| 1 | Surface excavation n exc 30 cm deep and averaging 15 cm deep getting out in soft/loose soil complete all as specified and directed. |
| 2 | Removing excavated materials to a distance exc 250 m but not exc 500m outside defence land and depositing where directed. |
| 3 | M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone ® |
| 4 | M&L Cement concrete type C2 1:3:6 (40 mm graded stone aggregate) as in sub base, 75 mm thick finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L 50mm thick Sand Cushioning for paver block tiles over subbase all as spd and directed |
| 6 | S&F Machine pressed precast rubber moulded concrete interlocking paver block of 60 mm approved pattern shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Gradeall as directed at site. |
| 7 | M&L for cement concrete 1:2:4 type B1(using 20mm graded stone aggregate) as in blocks for hold fast, coping, benching etc. including weathering, slightly rounded or chamfered angles or throating including form work to concrete surfaces, complete all as specified |
| 8 | S&F DWCPE(SN4) 150mm dia (Internal Dia) pipes,snap fit coupler and rubber ring incl testing and laid and properly jointed laid in trenches to a level on concrete bed complete all as specified. |
| 9 | M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 metre mean radius with old size bricks, built in cement mortar 1:6, complete all as specified. |
| 10 | M&L for ready mix plaster of 15mm thick on brick or conc surfaces incl necessary cement slurry with bulk density 1.40 to 1.70 kg, water ratio 17 to 19% by weight & compressive strength as per IS 4031 part 6 applied as per manufacturer instruction.Inc. two coat of white wash lime |
| 11 | S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe 410 W ( Gde 250 quality A) incl demolition of existing items all as specified and directed. |
| 12 | Supply and fix pre painted galvalume aluminum ZINC coating GI base corrugated steel 0.5mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screw with minimum 150mm end lap and one corrugation side lap including dismantling the existing sheets complete all as specified and directed. |
| 13 | Excavation in trenches n exc 1.5 m wide and not exc 1.5 m depth for foundation shafts wells cesspits manholes etc n exc. 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft and loose soil complete all as specified |
| 14 | M&L Cement concrete (l:4:8) type D2 using 40mm graded aggregate in foundations. |
| 15 | Reinforced cement concrete type B-1(1: 2 :4) with 20 mm graded aggregate as in foundation including rafters footings foundation beam plinth beam bases for column etc basment slab under reamed piles and mass concrete |
| 16 | Reinforced cement concrete type B-1(1: 2 :4) with 20 mm graded aggregate in column pillars piers posts and struts . |
| 17 | S&F TMT bars above 10 mm dia cut out length bent to shape including cranking, bending and binding with 0.9mm dia mild steel wire or securing with clip. |
| 18 | S&F TMT bars 5 mm dia and over up to and including 10mm dia cut out length bent to shape including cranking, bending and binding with 0.9mm dia mild steel wire or securing with clip for striups. |
| 19 | S&F Form work to Rough finished surfaces of Flat concrete, sides of foundations, footing bases of sides and soffits if any of foundation and plinth beams and similar work vertical or to better. |
| 20 | S&F Form work to sides of pillars piers posts and struts piers columns and stanchions. |
| 21 | Returning ,filling in including spreading levelling watering and well ramming in layers not exc 25cm thick in soil in any depth complete all as specified and directed by Engr-in-Charge |
| 22 | M&L for 15 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:3 and finished even and fair to receive tiles without using extra cement complete all as specified. |
| 23 | Granite 18 to 20mm thick with uniform texture (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over including 15mm thick screed bed in cement mortar 1:6 polishing beveled edge of corner etc, complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F MS screw bolts (machine made) with hexagonal or square heads at one ends and screwed the other, or screwed both ends, each screwed end to be fitting with washer and one hexagonal or square nut n.exc. 5cm long and dia of shank 8 to 10 mm etc. |
| 25 | S&F mild steel tubler work as in frames of gates etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade st-240 all as specified and direcred. |
| 26 | M&L for MS Plates, plain or chequered, of any thickness as in gusset plate , cover plate etc in thickness in available sizes for Gde-Fe-410-W Gde-E-250 qulaity B all as directed. |
