| 1 | Civil Works |
| 2 | Supplying and fixing of bison panel boards (cement board / calcium silicate board) of 10mm thick panel of size 8' x4' as approved by Architect/ Engineer -in charge, fixed over G.I framework of 48mm x 35mm x 0.8mm or 75mmx 35x 0.8mm lip‘C’ studs @ 610mm Vertical x 1200mm Horizontal spacing or equivalent aluminum sections 64x38x 2mm. The gap between the boards shall be filled with 50mm thick poly wool. The tiles are to fixed to Aluminum frame using seam fasteners etc. The surface should be finished with 1mm thick mica of appropriate shade using necessary adhesive, nails etc. complete or interior emulsion paint of two or more coat of approved colour with 1mm thick wall putty etc. complete as directed by Engineer in charge. (deduction towards opening will be made for the measurement) |
| 3 | Providing and applying cement based putty M/s Birla or equivalent of upto 2 mm thickness over plastered surface to prepare the surface even and smooth etc complete |
| 4 | Interior painting: (two or more coats over a primer coat including complete scraping, other surface preparation like removal of loose paint residuals, damaged plastering, repairs to plaster, white cement based (JK / Birla) touch up putty / primer and making good the wall surface etc) Applying interior paint of approved colour, make, brand and product at the approved rate of surface coverage of painting as per Annexure A.1.3. The interior paint shall be applied over dry surface after complete scraping and removal of all loose or defective paint or powdery residue using mechanical methods with Zero dust vacuum technology followed with sealing the surface with a coat of approved interior primer before application of top coat of exterior paint. The contractor shall also carryout necessary surface preparation including removal of loose plastering, patch plastering, crack filling, micro-concreting, application of damp proof coating and making good the wall surface etc wherever required before applying primer coat. The contractor should ensure complete covering of floors using tarpaulin / plastic sheet while taking up the work. The work shall be executed as per the detailed specifications and special conditions mentioned in the Annexure 1. The rate quoted shall be inclusive of charges towards all labour, material, transport, scaffolding, safety arrangements, Personal Protective Equipments (PPE), tools and plants etc. |
| 5 | Painting and finishing with Textured paint with Asian, Suzuka or Ultra tech and manufacture of required colour to give an even shade: Two or more coats including primer on new work over an under coat of suitable shade paint of approved brand and manufacture. Samples to be approved by EPC and architect. |
| 6 | Providing and fixing 12 mm thick framed (Top and bottom) toughened glass partition of approved brand and manufacture, inclusive of providing and fixing framing, making necessary holes etc. for fixing required door fittings, all complete |
| 7 | Providing and Fixing colour anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS :733 and IS 1285, fixed with rawl plugs and scews or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / Stainless steel screws, all complete as per architectural drawings and the directions of Engineer - in- charge. (Glazing and panelling to be paid for separatelly) For fixed portion Anodised aluminium (anodised transport or colour anodized dyed to required shade according to IS 1868, Minimum andioc coating of grade AC 15) |
| 8 | For shutters -Providing and Fixing colour anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS :733 and IS 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastens including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / Stainless steel screws, all complete as per architectural drawings and the directions of Engineer - in- charge. (Glazing and panelling to be paid for separately) For Shutters Anodised aluminium (anodised transport or colour anodized dyed to required shade according to IS 1868, Minimum anodic coating of grade AC 15) |
| 9 | Providing and fixing of glazing to door/ window/ ventilator shutter and partition etc with pvc neoprene gasket / wooden reapers / necessary adhesives etc complete as per the direction of engineer in charge (Saint Gobain / Modi float).5mm thick float glass |
| 10 | Providing and fixing 4 lever mortice lock godrej / link including repair to the door etc., complete |
