| 1 | Earth work in excavation of foundations of bridges culverts, buildings in cluding handling of material with a combined leadof 15 metresdressing of bed andsides stacking the excavatedsoil from the edge of excavation and subsequent filling (a) For ordinary gravel soil involving pick work |
| 2 | Cement concrete 1:3:6 mixing by mechanical means using concretemixer volumetric type |
| 3 | Cement concrete 1:4:8with stone ballast 20mmgauge mixing by mechanical means |
| 4 | First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth. |
| 5 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level |
| 6 | 20mm thick cement plaster 1:4 in two coat work |
| 7 | 12.5 mm thick cement plaster 1:4 in two coat work |
| 8 | Reinforced cement concrete M-25mechanically batchmixed using batch typeconcretemixer asper IS:1791andvibratedby needle vibrator but excluding steelreinforcement centring and shuttering infoundation and plinth |
| 9 | Reinforced cement concrete M-30mechanically batchmixed using batch typeconcretemixer asper IS:1791andvibratedby needle vibrator but excluding steelreinforcement centring and shuttering infoundation and plinth |
| 10 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 11 | Reinforced cement concrete M-30mechanically batchmixed using batch typeconcretemixer asper IS:1791andvibratedby needle vibrator but excluding steelreinforcement centring and shuttering insuperstructure. |
| 12 | Cement concrete 1:2:4 mixingbymechanicalmeansusingconcretemixer volumetric typewith stone ballast 20mm gaugeWith stone ballast or shingle mixing by manual means |
| 13 | Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete |
| 14 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 15 | Centering and shuttering for sides and soffits of beam,launching girders, bressumers, lintels. |
| 16 | Centring and shuttering for columns(Square or Rectangular) |
| 17 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 18 | Preparationof plasteredor concretesurfacefor painting (including sand papering thesurface)usingAcryllicWallPutty byapplyingtwo or more coats to get required finishincluding priming coat to make an evensurfacebeforeapplyingAcrylicwall puttyonnew plastered surface.Complete as perspecifications |
| 19 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 20 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied@ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 21 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in charge. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per mete |
| 22 | Wire gauge fixed on steel windows of std. rolled section with 3 mm flat iron cover moulding of 12.5 mm width complete in all respect. |
| 23 | Providing & Fixing 14 gauge MS sheet garage door with 40x40x6mm angle iron framed i/c locking arrangmets with handles etc. complete in all respect. |
| 24 | Supplying and fixing rolling shutters, ofapproved make, made of 80mmx1.25mm,M.S. Laths, interlocked together throughtheir entire length and jointed together, atthe end, by end locks, mounted onspecially designed pipe shaft, withbrackets, side guides, 27.5cm long wirespring grade No. 2 and arrangement forinside and outside locking with push andpull operation complete, including topcover 0.80mm thick (payment is to bemade for the exact size of opening whererolling shutter is to be fixed) |
| 25 | Base course of floor consisting of 100 mm thick cc 1:8:16 100 mm sand filling |
| 26 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ).(600mm x600 mm) |
| 27 | Providing & Fixing 1st quality Glazed Tiles 310x450 mm as approved by the Engineer-in-incharge over 12 mm thick cement plaster 1:4 in base an joined with grey cement slurry@3,3 kg per sqm complete. |
| 28 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in Dark fast Colour and pattern over and including 40 mm thick compacted bed |
| 29 | Providing Advanced direction Sign Board 1200x1800 mm rectangular as per IRC 67-2012 with retro reflective high intensity grade sheeting fixed over 2 mm thick alm sheet with 25x25x3mm angle complete in all respect. |
| 30 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge |
| 31 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Size 550 mm x 400 mm x 815 mm |
| 32 | Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect. |
| 33 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect |
| 34 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P. brass towel Rails size 15mm dia610mm long |
| 35 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 36 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 600mmx450mm |
| 37 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock foam flow without flange |
