| 1 | 4.16 Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting on OMC using vibratory roller of 80 to 100 kN static weight. Field compaction shall be done in corresponding layers of carriage way thickness and meet the requirements of MDD to achieve compaction (98% -100%) as per relevant clause of 408.A Hard Shoulders (CBR value >12) |
| 2 | 5.3 Providing and applying tack coat with cationic bitumen emulsion using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications.(ii) @0.30 kg per sqm (dry & hungry bituminous surfaces /Granular surfaces treated with primer) |
| 3 | 5.6 Dense Graded Bituminous MacadamProviding and laying dense bituminous macadam using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with an Electronic Sensor paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per clause 505 of specification complete in all respects.b) Using Drum Mix Plant of appropriate capacity(iv) for Grading II (26.5 mm nominal size) Bitumen Content minimum 4.5% with bitumen 60/70 (VG 30) |
| 4 | 5.7 Bituminous ConcreteProviding and laying bituminous concrete using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % by weight of total mix of mix and filler, transporting the hot mix to work site, laying with an Electronic Sensor paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory tandem and pneumatic tyre rollers to achieve the desired compaction as per clause 507 of specification.b) Using Drum Mix Plant of appropriate capacity.(iv) for Grading-II (30-40 mm thickness) Bitumen Content minimum 5.4% with 60/70 bitumen (VG-30) |
| 5 | 8.36 Kilo Metre StoneReinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc(ii) Ordinary Kilometer stone (Precast) |
| 6 | (iii) Hectometer stone (Precast) |
| 7 | (iii) Hectometer stone (Precast) |
| 8 | 8.3 Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT &H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. ............iv) 60 cm equilateral triangle |
| 9 | viii) 60 cm circular |
| 10 | x) 80 cm x 60 cm rectangular |
| 11 | xii) 60 cm x 45 cm rectangular |
| 12 | xiii) 60 cm x 60 cm square |
| 13 | xv) 90 cm high octagon |
| 14 | 8.7 Direction and Place Identification signs more than 0.9 sqm size board.Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT&H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on 2 nos. of MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. |
| 15 | 8.44 Painting Lines, Dashes, Arrows etc on Roads in Two Coats on New WorkPainting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road Grade-I marking paint (cold applied reflective paint) conforming to IS:164 on concrete/bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control.(i) Over 10 cm in width Please Enable Macros to View BoQ information |