| 1 | Demolition above G.L. upto floor two level including disposal of unserviceable materials wihtin 20 mtrs lead PCC work as per direction and to the entire satisfaction of the Engineer-in-charge. (upto 150mm thick) |
| 2 | Excavation in foundation and trenches etc. (in pipes and pits) in all kinds of soils such as pick work, jumper work, blasting in soft/hard rock, chiselling/wedging out of rock/where blasting prohibited)saturated soil stacking the excavated earth within all leads and lifts clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then including uprooting of trees dressing of beds, and sides and preparation of sub-grade, restoration of unmetalled/metalled/paved surfaces to its original condition including soring, strutting, timbering and dewatering where ever houses, fixing caution boards, crossing over trenches and to the entire satisfaction of the Engineer-in-charge. |
| 3 | Pick Jumper work |
| 4 | Chiselling Rock |
| 5 | Disposal of excavated unserviceable material from site of work to Nallah (upto 5Kms distance) |
| 6 | Laying and jointing in trenches centrifugally DI (Spun) Pipe Socket & spigot Class LA ( Earth work to be measured & paid for separately) 150mm Dia |
| 7 | Providing and laying cement concrete 1:4:8(1cement:4sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
| 8 | Brick work using common burnt clay building bricks of 2nd class in cement mortar 1:4 (1cement: 4sand) in all leads and lifts in foundation and plinth in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
| 9 | Providing and laying cement concrete 1:2:4(1cement:2sand:4 graded stone aggregate 20mm nominal size ) and curing complete excluding cost of form work in foundation and plinth in all leads as per direction and to the entire satisfaction of Engineer-in-charge. |
| 10 | Providing form work with steel plated 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring,shuttering,strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for insitu-reinforced concrete and plain concrete. within all leads and lifts. |
| 11 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors etc 200mm. |
| 12 | Edges of slab and breaking in floor and walls upto 20 cm wide. |
| 13 | Laying Tor steel reinforcement for RCC work including bending binding and placing in position complete upto floor two level within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge |
| 14 | Providing and laying cement concrete 1:2:4(1cement:2sand:4graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and reinforcement for reinforced concrete work in : |
| 15 | Suspended floor, roofs, landings and shelves and their support balconies beams, girders, bressumer and cantilever upto floor two level in all leads as per direction and to the entire satisfaction of Engineer-in-charge. |
| 16 | 15mm thick cement plaster in single coat on the fair side of brick/concrete /stone walls etc. interior plastering upto floor two level including arrises internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:4(1cement:4sand) in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
| 17 | Applying cement slurry on RCC slab or cement concrete work using 2.75 Kg. of cement per square meters of floor area before laying cement concrete flooring including roughening, cleaning of the concrete surfaces complete within all leads and lifts as per direction and to the entire satisfaction of Engineer in Charge. |
| 18 | Providing and fixing SFRC Man hole for frame of internal size with frame of 500mm internal dia (Medium duty). The weight of cover & frame should not be less than 58 kg. complete within all leads and lifts as per direction and to the entire satisfaction of Engineer in Charge. |
| 19 | Extra Heavy Duty |
| 20 | Medium Duty |
| 21 | Providing 200mm wide PVC insulated MS rungs with chequarred or ribbed non slip surface including fixing in manholes with 200mmx200mmx100mm cement concrete 1:3:6(1cement:3sand:6graded stone aggregate 20mm nominal size within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
| 22 | Boulder / Stone filling behind the retaining wall also under floor & upstream in all leads & lifts complete within all leads and lifts as per direction and to the entire satisfaction of Engineer in Charge. |
| 23 | Providing house connection to sewerage manhole chambers complete within all leads and lifts as per direction and to the entire satisfaction of Engineer in Charge. |
| 24 | Providing laying, heavy duty precast Cemen concrete interlocking paver blocks vibro compackted upto M-50 Grade including boulder/curb block gray/coloured over sub base of coarse sand with 25mm thick average thickness laid over including curing rubbing and polishing complete. ( Sub base concrete floor to be paid seperately) ( 40mm thick interlocking blocks.) Please Enable Macros to View BoQ information |