 |
| 29 | Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection, excetra complete. (For Ground Floor)Item / Page No : 34 / 277Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 30 | Providing and fixing 100 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps, excetra complete. (For Ground Floor)Item / Page No : 52 / 279Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 31 | Providing and fixing 10 centimetre cast iron nahani trap including cast iron grating, bend and piece of cast iron pipe upto the outside face of the wall complete. (For Ground Floor)Item / Page No : 80 / 273Specification No : Bd.V.32Spec. Page No : 567 |
| 32 | Providing and fixing hume pipe septic tank 900 milimetre diameter with vent pipe and cap including excavation and laying.Item / Page No : 18 / 275Specification No : Bd.V.45Spec. Page No : 575 |
| 33 | Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housting, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes. Capacity between 200 litres to 1000 litres. (For Ground Floor)Item / Page No : 53 / 280Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 34 | Providing and fixing white glazed earthenware wash hand basin of 63 centimetre X 45 centimetre size including Bib cock stop tap brass heavy 15 milimetre, brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including polyvinyl chloride waste pipe and trap upto the outside face of the wall. (For Ground Floor)Item / Page No : 65 / 272Specification No : Bd.V.30Spec. Page No : 565 |
| 35 | Providing and fixing white glazed earthenware full stall type urinal with poly vinyl chloride flushing cistern of 5 litres capacity with fitting inlet pipes and stop tap brackets for fixing the cistern 32 milimetre diameter poly vinyl chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection upto the outside face of the wall. (For Ground Floor)Item / Page No : 57 / 271Specification No : Bd.V.23Spec. Page No : 562 |
| 36 | Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with polyvinyl chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connection up to the outside face of the wall. (For Ground Floor)Item / Page No : 58 / 271Specification No : Bd.V.23Spec. Page No : 562 |
| 37 | Providing and constructing brick masonry inspection chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels, half round glazed stoneware pipes, brick masonry, plastering from inside and airtight cast iron lid 75 kilogram with frame fixed in cement concrete, excetra complete. (using ARTIFICIAL SAND).Item / Page No : 10 / 274Specification No : Bd.V.43Spec. Page No : 574Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 38 | Providing and fixing 40 milimetre diameter ball cock medium type with polyvinyl chloride float including sockets and necessary fittings and tested as per municipal requirements, excetra complete. (For Ground Floor)Item / Page No : 36 / 277Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 39 | Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.Item / Page No : 4 / 0Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. 2. Above / below percentage quoted by the contractor will not be applicable for this item.Crushing Value / Compressive Strength, Water Absorption, Specific Gravity Test for Stone / Rubble1 Test per |
| 40 | Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.)Item / Page No : 3 / 0Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5. 2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work. 3. Above / below percentage quoted by the contractor will not be applicable for this item. |
| 41 | [Providing and fixing 90 centimetre X 60 centimetre granite name plate engraving 10 centimetre height letter, figures including painting the letters / figures with approved colour and shade complete.Item / Page No : 12 / 294Specification No : Bd.W.7Spec. Page No : 586-587 Please Enable Macros to View BoQ information |