| 11 | Providing and Fixing Stainless steel butt hinges with stainless steel screws etc., complete as per IS:12817 : 150x65x1.90mm. |
| 12 | Providing and Fixing Aluminum Handles ISI marked anodised (anodic coating not less than Grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc., complete: 150mm. (JAL / CLASSIC / CROWN) |
| 13 | Providing and Fixing Aluminum sliding door bolts ISI marked anodised (anodic coating not less than Grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc., complete: 250x16mm. (JAL / CLASSIC / CROWN) |
| 14 | Providing and fixing IS 3564 marked Aluminum die cast body tubular type universal hydraulic door closer hardwyn make (classic queen) or equivalent with necessary accessories and screws etc complete( including removing charges) |
| 15 | Providing and fixing Dorma make heavy duty Lock ( Model number 278 )for entrance Main door as per the direction of Engineer in charge. |
| 16 | Providing and fixing DORMA patch fitting of PT 20-Top Patch & PT 10-Bottom patch with special accessories for glazed door etc. |
| 17 | Providing and fixing DORMA patch fitting of US 10 Corner lock with EPC & LKP with special accessories for glazed door etc., |
| 18 | Providing and fixing Dorma make (Model number XLC -34H ) 30x 600mm long heavy duty tubular handles for entrance Main door as per the direction of Engineer in charge. |
| 19 | Providing and fixing DORMA floor spring BTS80 (heavy duty) with special accessories for aluminium or glazed door etc., |
| 20 | Providing and fixing DORMA floor spring BTS 75V with special accessories for aluminium or glazed door etc., |
| 21 | Providing & fixing horizontal level suspended ceiling comprising of Knauf Vertical Linear Baffle Ceiling made out of Aluminium Extrusion in Aluminium alloy grade 6063 T5. The baffle blade shall be in size of 100x50x3600mm in powder coated to Woodgrain finish (WEF 07 Color). The baffle shall be electrostatically polyester powder coated to a coating thickness of 60-80 micron. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacturing batch shall be delta E<1 using Excite/BYK Gardner instrument and gloss level 25±5% at 60˚ as per ASTM D523 (Not applicable of Wood Grain Shade). The baffle blade shall be suspended using Slotted U-profile of 20 x 30 x 3700mm (Thk-1.5mm) having slots in module of 25mm to keep baffles at an on-centre spacing in multiples of 25mm. Longer lengths of Baffle to be connected by Baffle Joiner and the ends to be fixed with End caps. The Distance between the 2 baffle centre to centre is 200MM & Clear Spacing of 150MM.SUSPENSION: Shall be hanged using baffle hanger from U-profile made of mild steel with powder coating thickness of 60-80 micron. The U – profile to comprise of alternate square & rectangular slots of 6.5x6.5mm & 28x6.5mm,respectively on the web for locking the baffle hanger using plugin clip to secure the hanger in perfect position and achieve uniform spacing between baffles. The overall dimension of the U – profile is 20(W) x 30(H) x 3750(L) mm and is rolled form from 1.5mm thick mild steel with a powder coating thickness of 60-80micron. U- Profile to be connected to each other using U –Profile Splice. The U- profile shall be hanged from the true ceiling using threaded rod using a U- Profile hanger. |
| 22 | INSTALLATION: Installation of U-Grid:The U profile to be suspended at every 1200mm centre to centre using 6mm threaded rod from the structural soffit using U-profile hanger. U-profile splice to be used to join more than one U profiles of length 3.7M. 1st U-Grid Channel must be no more than 400mm from the perimeter. Installation of Knauf Baffles: Locate the slot for Baffle Hangers in U Profile section at 1200mm centre's. Hangers are inserted into the slot, then rotated 90° and fixed into position by tightening the grub screw. Baffle to be lifted into position and hangers engage over lip of U-Grid Channel. Each Hanger to be secured into position by inserting the Locking Clip. When doing continuous installation, Baffles blades are to be connected at ends with Baffle Joiner, which are inserted into the top and bottom slots of the Baffle closed profile for alignment only. The bottom Joiner to be located first and fastened on one side only. The top Joiner to be fitted then and secured with grub screws on one side. Then the two Baffle sections shall be joined and the top Joiner is screw fastened on the 2nd Baffle profile. End Caps to be located by pushing the End Cap tongues into open Baffle slots. Installation should be carried out as per Knauf recommended procedure.KNAUF CEILING SOLUTIONS METALWORKS LINEAR BAFFLE CEILING(100 X 50mm) WITH U-PROFILE SYSTEM -200 mm C/C and Clear Spacing of 150mm. |
