| 1 | Dismantling of unserviceable centrifugal pumps from existing system of capacity 25 HP, Make Kirlosakr, driven by 18.5 KW electric motor transported to civil workshop for repairing all as specified and directed by Engr-in-charge.Note:- Deffective /Damage spare parts which are not repairable shall be supply and fix new and will be measured and paid separately. |
| 2 | Supplying and fixing in replacement of components/ spare parts suitable for pump set mentioned under BOQ item No. 01, all as specified and directed by Engr-in-charge. |
| 3 | Wear ring CI. |
| 4 | Inter stage ring CI |
| 5 | Sleeve DE/NDE CI. |
| 6 | Split lantern ring (Bronze). |
| 7 | Bearing cover DE CI. |
| 8 | Bearing cover NDE CI. |
| 9 | Bearing cover cap/plate CI. |
| 10 | Pin bush coupling pully DE/NDE CI. |
| 11 | Water Defflector (Aluminium). |
| 12 | 'O' Ring for Shaft sleeves (CI). |
| 13 | Impeller key (CI). |
| 14 | Coupling Key (CI). |
| 15 | Shaft nut (CI). |
| 16 | Gasket set. |
| 17 | Brass greasing Nipple. |
| 18 | Brass air cock. |
| 19 | Rubber spider suitable for tyre coupling. |
| 20 | Bearing cartridge DE/ NDE |
| 21 | Pump Motor steel coupling plate |
| 22 | M&L for repair of under mentioned components/spare parts as original by adding extra material required and making alignment with the help of lathe machine or any kind of machine suitable for machining pump set in item No. 01 of BOQ, all as specified and directed by Engr-in-charge. |
| 23 | Impeller Ist stage bronze. |
| 24 | Impeller IInd stage bronze. |
| 25 | Pump shaft C-40. |
| 26 | Supplying and fixing in replacement of components/ spare parts suitable for pump set mentioned under BOQ item No. 01, all as specified and directed by Engr-in-charge. |
| 27 | Impeller Ist stage bronze. |
| 28 | Impeller IInd stage bronze. |
| 29 | Pump shaft C-40. |
| 30 | Supply and replacement MS screw with bolts hexagonal or square heads at one end and screwed the other end or screwed both ends, nuts, washers, length of bolt 150mm to 225mm, dia of bolt 16 mm & above all as directed by Engineer-in-Charge. |
| 31 | S& replacement pressure gauge 0-10 Kgs/Sqcm, 4 inch dia round type including suitable size symphonic pipe connection all as specified and directed. |
| 32 | S&F in renewal of bearing No 6313 of Make SKF/NBC suitable for 25 HP, three phase induction motor all as specified and directed by Engr-in-charge. |
| 33 | S&F in renewal of cooling fan made of cast iron suitable for 18.5 KW induction motor 3 Phase all as specified and directed by Engr-in-charge |
| 34 | Supply and replacement of steel cushion vibration pad suitable for 25 HP centrifugal pump set all as specified and directed. |
| 35 | S&F in replacement PVC cables copper conductor insulated and unsheathed multistranded 3 core of size 10 sqmm 1100 V including copper lugs complete all as specified and directed. |
| 36 | S&F in replacement PVC cables copper conductor insulated and unsheathed multistranded 3 core of size 35 sqmm 1100 V including copper lugs complete all as specified and directed. |
| 37 | Taking down old unsv single phase preventer and S&F new single phase preventor automatically will correct reverse phase also protection against single phasing,over voltage protection, under voltage protection, Low voltage, high voltage with time delay, rating suitabl 25 HP as per existing sample type make or equivalent in L&T and minilac including all electric connection. All as specified and directed by Engr-in-charge. |
| 38 | M&L rewinding (renewal of winding) of induction motor of rating 25 HP, 3 Phase, 440V, 1440 RPM (make kirlosker) with super enameled copper winding wire of existing gauge including insulating materials, heating/drying and testing complete including dismantling, transportation, loading, unloading & installing in position all as specified and directed by Engr-in-charge. |
| 39 | S&F in repair MCCB 3 Pole 630 Amps, 415 volts,T6 release system ekipm-LRIU, compatibility Tmax T 36 KA complete all as specified and directed. |
| 40 | M&L for maintenance and up keeping of all pump, motor and LT panels install inside any pump and installations the contactor is deemed to provide following :-(i) checking and maintenance of all connections gauges etc of all pump sets 25 HP capacity, and endorse the status in the register.(ii) Checking and maintenance of Voltage meters, Amp meters and checking of RYB phase indicators, CTS incl all electrical connections of LT panel incl endorse the status in register. (iii)Checking and mainteance of leakage of transformer oil from starters, all connections, of moving, auxillary, contacts, coils, relays etc in all respect of oil immersed and Electronic starters. (iv) Arresting of leakage from pumps,sluice valves by filling Gland etc and make the pump set leak proof. Cont/- |
