| 1 | Cutting of floor topping of concrete / Kota Stone /any kind of marble/ tile floor depth up to 50mm any kind of marble/ tile floor depth up to 50mm due care so that surrounding floor should no damage) to lay the tactile flooring 300mm wide including cost of providing and laying 25mm CSR 14.160 |
| 2 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) CSR 14.116 |
| 3 | Malwa shifting As per Analysis Attached |
| 4 | Providing and fixing 16 gauge stainless steel pipe of various sizes railing of grade 304 dully fixid on side wall with the help of bolts fixid with hand rail s.s square bar 25X25mm welded to MS flat 50X5mm complete in all respect as per as per specification and entire satisfaction of Engineer in Charge. (Railing along wall in ramp for ground floor to upper storey design as per guidelines issued for persons with disability) Length of the railing on both side of the ramp 50mm dia CSR 18.39 |
| 5 | SS Cap for 1\\"Grouted pipe in wallProviding & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. CSR 30.64a |
| 6 | Providing and fixing acrylic Braile indicators of size 170mmx35mm to be fixed on handrails of the approved design and ake havig Braile dots raised 0.5mm above base plate to the installed at the specific locations as per the directions of Engineer in Charge complete as per design/specifications and guidelines as perentire satisfaction of the Engineer in chargeStair and Ramp Railing Nos/10rft |
| 7 | Providing and Installation of Safety signage as per guideline for person with disability made of retro reflective sheeting as per colour specified and writing matter will be of same material in white fixed / pasted over 4mm thick aluminum composite sheet, including cost of writing matter with braille also firmly fixed on wall with nylon fastener, brass screw and washer complete as per specification and as desired by engineer in charge |
| 8 | Infomatory sign board 800X600mm rectangular with high intensity microprismatic grade retrorelective sheeting type XI as per ASTM D 4956-09 fixid over 4mm thick alluminium composite material (ACM) sheeting having alluminium skin thickness of 0.4 to 0.5mm on both sided and fixing the same with suitable size alluminum alloy rivets @200mm c/c to back support frame of 25X25X3mm angle iron supportd on a mild steel angle iron post 65X65X6mm with cost of definition plate firmly fixid to ground in foundation concrete M25 of size 0.45X0.45X0.6M FOR vertical post complete as per specification CSR 24.46a |
| 9 | Supply of Single side signage / Tactile Layout / Emergency Evacuation Layout with provision of multilingual text integral with minimum 3.8mm thick blue/white or combine Acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height not less than 20mm, raised above base plate by not less than 0.8mm and the equivalent word/s written in Hindi / any language as required with same specifications with Grade 1 Braille to be integral with the sign face and should be raised not less than 0.5mm above Acrylic base plate. (MAKE - SNOLITE) |
| 10 | Providing and laying 50mm wide antiskid tape made of slip resistant material colour contrast edge strip, self adhesive to be fixed on front edge of Stair treads to help people with visual disability and elderly even in dim light conitions & reduce risk of slipping. Make 3M or equivalent brand complete as per specifications.Harmonised guidelines for PWD and as desired by engineer-in-charge. |
| 11 | Providing and laying 25mm to 50mm wide high intensity reflective conspicuity tapecolour contrast,edge strip,self adhesive to be fixed on front edge of stair riser to help people with visual dsability and elderly even in dim light conditions and reduce the risk of slippimg Make 3M or equivqlent brand complete as per specifications. Harmonised guidelines for Pwd and as desired by engineer-in-charge. |
| 12 | MS Pipe for Fixing Board as Per AC Slip Chapter No. 3 |
| 13 | Table for Reception with one side rack (drawings) complete with 18mm plywood bothside laminated including GST. Technical Specipications as per engineer: Size: Approx. 5 ft (L) x 2.5 ft (W) x 2.5 ft (H), Material:18 mm thick BSL MDF Board, Top Surface: 18 mm thich pre-laminated board, Front Panel: Decorative laminate with modesty panel, Storage: 1. Drawer unit with central lpcking system, 2. cupbaord with shutter, Edge Banding: PVC edge banding for durability, Cable Management: Provision for wire management, Color: Standard teak/walnut/white finish (as approved), Heavy-duty hardwarge fittings |
| 14 | Chair chushioned and with arms 18 grage nikkle pipe 1\\" Frame, Technical Specipications as per engineer: Size: 480+_10mm (w) 400+_10mm, Height: overall height = 450 mm - 480 mm, Depth: 500 mm - 575 mm, Weight: around 100 - 100 kg |
| 15 | Electric Wheel Chair, Technical Specipications as per engineer: Frame: Hreavy-duty MS powder-coated frame, Motor: Dual motor 250W x 2 (500W total), Battery: 24V (12V x 2), 20AH reachargeable battry. |
| 16 | Wheel Chair Hand Operate, Technical Specipications as per engineer: Frame: MS powder-coated foldable frame, Seat Width: 18 inches, Seat & Backrest: Bylon/Leatherette washable upholstery, Armrest: Fixed padded armrest, Footrest: Swing-away detachable footrest |
| 17 | Lift WellEarth work in excavation in foundations trenchesetc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 18 | Cement concrete 1:4:8 with brick balast 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 19 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 20 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 21 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. Beams |
| 22 | Extra Rate for 1st Floor |
| 23 | Extra Rate for 2nd Floor |
| 24 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) Ground Floor and First Floor |
| 25 | Extra Rate for 1st Floor |
| 26 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. Ground floor and First Floor |
| 27 | Extra Rate for 1st Floor |
| 28 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. Third Floor |
| 29 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. Ground floor and First Floor |
| 30 | Extra Rate for 1st Floor |
| 31 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. 2nd Floor |
| 32 | Extra Rate for 3rd Floor |
| 33 | 12.5 mm thick cement plaster 1:5 |
| 34 | 20mm thick cement plaster 1:5 in two coat work |
| 35 | 12.5 mm thick cement plaster 1:4 |
| 36 | 20mm thick cement plaster 1:4 in two coat work |
| 37 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including jointing with seal ring (i) Single socketed pipes.U-PVC pipes (working pressure 4 kgf. / sqcm) Single socketed pipe 110 mm dia. |
| 38 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend. |
| 39 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as perspecifications and to the entire satisfaction of Engineer- in- charge. |
| 40 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 41 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 42 | Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating (P.T.M.T.) |
| 43 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean afterwire brushing |
| 44 | Extra Rate for 2nd Floor |
| 45 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 46 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 47 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 48 | Extra Rate for 1st Floor |
| 49 | Extra Rate for 2nd Floor |
| 50 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 51 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties andscrew on vertical expansion joints one side fixed and one side fixed with slotted holes to allowmovement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 52 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 53 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 54 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm Please Enable Macros to View BoQ information |