| 38 | Providing & Fixing in postion stop cock / Anglevalve of approved make (to the approval ofEngineer-in-charge ) complete in all respect.C.P.brass 15mm Angle valve withoutflange |
| 39 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x300 mm with C.P. Brass nut |
| 40 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.(a) With C.P. Brass nut |
| 41 | Cutting chase in brick walls in cement or in floorfor embedding G.I. or C.I pipes line and makinggood the same to its original condition. Size 75 mm x 75 mm |
| 42 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittingsand base support for tank (i) Triple Layer Tanks |
| 43 | Providing&fixinginpositiononterrace(atall floor levels) HDPE tank cover for water storage tanks of approved make (to the approval of Engineer-in-charge) complete in all respect For 500 l tank |
| 44 | Providing and fixing in position G.I. Tank Nippleof approvedmake (to theapproval of Engineer-in-charge) in PVCWater storage tanks complete in all respect. G.I. tank nipple 20mm i/d |
| 45 | Providing and fixing in position automatic brassBall Cock in tanks.B Brass Ball Cock with rod and Plastic Ball (ii) 20 mm i/d |
| 46 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 47 | Providing, fixing and jointing ISI Marked Gun Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. (b) 20 mm i/d Gun Metal peet valve heavy pattern. |
| 48 | Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects |
| 49 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. a)110 mm o/d |
| 50 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipesasper IS15778(ISImarked with the prior approval of Engineer-in Charge),havingthermalstabilityforhot& cold water supply, including all CPVC plain&brass threaded fittings i/c fixing thepipewithclamps at 1.00mspacing includingjointingofpipes&fittings,with onestepCPVCsolventcementandtesting of pipes complete as per direction of Engineer-in-Charge. SDR11CPVCpipes&fittings20mm o/d |
| 51 | INTERNAL- EXPOSED ON WALL : ProvidingandfixingChlorinatedPolyvinyl Chloride(CPVC)pipesasperIS15778(ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, includingallCPVCplain&brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointingof pipes&fittingswithonestep PVCsolvent cement andtestingofpipes completeasperdirectionofEngineer-in Charge. SDR11CPVCpipes&fittings20mm o/d |
| 52 | EXTERNAL INTHEGROUND : Providing and fixingChlorinatedPolyvinylChloride (CPVC)pipesasper IS15778(ISImarked with the prior approval of Engineer-in Charge),havingthermalstabilityforhot& coldwatersupplyincludingallCPVCplain &brass threaded fittings. This includes jointingof pipes&fittingswithonestep CPVCsolvent cement,&testingof joints excludingcostofexcavationcompleteas per direction of Engineer-in-Charge. SDR11CPVCpipes&fittings20mm o/d |
| 53 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete1:2:4benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspectionchambercoverandframe(Weight as per I.S.I specifications) painted with 3 coatsofblackbitumasticpaintconformingto I.S.I complete as per standard design c)600mmx900mminsidewith455mmx455mm cover and frame light duty double seal |
| 54 | Constructing soakpit1.20x1.20x1.6mdeep, 230mmthick1:5brickworkhoneycombwith bricks of Ist Class filled with brickbats includingS.W. drainpipe100mmDiametre and1.20m longcompleteasper standard design |
| 55 | Providingand fixing inpositionsingel socket SWRUPVCsoilwasteorantisyphonagepipes asper IS13592ofE.D.Cmanufactureor of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A d) 90 mm o/dsinglesocket SWRUPVC pipe lines laid complete |
| 56 | Providingand fixing inposition15mmC.P. Pillarcock foamflow ofapprovedmake(to the approval of Engineer-in-charge) |
| 57 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes(FourwayPVC1½\\"deepfor wallsandCI3\\"deepforceiling),bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface) Wiring fan point (With fan box) |
| 58 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes(FourwayPVC1½\\"deepfor wallsandCI3\\"deepforceiling),bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface) Wiring light point |
| 59 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes(FourwayPVC1½\\"deepfor wallsandCI3\\"deepforceiling),bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface) Wiring 6Amp. wall socket point |
| 60 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes(FourwayPVC1½\\"deepfor wallsandCI3\\"deepforceiling),bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface) Wiring 16/20Amp. power plug control point |
