| 1 | Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared) |
| 2 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof. |
| 3 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m.In ground floor including roof. (a) upto 150 mm. thick |
| 4 | Dismantling all types of masonry excepting cement concrete plain or reinforced,stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. |
| 5 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 6 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil butexcluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75m. as directed. The item includes necessary trimmingthe sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm. |
| 7 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation. |
| 8 | Filling in foundation or plinth by Fine Sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity) |
| 9 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 10 | 125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in G.Floor. |
| 11 | Brick work with 1st class bricks in cement mortar (6:1) (a) In foundation and plinth |
| 12 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] 1:3:6 proportion |
| 13 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety |
| 14 | Ordinary Cement Concrete( mix.1:1.5:3) with graded stone chips(20 mm.nominal size) excluding shuttering and reinforcement, if any, in ground floor,as per relevant I.S.Codes,Pakur variety. |
| 15 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor). (b) 25 mm. to 30 mm. thick wooden shuttering without staging in foundation. |
| 16 | (a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge. |
| 17 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation, basement, and upto roof of ground floor / upto 4m. (i) Tor steel/Mild Steel . I. SAIL/TATA/RINL |
| 18 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 19 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within alead of 75m as directed. |
| 20 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (a) With 6:1 cement mortar 15 mm. thick plaster |
| 21 | 20 mm. thick plaster |
| 22 | (ii) With 4:1 cement mortar (a) 10 mm. thick plaster |
| 23 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. |
| 24 | Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. |
| 25 | (b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand (1.5mm thick) |
| 26 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC (a) One Coats |
| 27 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat). a) Normal Acrylic Emulsion |
| 28 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer |
| 29 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer )manufacture's specification) including cleaning and smoothning surface, two coats. i) Standard Quality |
| 30 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 31 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 32 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface :With super gloss (hi-gloss) - Two coats (white in shade) |
| 33 | (a) On timber or plastered surface : With super gloss (hi-gloss) (i) Two coats (with any shade except white) |
| 34 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 35 | M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. |
| 36 | (e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm |
| 37 | b) PTMT Pillar Cock - 15 mm. (Prayag or equivalent). |
| 38 | Taking out M.S. or W.I. Grills from wooden frame including cutting lugs from masonry wall and refitting the same and mending good damages after repairs. (Excluding the cost of necessary repair of damages) or doing any other necessary works. |
| 39 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately)(a) Upto area 2.5 Sq.m |
| 40 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr.For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. [Note : for estimate purpose construction wing may consider weight of 2- track Aluminium window @ 5.5 Kg per Sq.M.and 3-track Aluminiumwindow @ 6.5 Kg per Sq.M] |
| 41 | Supplying bubble free Float Glass of approved make and brand conforming to IS: 2835-1987.i) 4mm thick clear glass. |
| 42 | Dismantling artificial stone flooring upto 50mm. Thick by carefully chiselling without damaging the base and removing rubbish asdirected within a lead of 75 m. a) In ground floor including roof. |
| 43 | (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification. |
| 44 | Screed concrete on roof with cement concrete (1:2:4) including admixture of damp proof materials as per manufacturers specification laid in panels as directed including cleaning, chipping and applying cement sluury @ 1.75 Kg/SqM. Providing ghoondies at junctions with parapet etc. shapping and finishing at mouths of rainwater pipes complete with top finishing with cement punning not more than1.5mm thick,curing complete as per direction of Engineer-in-charge. (iii) 35 mm. thick ( Rate same as Artificial stone in floor ) |
| 45 | Extra for using approved H.B netting in every third layer in 16 & 17 of sub head A above in any floor |
| 46 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Length. (b) 110 mm |
| 47 | x) Bend 87.5º. b) 110 mm |
| 48 | xv) Vent Cowl (a) 110 mm Please Enable Macros to View BoQ information |