| 41 | Cont/-(v) Maintaining the allingment of pumpsets,maintaining the vibrations by filling neccessary gland packing, and allied works for avoidng the loss of pumpsets due to mechanical faults and electrical faults to prevent the motor winding burning, damage of pump shafts, coupling, casing of pump sets etc and restrict the abnormal sounds in pump sets.Note :(a) The neccessary gland packing,rubber insertion sheets, insulation tape, grease, oil and nut bolts of any size will be issued by contractor without any extra cost for maintenance. (b) T&P, helpers for repair and maintenanace are reasponsiblity of contactor without any extra cost. (c) Any defect found and not intimated by the technician will be viewed seriously and penalty of Rs 5000 or cost of deffect rectification which one is feasible will be accounted. |
| 42 | M&L and T&P for scraping/removing of complete old paint from centrifugal pumpset with eletric motor of capacity 25 HP and painting the same with two coat of synthetic supper enamelled paint over one coat of primer as existing color including writing SM/MES No complete all as directed by Engineer in charge. |
| 43 | Supply installation and fixing of Butterfly valve flanged type made of cast iron ISI Marked with handle for opening and closing suitable for pipe of dia 150 mm complete all as specified and directed. |
| 44 | Supply installation and fixing of Butterfly valve flanged type made of cast iron ISI Marked with handle for opening and closing suitable for pipe of dia 250 mm complete all as specified and directed. |
| 45 | M&L for repair of LT panel by replacement of the following items:-(panel shall be rapaired by skilled technician having good knowledge of L&T, SIEMENS,etc) |
| 46 | Copper cable PVC single core unarmoured ,unsheathed of size 2.5 sqmm |
| 47 | Ampere meter 0 to 100 Amps of existing size Make AE |
| 48 | Volt meter 0 to 500 volts of existing size Make AE |
| 49 | CTs 100/05 Amp Make AE |
| 50 | Selector switch RYB 10 Amp |
| 51 | Phase indicator R,Y,B as per existing |
| 52 | Electronic timer |
| 53 | Terminal plate |
| 54 | copper lugs ,thimbles,bottle lugs of any size |
| 55 | Electronic relay |
| 56 | AF contactor 3 pole (600 V AC) 300 A, maximum operating voltage upto 600 V |
| 57 | M&L and T&P for removing of complete old paint from MS surface (pipe and filter) and painting the same with two coat of synthetic enamelled paint over one coat of primer as existing color complete all as directed by Engineer in charge. |
| 58 | Supply and laying in replacement electrical insulation rubber matting as per ISI and size 1 mtr x 2 mtr x 19 mm suitable for electric installations / panel boards tested suitable all as specified and directed by Engr-in-charge. |
| 59 | S&F in repair MCCB 3 Pole 400 Amps, 415 volts,T6 release system ekipm-LRIU, compatibility Tmax T 36 KA complete all as specified and directed. |
| 60 | Supply and fixing in replacement of Non return valve of 200 mm, cast iron body, ISI marked, heavy duty both end flanged,suitable for 200 mm bore pipe fixed in repair/ replacement complete all as specified and directed. |
| 61 | Supply, installation, commissioning and testing in replacement of Smart Motor Protection (electronic smart relay for metering and protection with VFD) controller having feature as Protection against UV, OV, Phase loss, Phase unbalanced, Phase asymetery & auto phase polarity correction with time delay & having display of V, I, Of, Hz with iOT enabled and potential free feedback contacts suitable for 50 hp motor-3 phase induction motor with following details.(Make-Rockwell/Siemens/Schnider/AAB)Cont/- |
| 62 | Cont/-(i) E300 overload relay (193/592 IEC/Nema) group selection (ii) 2 IN / 2 Out control Module. 240V AC (iii) V/I/GF Sensing Module (.5-30A) DIN rail/ Panel Mount Power Terminals. (iv) Voltage/current/ Ground fault sensing module (1C…100A) DIN Rail/ Panel Mount with line and Load side power conductor Terminals. (v) Voltage/ Current/ Ground fault sensing module (20..200A) DIn Rail/ panel Mount with line and load side Power conductor Terminals |
| 63 | M & L for opening the door by dismantling all nut bolts and packing material without damaging any part of pressure filter of capacity 35000 Gln/hour and removing complete filter media from pressure filter and stacking it in a clean and safe place all as specified and directed. |
| 64 | M & L for refilling the serviceable media of existing quality, size and shape in engineered manner layer wise after properly cleaning,removing unserviceable media, topping up serviceable media of same size, shape, closing of door by serviceable nut bolts and packing sheet and testing it completely all as specified and directed.Note :- Media require for topping up will be measured and paid seperately under respective item of BOQ. |
| 65 | M & L for cleaning of inner shell of pressure filter of size 27500 Gln/Hr by removing dirt, mud, rusted particles, removing any blockage in the air vents and painting the inner shell and pipes completely by one coat of primer and one coat of enamel paint all as specified and directed. |
| 66 | Supply and mixing pressure filter media (sand and gravel) of washed, best quality, different size and shape as required suitable for swimming pool filter all as specified as per IS-8419 all as specified and directed |
| 67 | Supply and mixing pressure activated charcoal media of washed, best quality, different size and shape as required suitable for swimming pool filter complete all as specified as per IS-8419 all as specified and directed Please Enable Macros to View BoQ information |