| 1 | Dismantling all types of masonry excepting cement concrete plain or reinforced,stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. |
| 2 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m.In ground floor including roof. (a) upto 150 mm. thick |
| 3 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof. |
| 4 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 5 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] 1:3:6 proportion |
| 6 | Ordinary Cement Concrete( mix.1:1.5:3) with graded stone chips(20 mm.nominal size) excluding shuttering and reinforcement, if any, in ground floor,as per relevant I.S.Codes,Pakur variety. |
| 7 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor). (b) 25 mm. to 30 mm. thick wooden shuttering without staging in foundation. |
| 8 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation, basement, and upto roof of ground floor / upto 4m. (i) Tor steel/Mild Steel . I. SAIL/TATA/RINL |
| 9 | Brick work with 1st class bricks in cement mortar (6:1) (a) In foundation and plinth |
| 10 | (b) In Superstructure, Ground Floor |
| 11 | 125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in G.Floor. |
| 12 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within alead of 75m as directed. |
| 13 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (a) With 6:1 cement mortar 20 mm. thick plaster |
| 14 | 15 mm. thick plaster |
| 15 | (ii) With 4:1 cement mortar (a) 10 mm. thick plaster |
| 16 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. |
| 17 | Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. |
| 18 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick). |
| 19 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC (a) One Coats |
| 20 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat). a) Normal Acrylic Emulsion |
| 21 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer |
| 22 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer )manufacture's specification) including cleaning and smoothning surface, two coats. i) Standard Quality |
| 23 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 24 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 25 | (a) On timber or plastered surface : With super gloss (hi-gloss) (i) Two coats (with any shade except white) |
| 26 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface :With super gloss (hi-gloss) - Two coats (white in shade) |
| 27 | (e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm |
| 28 | b) PTMT Pillar Cock - 15 mm. (Prayag or equivalent). |
| 29 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracigs properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete,in G.Floor.(Payment will be made on the area of the gate covered by two guard rails and two extreme channels) |
| 30 | Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (a) 35mm thick shutters (single leaf) |
| 31 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 32 | M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. |
| 33 | Galvanised iron sheet ridging fitted with necessary bolts,screws, washers etc complete.(225mm end lapping)(A) 300 mm lapping each way(a) With 0.60 mm sheet |
| 34 | Supplying, fitting & fixing Industrial Troughed Aluminiumsheet (excluding the supporting frame work) of approvedmake & brand in alloy 3105 conforming to IS: 1254-1991fitted and fixed with 75 mm & 25 mm Self tapping screw ,EPDM Washer 16 mm dia & 3 mm th washer etc completewith 150 mm. end lap and one corrugation minimum side lap.(Payment to be made on area of finished work) (Aluminiumsheet to be supplied by contractor). a) With 0.65 mm thick sheet |
| 35 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. i) For roof truss works. a) Span up to 12 Mtr |
| 36 | Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] (ii) 6mm |
| 37 | (iii) 9mm |
| 38 | (iv) 12mm |
| 39 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge.The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor Glossy/Matt/Suede excluding surface texture or metallic lustre. ii) Thickness of laminate 1.5 mm |
| 40 | M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete) In ground floo |
| 41 | (A) Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete (excluding the cost of bolts, paints, but including the cost of nails, screws etc.) (The quantum should be corrected upto three decimals) i) Sal : Siliguri |
| 42 | (B) Dressed wood work in post , plate , battens . etc. fitted & fixed complete (excluding the cost of bolts only, but including the cost of nails, screws etc.) (The quantum should be corrected upto three decimals) (i) Sal : Siliguri. |
| 43 | Taking out Mirzapur or glazed porcelain tiles carefully by chiselling fromwallsor floor including stacking serviceable material as directed. |
| 44 | Supplying, fitting and fixing 1st quality Ceramic Tiles of any size in walls & floors including borders to match with the existing work & 4 nos. of key stones (10mm) witharaldite at the back of each tile & set in sand cement mortar (4:1) including backing concrete (1:2:4) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide,if required, to match the colour of tiles including roughing of concrete surface,if necessary or by synthetic adhesive &grout materials etc. (A).Floor, With sand cement mortar (1:4),20mm thick & 2mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m &joint filling using white cement slurry @ 0.20 Kg/Sq.m. i)Areaof each tile upto 0.09 Sq.m., other than coloured decorative including white. Please Enable Macros to View BoQ information |