| 23 | Providing and fixing horizontal level Knauf Cellio Open cell GI lay-in ceiling tiles with border panels forming board edge of size 600x600x38mm (Nominal) having cell size of 100x100mm made of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.35mm thickness as per in IS:513 (1994) in Global White Color. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 hours as per ASTM B117, QUV –A Test for 1000 hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000 hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. Tile shall have a Fire Performance class A1 as per EN-13964. SUSPENSION: The tile shall be laid on Knauf Suprafine 32 with 15 mm wide T - section flanges colour matching to tile having double stroke rotary stitching on all T sections i.e., the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm (all sections). The deflection loading of the system shall be 7.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel clip fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull-out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel 90 gsm and pre-painted steel with baked polyester paint of 0T bending capability. |
| 24 | INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using Knauf suspension system (specifications below) at 1200mm maximum. The First/Last Knauf suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Knauf wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. All border cut tiles shall be laid, using Knauf lay-in end cap for installation to have a Microlook effect on perimeters. Installation shall be carried out as per Knauf recommended procedure. KNAUF SUSPENSION SYSTEM accessories manufactured and supplied by Knauf consisting of M6 Anchor Fasteners with hanger hole, pre–Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. Additionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners KNAUF CEILING SOLUTIONS CELLIO OPEN CELL 100MM CELL SIZE LAY-IN GI CEILING WITH KNAUF SUPRAFINE 32 WITH 15MM EXPOSED GRID SYSTEM |
| 25 | Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc including cutting , hoisting, fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc complete Hot finished welded type tubes - 80x40x4 mm (6.97 kg/m) |
| 26 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red |
| 27 | Supply & installation of fascia Salon Sonator Slat made of pinewood E1 grade fibreboard, melamine/veneer laminated finish, FR Grade, size 1220x2440x17mm, square edge, volume density of base board 750Kg/m3, weight 12Kgs/m2 installed by using Anutone Strut framework system and Anutone Strut Z bar. Anutone Strut framework system includes Anutone Strut CC25 having thickness 0.55mm, length 3600mm, knurled web 35, depth 20mm and equal flanges 15mm is fastened to wall positioned vertically in a regular manner at 600mm c/c. Anutone Strut Z bar having 40mm height, thickness 1mm is first fixed behind the panels by using suitable fasteners. Another length of Strut Z bar are then installed over Strut CC25 horizontally at spacing so as to match with Strut Z bar at rear of Sonator. Salon sonator panels of size 1220x2440x17mm are then slided into the Strut Z bar fixed on Strut CC25. Long edges of panels should be perpendicular to Strut Z bar and Short edges of the panel are staggered. • Fire (Class) – 1 & P• Acoustics – NRC upto 0.25• Thermal conductivity (W/mk)– na• Climate (°C, RH) – 40, 70• Light reflectance (%) – Colour Dependant• Green (VOC, RC %) – Low, 25 |
| 28 | Supply and Installation of Anutone Subtex NRC burled square edge, FR grade NRC fabric (colour choice) wrapped glassfibre core panel of size 600x1200x25mm having density 100-120Kgs/m3, weight 3.0kg/m2 installed by using impaling clip. Impaling clips are attached directly to the wall/frame work/plywood backing with the points extending outward. The spikes are tipped with Stick S7 adhesive. Then the panels are positioned and pressed into place. Technical Parameters Core - Glassfibre• Fire – Class 1 & P• Acoustics – NRC up to 0.9• Climate (OC RH) – 40, 90• Termite resistance – Yes• Light reflectance – Colour dependent• Green (RC %) – 25• Hygiene (VoC, Clean room) – Low, Class 3 |