| 61 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavygaugePVCconduitpipe20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required forsuitablenumberof modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp.Switches,16/20Amp.switcheswith indicator etc. andcoveredwithFramePlate etc., PVCconnector (For FanBoxandCall Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junctionBoxes(FourwayPVC1½\\"deepfor wallsandCI3\\"deepforceiling),bondingto earthwithPVC insulatedcopper conductor singlecoreFRcable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plugcontrol point) andotherpettymaterial etc., including the cost of abovematerial, cutting and filling up of chases (with finishing the surface) Wiring light point with double control switches. |
| 62 | DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal DoubleDoorDistributionBoards IP43 IK09metal door (dustprotected) asper IS8623-1&3, IEC61439-1&3suitable for flush mounting with fully insulated copperbusbars, shroudedneutral bars, earthbars,cementspillprotector,color coded interconnecting wire set, cable ties, blanking plates and circuit identifications label andof requiredno. ofways formounting miniaturecircuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/RCCB's/RCBO'sasincomerand SPMCB's asoutgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer andSPMCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc SP&NDoubleDoorDistributionBoard8way each |
| 63 | MINIATURE CIRCUIT BREAKERS SupplyanderectionofMiniatureCircuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacityof 10kA,Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existingMCBdistributionboardasper PWDGeneral Specifications including connections with suitable size of thimbles/lugs: MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 64 | MINIATURE CIRCUIT BREAKERS SupplyanderectionofMiniatureCircuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415volts 50cycles AC supply with breaking capacityof 10kA,Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existingMCBdistributionboardasper PWDGeneral Specifications including connections with suitable size of thimbles/lugs: MCBSinglePole50,63amp. (10kA,Curve C) |
| 65 | SupplyanderectionofPVCinsulatedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 1sq.mm (Un-sheathed) |
| 66 | SupplyanderectionofPVCinsulatedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 1.5sq.mm (Un-sheathed) |
| 67 | SupplyanderectionofPVCinsulatedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 2.5sq.mm (Un-sheathed) |
| 68 | SupplyanderectionofPVCinsulatedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 4sq.mm (Un-sheathed) |
| 69 | SupplyanderectionofPVCinsulatedFR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990leftbareinpipeorcasingof suitablesizecomplete inall respect as desired by the Engineer-in-charge: Overall size 6sq.mm (Un-sheathed) |
| 70 | Providing & fixing make ISI marked Cast steell class 300 Sluice valve Dia 250 mm SS flanges, Champion rubber join, jointing, testing, and all carriage etc all SS fittings complete in all respect . Quality as per satisfaction and with the approval of Engineer-In-Charge |
| 71 | Providing,Stringingout, cutting, Jointing and testing of ISIMarkedD.I.Pipe(S&S)asper IS8329and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring (A) D.I. Pipe as per IS 8329 DI-K7 (e)250mm i/d pipe lines laid complete. |
| 72 | Providing,Stringingout, cutting, Jointing and testing of ISIMarkedD.I.Pipe(S&S)asper IS8329and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring (A) D.I. Pipe as per IS 8329 DI-K7 (f)300mm i/d pipe lines laid complete. |
| 73 | Providing and fixing LED Batten 36W |
| 74 | Providing and fixing Flood light 100 w |
| 75 | Providing and fixing Fans roof slab 48\\" |
| 76 | providing and fixing propeller type heavy exhauset fan(450mm ) |
| 77 | Providing and fixing Invertor(1300 Va) & Battery (250 ah) complete in all respect with satisfaction of engineer incharge. |
| 78 | Providing and fixing LED bulb 20W |
| 79 | Providing & fixing make ISI marked Cast steel class 300 NRV Dia 250 mm including SS flanges, Champion rubber join, including jointing, testing, and all carriage etc all SS fittings complete in all respect. Quality as per satisfaction and with the approval of Engineer-In-Charge. |
| 80 | Providing and fixing electro-magnetic digital flow metre of dia 250mm as approved by Engineer Incharge |
| 81 | Providing Supplying & fixing of Vaccum Pump 5HP |
| 82 | Providing, fixing, testing & commissioning of Electrically driven horizontal split casing non-cloggingcentrifugal pumps for delivering 90 LPS clear/raw water against a Head of 48 metre with CI casing and CF8M impeller SS shaft and coupled on MS fabricated base frame including cost of foundation bolts, flexible coupling & coupling guard & other contingent material fixed in position coupled with Electric Squirrel Cage Induction Motors of suitable Rating commensurate to the capacity of pump at 1450 RPM complete in all respects. The pump shall be compatible while operating with VFD. |
