| 1 | Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspection charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988.(MJP SSR It.No. 1 e) NP-III CLASS a) 600 mm dia |
| 2 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) (MJP SSR P.No.42, It.No.1) |
| 3 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd- A-2/259) (MJP SSR P.No.42, It.No.2) |
| 4 | Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 m beyond the area and lifts as below, staking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling etc., complete. (MJP SSR P.No.42 It.No.5) |
| 5 | Lowering, laying and jointing in proper and alignment R.C.C. pipes with collar joints in C.M. 1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubbering or R.C.C. collar), including cost of coveyance from stores to sight of works, cost of jointing material, labour, giving hydraulic testing, etc. complete as directed by enginer incharge.(MJP SSR It.No.2) |
| 6 | Filling in plinth and floors murum bedding in trenches with available murum for foundation in 15 cm to 20 cm layer including watering and compaction complete.(MJP SSR P.No.45 It.No.16) |
| 7 | Storm Water chamber with precast steel fibre reinforced concrete frame and covers (S.F.R.C. frame and covers) Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion precast S.F.R.C. frame and cover, etc. complete as directed by Engineer-in-charge. (MJP DSR P.No.284 It.No.3 A) Note : Wall thickness : 0.23 M for depth of 1.2 M and 0.35 M for balance depth exceeding 1.2 M. As above of 90 x 90 cm internal size and depth upto 0.9 M with S.F.R.C. frame and cover. |
| 8 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete(MJP SSR P.No.45 It.No.15) |
| 9 | Disposing of excavated stuff of any kind from site to work to any place which is within a lead of 3.0 Km as directed etc. complete.(MJP SSR P.No.31 ) |
| 10 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15cm to 20cm thick including hand packing and compacting etc. complete. (SSR I.No. 21.38) |
| 11 | Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of t rap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) (SSR. I. No. 24.01) |
| 12 | Providing, Supplying and Fixing in position approved quality Precast RCC U drain with RCC heavy duty gratings over U Drain of internal size 450 X 450 X 2000 , precast, casted in CC M40 with steel rainforcement, including transportation loading, unloading, filling on a soft bed of crust sand in proper line and level including PCC M-10 bed as directed by Engineer In-charge. Pre Approved Siddhivinayk precast or Super Cement Articles are only to use |
| 13 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 95 cm x 95 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge. SSR Item No 6.36 Please Enable Macros to View BoQ information |