| 29 | SOLO CIRCLE 1200 DIA * 40 MM THICK (WITH ACCESSORY), horizontal element with painted edges and without profiles, having recycled content of minimum 70%, with Akutex FT surface in white frost on all sides and can be weekly wet cleaned and daily dusting or vacuum cleaned. The surface should perform for 99% diffused light reflection. The element withstand a permanent ambient RH up to 95% at 30 degree c without sagging, warping or delaminating (ISO 4611). The glass wool core of the element is tested and classified as non combustible according to pr EN ISO 1182. Should have certified by the indoor climate labelling, recommended by Swedish asthma & allergy association and can be used in rooms classified as ISO 6/M3.5 Brand: Ecophon or equivalent brand and manufacturer. |
| 30 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. Brands: Saint Gobain GYPROC, Anutone Pixel 0308 or Knauf Ceiling (Armstrong) Ultima |
| 31 | Providing & Fixing premium quality Roller blinds with Serge Ferrari Soltis-96 or Hunter Douglas. Prestress Micro-Aerated Solar protection fabric of high tenacity Polyester Yarn with PVC Coating.Roller Tube: Roller Tube shall be of extruded Aluminium alloy 38mm O.D (or as per system dimension) with a minimum wall thickness of 1.0mm duly anodised for long life.Clutch: Clutch shall be wrap spring design with high strength fibreglass reinforced polyester assembly and high carbon steel springs to transmit motion from driving to driven members of clutch mechanism. Idler: Idler shall be of high strength fibreglass reinforced polyester, consisting of an outside sleeve and centre shaft. Installation Brackets: Brackets shall be of atomised steel powder coated to give superior finish. Bracket shall accommodate overhead, side or face mounting with clutch assembly on either end of the roller. Bottom Rail: Bottom of the blind shall be provided with aluminium tube powder coated in a colour matching to the fabric. Fabric: Composition: 40% Polyester / 60% PVC, Weight:400 g/m2 (+/-5%), Thickness:0.45 mm (+/-5%), Fabric Openness Factor: 4% , Tensile Strength (Warp/Weft): 220/220 daN / 5cm, Tearing Strength (Warp/Weft): 30/25 daN, Fire Retardancy:M2 (NFP92-507) |
| 32 | RECEPTION CEILING OPTION 1 - SONATOR STRUT Supply & installation of Anutone Salon Sonator made of pinewood E1 grade fibreboard, melamine/veneer laminated finish, FR Grade, size 1220x2440x17mm, square edge, volume density of base board 750Kg/m3, weight 12Kgs/m2 installed by using Anutone Strut framework system and Anutone Strut Z bar. Anutone Strut framework system includes Anutone Strut CC25 having thickness 0.55mm, length 3600mm, knurled web 35, depth 20mm and equal flanges 15mm is fastened to wall positioned vertically in a regular manner at 600mm c/c. Anutone Strut Z bar having 40mm height, thickness 1mm is first fixed behind the panels by using suitable fasteners. Another length of Strut Z bar are then installed over Strut CC25 horizontally at spacing so as to match with Strut Z bar at rear of Sonator. Salon sonator panels of size 1220x2440x17mm are then slided into the Strut Z bar fixed on Strut CC25. Long edges of panels should be perpendicular to Strut Z bar and Short edges of the panel are staggered. • Fire (Class) – 1 & P• Acoustics – NRC upto 0.25• Thermal conductivity (W/mk)– na• Climate (°C, RH) – 40, 70• Light reflectance (%) – Colour Dependant• Green (VOC, RC %) – Low, 25 |
| 33 | RECEPTION CEILING OPTION 2 - STRETCH CEILING Providing and installing PVC stretch ceiling system for the reception area, suitable for Grade-A office spaces , comprising fire-retardant PVC membrane (minimum 0.18 mm thick) with approved matte/satin/gloss finish, fixed to concealed aluminium / PVC perimeter track system, complete with heat-stretch installation to achieve a smooth, level, wrinkle-free surface. The system shall comply with applicable Indian standards and local fire safety norms (minimum Class B-s1, d0 or equivalent), be moisture-, humidity- and mold-resistant, and suitable for air-conditioned office environments. Provision shall include reinforced cut-outs for lighting fixtures, HVAC diffusers, sprinklers and detectors as required. Rate to include all materials, accessories, fixings, labour, tools, testing, and a minimum 10-year manufacturer warranty, complete in all respects. |
