| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil |
| 3 | M & L for PCC 1:3:6 type C2(using 40mm graded stone aggregate) in foundations, filling and mass concrete complete. |
| 4 | S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 Completely all as specified and as directed by Engineer in Charge |
| 5 | Supply only PVC coated (1mm thick) chain link fencing exc 2.00 but n.exc 3.00 kg per sqm with size of mesh 50 x 50 mm and thickness of wire n.exc 2.83 mm all as specified and as directed. |
| 6 | Fixing only PVC coated chain link fencing including fixing of line wires any mesh, size and any type of standards, rails, straining bolts etc including provision of binding wires complete.(Supply of MS line wire and flat iron bolt & nuts measured and paid seperately) |
| 7 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specifed and directed. |
| 8 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil |
| 9 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm hard/dense soil all as specified and directed by Engineer-in-Charge |
| 10 | Removing excavated material exc. 1.50 km but n exc.5 km and depositing outside MD land all as specified and directed by Engineer-in-Charge |
| 11 | M&L for Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 mm thick, watered and rammed to a true surface all as specified and directed. |
| 12 | M&L for PCC 1:3:6 type C-2 75 mm thick (using 40mm graded aggregate) as in sub base complete all as specified and directed. |
| 13 | M&L for chequered cement concrete tiles 25 mm thick set, jointed and pointed in neat cement slurry in floors with grey pigment cement with pigments including 15 mm thick screed bed in CP 1:6 complete all as specified and directed by EIC |
| 14 | M&L Pre-cast cement concrete block masonry Type C1 1:3:6 (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar, complete set in CM 1:6 |
| 15 | M&L rendering 15 mm thick on fair faces of brick work, block masonry, concrete surfaces in CM(1:4) to be finished even and smooth(using extra cement) complete all as specifed and directed by EIC. |
| 16 | M&L for preparation of new plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces |
| 17 | M&L for design mix Cement concrete work M-25 (using 20mm graded aggregate) as in floor,hard-standing etc complete all as specified and directed by EIC |
| 18 | Supply & Installation of FIH Global Certified Hockey Turf (of 800 Sqm or 8611.20 Sqft) from FIH Preferred Manufacturer having pile height of 13mm both recommended for water or sand dressed hockey international tournaments and national level tournaments, should have following specifications; Composition PE, Structure Monofilament curl, Dtex PE8000, Tape thickness 130μm±15μm, Tape width 0.8-1.0mm, Pile height 13mm±1mm, Gauge 3/16 inch, Stitches per 10cm 34±1, Stitches per m2 71400 ±100, Total yarn weight 1860g/sqm ±10%, Primary backing \\"PP + polyester fiber short-staple +, Mesh scrim inlay\\", Secondary backing Latex, Total carpet weight 3100g/sqm ±10% Installation of Turf should be done using a seam tape & suitable PU adhesive. Adhesive TDS should match the following basic properties; Colour & Form: Grass-green paste, Characteristics: 2 component polyurethane-reaction adhesive, for outdoor use.Specific Gravity: 1480 g/litre., Viscosity: Thixotropic, Solids: 100%., Application: Notched trowel or by suitable machine for applying to Seaming Tape. Warranty - 3 years on manufacturing defects in adherence to Ebaco Norms (no warranty on paint line marking) |
| 19 | M/L preparing new steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zink chrome primer all as specified and directed by Engineer-in-Charge |
| 20 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed |
| 21 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in set in CM 1:6 complete all as specifed and directed by EIC. |
| 22 | Taking down cement or cement lime plaster (of any description) on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. Please Enable Macros to View BoQ information |
| 23 | Taking down cement or cement lime plaster (of any description) on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. Please Enable Macros to View BoQ information |