| 27 | Supply and fixing of MDF Slatwall Panel thick 10-15mm / Aluminium composite panel (ACP) of sheet coated mirror glossy finish thick 4-5mm/Natural wood finish of approved colour, pattern & design & as required shape like rectangular, trapezoidal or tappered shape & as per sample kept in GE office with plyvinylidence fluoride (PVDF) of flat panel that consist of two thin aluminium sheets bonded to a non-aluminium core of flat sandwich panel is a structure of three layer aluminum core boned between two sheets of required size fixed with heavy duty screws on aluminium channel of 38mm x 25mm and used for external cladding or facades particition, false ceiling, signage, etc. and top layer cutting the corner and edges. Protective film ACP is removed after installation complete as as specified and as directed. Note :- 1. The scope of works includes for (i) Supply and fixing of aluminium standared profile sections 38 x 25mm etc for vertical and horizontal members & spacing as per menufacturer or as required at site including providing and fixing connectores, flange brackets, framing profile, end caps, etc. complete all as per manufacturers instructions. (ii) Floor grouting of the complete enclouser shall be provided at every pillar element. Fixing with anchor fastners wherever required, applying jointing acessories, cutting, finishing and assembly of aluminium profiles, cutting panels to required size, providing extra framework aroung opening, etc, complete as per site requirements, specifications & as directed by Engr-in-Charge. |
| 28 | M&L for writing stainless steel (Grade -304) letters of size 10x10x4 inches incl necessary incl fixing arrangements complete all as specified and directed. |
| 29 | M&L mild steel work as in as in fencing post including necessary welding etc complete all as specified and directed. |
| 30 | S&F Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc.as directed (each line wire to be measured). |
| 31 | Demolition of plain /reinforeced cement concrete for any thickness in any position and of any discription complete all as specified and as diredted |
| 32 | M&L 75mm thick PCC (1:4:8) Type D2 (using 40mm graded crushed stone aggregate) as in sub floor complete all as specified and directed |
| 33 | S&F Machine pressed precast rubber moulded concrete interlocking paver block of 80 mm approved pattern shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Gradeall as directed at site. |
| 34 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, all as specified. |
| 35 | Roughening surfaces of old concrete floor by picking sweping clean and washing down with water to remove dust etc. complete all as specified. |
| 36 | M&L for Non - skid Coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but notexceeding 0.18 sqm, in floors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:4 complete all as directed. |
| 37 | S&F 15 mm dia GI tubing medium grade with all fitting and fixed to wall and ceiling or laid in floors etc as in horizontal or vertical surfaces upto G+5 storey bldg complete, all as specified. |
| 38 | M&L Glazed ceramic tiles in vertical surface 300 X 600 X 8mm/ 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick rendering in CM 1:4 incl Dismantling floor, hearth or wall tiling including cement mortar bedding all as specified and directed . |
| 39 | S&F in repairs vitreous China coloured European type WC with \\"P\\" or \\"S\\" trap for 100 mm bore , including connection to drain and to flushing cistern with pipe 32mm dia PVC pipe and fixing bolts complete all as specified . |
| 40 | S&F in repairs vitreous chinaware coloured wash hand basin of size 580mm x 450mm complete including , CP Waste coupling , PVC waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed by Engr in charge |
| 41 | S&F in repair plastic water closet seat cover/white closed pattern with flat bottom and cover and mild steel C hinges as per ISI complete all as specified. |
| 42 | S&F in repairs 10 ltrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, fixing with gitties embeded in wall with drilling machine etc complete all as specified. |
| 43 | S&F in repairs bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe, 15mm dia, fancy type, cast copper alloy, chromium plated long body with flange complete all as specified |
| 44 | S&F in repair fancy type chromium plated brass angle valve type suitable for 15mm bore pipe complete all as specified |
| 45 | Supply & fix in repair PVC connection pipe of 1/2\\"x18\\" size with 2 Nos brass check nuts with washers, complete all as specified. |
| 46 | S&F in repair Health faucet, CP brass with 1.50m long flexible pipe all as specified and as directed |
| 47 | S&F in repair fancy type 150mm size square brass CP shower rose with long arm all as specified. |
| 48 | S&F in repair CP grating 125mm dia, complete all as specified. |
| 49 | S&F in repairs fancy type looking mirror of size 600x450x6mm with 100 mm wide fancy type border fixed with 4 Nos stainless steel clips complete all as specified |
| 50 | S&F in repair Glass Corner Shelf 8mm thick including CP railing radius 250mm complete all as specified and directed. |
| 51 | S&F in repairs Glass shelf assembly 450mm long 150mm wide with cp railing complete all as specified and as directed. |
| 52 | S & F in repairs 15 mm dia Brass CP three-in-one wall mixer for mixing hot & cold with L bend water screwed down for iron pipe and fixed complete all as spd . |
| 53 | S & F in repairs 15 mm dia Brass CP WHB Mixer for mixing hot & Cold water screwed down for iron pipe and fixed complete all as specified |
| 54 | S&F in repair polythylene of low or high density or PVC, 32mm /40mm dia waste flexible pipe 750mm long. |
| 55 | S&F in repair brass chromium plated toilet paper holder, complete all as specified. |
| 56 | S&F in repair chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified |
| 57 | S&F in repair brass chromium plated soap dish, complete all as specified. Please Enable Macros to View BoQ information |
| 58 | S&F in repair brass chromium plated soap dish, complete all as specified. Please Enable Macros to View BoQ information |