| 34 | Supplying and fixing name board indicating department name made out of Aludecor 3mm Aluminium Composite Panel, with letters should be carved using CNC Router cutting over the ACP panel and carved portion should be sealed with 2mm 040 Imported Acrylic sheet. The rate is inclusive of providing internal lighting |
| 35 | SEMI UNITIZED STRUCTURAL GLAZING FRAME WORK WITH OUT GLASSThe project involves the provision and installation of a semi-unitized structural glazing 3 barrier system utilizing a colour-anodized 15 to 20 MICRON Jindal or equivalent aluminium mainframe with dimensions of 131.00 x 67.00 x 2.00 mm for both vertical and horizontal sections. This system is engineered to withstand wind pressure per relevant codes.The mainframe will be securely attached to the RCC slabs using necessary aluminium or GI angle cleats equipped with slots for plumb adjustments, affixed with M10 expansion anchors or equivalent fasteners. The vertical sections of the mainframe will accommodate an unsupported length of up to 3.5 meters. The glazed panels will feature a sub frame made of 66.00 x 29.00 x 1.50 mm sections, employing double-sided cross-linked polyethylene spacer tape and Dow Sil 795/995 structural sealants. This design ensures that the dead weight of the glass is properly transferred to the mainframe, preventing undue stress on the structural sealant. Following proper curing in an unobstructed environment, the glazed panels will be fixed to the mainframe from the exterior. This allows for future glass replacement as needed. The grooves, measuring 12 to 14 mm, will be sealed with weather-grade Dow Sil 791 silicone sealant. The rate includes the installation of the mainframes into masonry walls or RC concrete surfaces using stainless steel nuts, bolts, rivets, and washers. All necessary clamps, Fischer/Hilti fasteners, and brackets will be made from galvanized steel or aluminium, adhering to industry standards. It is imperative that all hardware used in this system is corrosion-resistant. The overall assembly must be fully weatherproof, accommodating necessary thermal expansion and contraction, while being capable of withstanding specified wind loads.ONLY FRAME COST. |
| 36 | EXTR FOR 8MM THICK SAINT GOBAIN ST 136 + 1.52 PVB CLEAR LAMINATION + 8 MM GLASS OVER THE ABOVE FRAME COST.Saint Gobain 8mm thick ST136 toughened + 1.52 PVB Clear Lamination + 8mm clear toughened glass over and above the frame cost. |
| 37 | EXTRA FOR OPENABLE WINDOW. ONLY HARDWARE.Extra for openable panels in Semi unitised structural glazing with secure style friction staysSTORM B 26 SPT26, SR8 Restrictor, CPB1 pull in blocks, ALUALPHA 670 Handle,S14P23extensor, 9312 and 9313 along with all accessories, complete |
| 38 | Brick work with Fly ash concrete blocks of class designation M100 upto V floor levelsCement mortar 1:4 (1cement :4 coarse sand / M sand) |
| 39 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - Upto V floor level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 40 | PANTRY CABINETS - Providing and fixing box type cupboard (standalone or wall mounting) of 400 mm to 600 (depth of the cupboard) thick with glazed or plywood openable made of 19mm thick BWR plywood (Kitply / Century ply) and laminated with 1mm thick lamination sheet (Greenlam / Sunmica) for all exposed surfaces and using 6mm thick float glass for glazed shutter (Saint Gobain / Modifloat), 12mm BWR plywood for openable shutter with laminate plywood and inner surfaces finished with two coats of enamel paint (Measurement for cupboard Length x Height). Rate inclusive of necessary fixtures for wall mounting, SS fixtures of M/s Ozone make for handle, hinges, tower bolt, magnetic catcher, cabinet / frog hinges of Hafele or Ozone make etc., complete. (PANTRY) |
| 41 | Providing and fixing CP brass Pillar cock & wash basin (counter top or counter bottom) (So many -Oval type 460x342x155mm square type 515x380x120mm making good the walls etc complete. White Vitreous china wash basin 550mm excluding cost of fittings. ((Parry ware / Hind ware/ So many) |
| 42 | Providing and fixing of CPVC pipe with necessary couplings, solution and special clamp as per approved make Supreme / Ashirvad or Equivalent ISI Make etc. complete25 mm dia nominal bore (The rate is inclusive of all necessary tees, bends etc.) |
| 43 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. - 110 mm diameter with other necessary Tees, bend union etc Please Enable Macros to View BoQ information |