| 83 | Providing, fixing, testing & commissioning of Electrically driven horizontal split casing non-cloggingcentrifugal pumps for delivering 109 LPS clear/raw water against a Head of 37 metre with CI casing and CF8M impeller SS shaft and coupled on MS fabricated base frame including cost of foundation bolts, flexible coupling & coupling guard & other contingent material fixed in position coupled with Electric Squirrel Cage Induction Motors of suitable Rating commensurate to the capacity of pump at 1450 RPM complete in all respects. The pump shall be compatible while operating with VFD. |
| 84 | Providing, fixing, testing & commissioning premium make LT panel (TTA Type) having 1000A Four Pole ACB, 50kA micro-processor based motorized ACB with electronic trip unit, protections againts overload, short-circuit, earth fault etc with display including 6 nos starter panels having VFD-100 HP Heavy Duty with in built choke with bypass star-delta starters option having suitable contractors, digital ECOR, phase sequence relay, suitable rating MPCB/MCCB and 6 nos DOL - 5HP starters for vaccum pumps (with suitable rating of MPCB) for Riser-1 and 2. Isolation/Control Transformer of rating - 250VA , 415/230 Volt (for individual feeder) for control supply complete with Ampere meter, volt meter etc. Feeders for Lighting Load included. As per specification document (enclosed) with UPS of suitable capacity (3 KVA) with 6 hrs battery backup. |
| 85 | Supply, Erection, Testing & Commissiong of 800 kVA Transformer - 11kV/0.433kV as specifications attached conforming to IS 1180 part 1 (2014) and IS 2026 (with latest ammendments). |
| 86 | APFC Capacitor Panel of 270KVAR capacitors (in steps) for improving power factor upto 0.99 lagging having APFC relay with detuned reactors and capacitor duty contactors & having IS 13340 or latest relevant IS compliant. |
| 87 | Supply, Erection, Testing & Commissiong of 11 KV VCB Panel - having 800 Amp, 26.1kA drawout type VCB with numeric O/C and E/F relays and IEC 61850 compliant with, PT, CT (suitable for 800kVA transformer), protection relays (buckolz relay, master trip relay etc), power pack, energy meters, indicators, alarm announcitors. |
| 88 | Providing & fixing of mtc. Free (chemical) Earthing with GI strip of suitable size ( 50*5 mm) for all HT/ LT breakers, feeders panels, transformer and motros/pumps conforming to IS 3043: 2018 and IS 735 etc. having two seprate earthing pits for HT & LT. Earth resistance equal to or less than 1.0 ohm with GI electrode. |
| 89 | Erection, installation, testing and commissioning of cabling works (for above Proposed items at Sr. no 1 to 6) having suitable sizes and ratings XLPE LT cables between motors and panel, transformer LT side to panel, 11 KV HT XLPE cable from metering unit (CTPT unit) to transformer panel and from VCB panel to transformer (HT Side) etc conforming to IS 7098 Part1 & PVC Sheated conforming to IS 5831/1984 with latest ammendments and cables shall have aluminum conducter H2 grade as per IS 8130/2013 (armoured/unarmoured). Both LT & HT Cables should be drawn into trenches/racks & clamped properly. |
| 90 | MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCBs of various sizes 2/3 pole for circuit protection against overload and short circuit current fault suitable for 240/415volts 50cycles AC supply with breaking capacityof 10kA, Curve-Cand lowwatt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs: (b) MCB Single Pole50,63amp. (10kA,Curve) |
| 91 | Providing and fixing in position Cast IronFoot valves flanged ends with rubber sheat as per IS4038 including cost of Nut Bolt , rubber insertion complete in all respect (300mm i/d Cast Iron Foot valves) |
| 92 | Providing and fixing of FIREEXTINGUISHER,CO2typeasper IS:15683complete with all accessories as perManufactures Specification. ISI Markcomplete in all respect. (B) 3 Kg. Capacity |
| 93 | Providing,laying,fixing,testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts,gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including costof primer etc. excluding cost of excavationand refilling complete in all resepcts. 200mm internal diameter |
| 94 | Proving, supplying and fixing Fully electric operated 5 tonne gantry crane with traveller beam including all fittings and accessories complete in all respects as per approved Engineer Incharge. |
| 95 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing inposition |
| 96 | Any Other Items Please Enable Macros to View BoQ information |