| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.-All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil |
| 3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitablemethod complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate20 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level:1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement:-1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five levelexcluding the cost of centring, shuttering, finishing andreinforcement:1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Centering shuttering including struttings, propping etc.and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 9 | Centering shuttering including struttings, propping etc. and removal of form work for: Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank |
| 10 | Centering shuttering including struttings, propping etc. and removal of form work for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank |
| 11 | Centering shuttering including struttings, propping etc. and removal of form work for:-Suspended floors, roofs, landings, balconies and access platform with timber planks |
| 12 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 13 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 14 | First class brick work in foundation and plinth including cost of all materials as required complete: In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 15 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete: In cement mortar 1:5 ( 1 cement : 5 fine sand ). |
| 16 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:- Using flats 30x6mm for diagonal braces and central cross piece. |
| 17 | 6 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 18 | 12 mm cement plaster of mix in Cement mortar:- Cement mortar 1:4 (1 cement : 4 fine sand) |
| 19 | 15mm cement plaster on the rough side of single or half brick wall of mix: In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 20 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 21 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :12.39.1 New work ( two or more coats applied @ 3.84 kg/10 sqm) |
| 22 | Finishing with Epoxy paint ( two or more coats) of approved brand and manufacture at all locations prepared and applied as per manufacturer's specification including appropriate priming coat, preparation of surface etc. complete [Payment shall be made after submission of Test Certificate issued by the Manufacturer]. 12.48.1 On steel work. |
| 23 | Neat Cement Punning |
| 24 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 25 | Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge. 450 mm X 300 mm in all shades and design. |
| 26 | Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory,Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge. 10.41.1 Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles 10.41.1.1 300 mm x 300 mm in all shades and designs. |
| 27 | Providing and fixing chequered terrazo tiles 22 mm thick with graded marble chips of size upto 6 mm, laid on floors, footpath & courtyard on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and polishing complete. Dark shade pigment using ordinary cement |
| 28 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 29 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap. |
| 30 | Making connection of G.I. distribution branch with G.I. main following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete as per CPWD specification and direction of the Engineer - in - charge. 19.13.1 25 to 40 mm nominal bore. |
| 31 | Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I. fittings and clamps, including cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in charge. Internal work - Exposed on wall. 19.10.1 15 mm dia. nominal bore . |
| 32 | Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling etc. complete as per CPWD specification and direction of theEngineer - in - charge. External work.25 mm dia. nominal bore. |
| 33 | Providing and fixing soil, waste and vent pipes: 100 mm dia. Sand cast iron S&S pipe as per IS: 1729. |
| 34 | Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:-G.I.pipes. |
| 35 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Coupler 110 mm |
| 36 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 6 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: Single socketed pipe - 110 mm OD |
| 37 | Providing and fitting fixing of 1500 GPH Capacity submerssible with 10 stage pump with suitable single phase 1HP submerssible motor with head of 48.00 mtr.DUKE make/VARUNA Make/and other ISI mark make etc complete in all respect as per direction of the Engineer-in-charge Please Enable Macros to View BoQ information |