| 1 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/ Finolex/RR/ Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/ fan/ call bell points with Modular type switch (Brand Anchor Roma/ Legrand Mylink/ Crabtree) fixed on modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and lx22/0.3 as ECC Avg 6 Mtr [E20/l-i] |
| 2 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/ Finolex/RR/ Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand Anchor Roma/ Legrand Mylink/ Crabtree) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and lx22/0.3 as ECC On Board [E20/3-i] |
| 3 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. 19 mm dia 3 mm thick polythene pipe without earth continuity wire. [E3/6-a) |
| 4 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/ Finolex/RR/ Havells) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. [E9/1]2x2.5 sqmm +lx21.5 sqmm [For SP.Board, Compound Light] |
| 5 | Supply & Fixing 240 V, 2 Nos 6 A, 3 pin Modular type plug socket with 2 nos. 6A Modular type switch (Brand Anchor Roma/ Legrand Mylink/ Crabtree), without plug top on 6 Module GI modular type switch board with 6 module top cover plate flushed in wall incl. S&F switch board and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc(from SPNDB) [E-17 /3(a)+ E l 7 /4(a)+ E-17/l(b)] |
| 6 | Fixing only outdoor / street light type fluorescent light fitting or MVlight fitting complete with all accessories to be fixed / projected from the wall of the building incl. making holes / providing clampingarrangement & necy. GI reducer as required. S&F 40 mm GI pipe (!SI-Medium) quality 1.5 mts. average length having suitable bendS&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [C- 3/18) |
| 7 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: [C-4/28]i) 23 cm (9\\") |
| 8 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For GI [D-14/32(bl]i) for 23 cm Exhaust fan (9\\") |
| 9 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [C-4/29] |
| 10 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. [D-13 / 20(al] |
| 11 | Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [G-1/ l(a)] |
| 12 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled withbitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe [G-l/2(a)] |
| 13 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(l:6) of 25 cm width duly plastered with cement morter (inside) Ci hinged inspection cover of size 36.56 cm X 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [G-2/3(a)] |
| 14 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on as per GS ( for vertical run on cable duct & panel coneection) [G-2/4(c)] |
| 15 | Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 16 | Supply & Delivery of round shape false ceiling light of 18W-22Watt with glare free light distribution, with minimum luminious efficacy 100 lumen/wt. (Mk : Crompton/ Wipro/ Jaquar/ Bajaj/ Panasonic/ Philips/Surya) |
| 17 | Supply & Delivery of Desidiya 30 Meter LED Rope light for decoration-water proof decorative lights, cove lights for ceiling, interior design false ceiling chain light of 9Watt with glare free light distribution. (Mk. : Crompton/Philips/ Wipro/ Jaquar/ Bajaj/ Panasonic) |
| 18 | S & F 9/10 watt LED Lamp (Make:- Crompton/Philips / wipro/Jaquar/ Bajaj/ Panasonic/Surya) |
| 19 | Supply of 9\\"( 230mm) Speed 1370 RPM Heavy Duty Exhaust fans complete with all accessories having the following Model / Cat No.Make -EPC Electrical Pvt. Lid.) |
| 20 | Supply of 230V , 50Hz ,400 mm sweep heavy duty full metal body wall bracket fan (Cabin fan) complete with all accessories having the following Model-Torpedo (Make -EPC/Crompton) [NS] |
| 21 | S&D of 240V, minimum 30 watt or higher, LED Street Light including IP65 protection with CCT ( 5700-6500) & minimum Luminious efficacy>= 110 Lumen/ Watt. (Make : Philips/Surya/ Panasonic /Crompton/ wipro/ Jaquar/Bajaj/ Havells) |
| 22 | Taken down the existing indoor/outdoor unit after disconnecting all electrical connection, Cu pipe & other necessay step which is requirted towards safety measure and necessary arrangent to keep in the departmental store safely as per direction of EIC. |
| 23 | Re-Installation & Checking - testing - commissioning of supplied Split Type AC machines after supplying Indoor unit,Outdoor unit, back side bracket for IDU, adjustable angle iron bracket with powder coated paint for ODU and other necessary item which is required for installation as per direction of E.I.C. |
| 24 | Supply of 10 Litre water geyser of following specifacation and accessories: Closed water heater; Class - I, 230 V/ 50 Hz, AC, BEE 5 star rating, porcelain Element with Tubular incology 800 Element copper and outer container should be of Mild Steel and water proof powder coating to product from rust and corrision with the facility of Red-indicator of 'Heating' NEON Light indicator for working of water heater and with polyurethene foam with safety of Thermostat, 3 Thermal cut-out, Multi function valve & sarificial Anode, and must be protected against galvanic corrision using Megnesium sacrificial anode, manufactured in modern, automated plant using European Technology (Make -VENUS Splash/Raycold/AO [For Toilet)] (Model - Omnis WL or Similar Model) AO Smith/Bajaj/ Crompton) |
| 25 | S&F Timer Control Unit for single phase ACMachine/Compound Light assembled with - 8-way SPN DB Box (L&T/Cabtree/Legrand/Siemens/ABB) - 1 no.Digital 24 hour time switch (GIC/L&T-1 по.32A three pole contactor (L&T) 01 Centre off 2 way toggle switch-1 no.32Amp. Barirrer type terminal- 1 no.LED indicating lamp (L&T: SIL R 240V)-01 No.-01 2X4sqmm + 2.5sqmm copper wire 0.5 Mtr. with complete interconnection with auto-mannual bypass arrangement with locking arrangement incl. making/cutting door of SPN DB box for fixing arrangement of toggle switch, Locking arrangement, LED indicator etc. as required as per direction of EIC. [For compound light] |
| 26 | N.B: i) Payment will be made after availability of fund from concern Department.ii) Payment will be made as per P.W.D norms.iii) Rate should be quoted including All Taxes and Cess. Please Enable Macros to View BoQ information |