Name of Work:- PROVN OF RECD ON VARIOUS TYPE DG SET AT INS UTKROSH UNDER GE MINNIE BAY, SRI VIJAYA PURAM
Sl. No.
Item Description
1
Design, supply, install, test and commissioning of Retrofitted Emission Control Equipment / Devices (RECD) having a minimum specified Particulate Matter (PM) capturing efficiency of 70%, type approved by one of the five Central Pollution Control Board (CPCB) recognized labs consisting of RECD with control panel, foundation frame, necessary PCC foundation , cabling, necessary addition/alterations to existing exhaust pipe of any size/qty including cutting for connecting to RECD with necessary fittings/pipe and taking out exhaust to outside, including wrapping up of asbestos rope on complete exhaust and then with aluminium sheet over asbestos wrapping, supporting steel structure for RECD & exhaust pipe complete, any other alteration to diesel engine for proper functionality of engine, testing of smoke exhaust before and after installation of equipment, including checking/inspection of functionality of RECD device once in six months during defect liability period and submission of test report for every six months, testing of DG set on existing connected load for minimum 12 Hrs for ascertaining DG functionality & fuel consumption after installation of RECD equipment complete all as specified and as directed by Engineer in Charge for following capacities of DG set :-
2
320 KVA DG Set
3
250 KVA DG Set
4
200 KVA DG Set
5
62.5 KVA DG Set
6
Note for item No 1 to 1.02 :(i) Retrofitted Emission Control Equipment / Devices (RECD) having a minimum specified Particulate Matter (PM) capturing efficiency of 70%. (ii) The RECD must be type tested by one of the five currently CPCB recognised/ approved labs: -(a) Automotive Research Association of India, Pune (Maharashtra).(b) International Centre for Automotive Technology, Manesar (Haryana).(c) Indian Oil Corporation, Research and Development Centre, Faridabad(Haryana).(d) Indian Institute of Petroleurre,\ Dehradun (Uttarakhand).(e) Vehicle Research Development Establishment, Ahmednagar(Maharashtra) or if any additional Labs are as approved by CPCB.(ii) Contractor shall submit GA drgs alongwith specification, approval letter by one of the five Central Pollution Control Board (CPCB) recognized labs for approval of GE before placing order.(iii) The emission limits after installation of RECD shall be strictly comply to latest CPCB norms and as per E-in-C's Branch, Integrated HQ of MoD (Army), Kashmir House, Rajaji Marg, New Delhi letter No A/37696/Gen/Pol/E2W (PPC) dated 29 June 2022. Please Enable Macros to View BoQ information
7
Note for item No 1 to 1.02 :(i) Retrofitted Emission Control Equipment / Devices (RECD) having a minimum specified Particulate Matter (PM) capturing efficiency of 70%. (ii) The RECD must be type tested by one of the five currently CPCB recognised/ approved labs: -(a) Automotive Research Association of India, Pune (Maharashtra).(b) International Centre for Automotive Technology, Manesar (Haryana).(c) Indian Oil Corporation, Research and Development Centre, Faridabad(Haryana).(d) Indian Institute of Petroleurre,\ Dehradun (Uttarakhand).(e) Vehicle Research Development Establishment, Ahmednagar(Maharashtra) or if any additional Labs are as approved by CPCB.(ii) Contractor shall submit GA drgs alongwith specification, approval letter by one of the five Central Pollution Control Board (CPCB) recognized labs for approval of GE before placing order.(iii) The emission limits after installation of RECD shall be strictly comply to latest CPCB norms and as per E-in-C's Branch, Integrated HQ of MoD (Army), Kashmir House, Rajaji Marg, New Delhi letter No A/37696/Gen/Pol/E2W (PPC) dated 29 June 2022. Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.