| 1 | Wiring |
| 2 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 3 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 4 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 5 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 6 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 7 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 8 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 9 | 90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 10 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 11 | SITC of AC unit |
| 12 | OD228952/2023-2024:Supply, Installation, Testing, and Commissioning of 1.5 TR High-Efficiency Wall-Mounted Split Air Conditioner. The unit shall be a 5-Star rated Inverter model with an ISEER value > 5.0, delivering a certified cooling capacity of ? 5275W. The system must utilize an Inverter Rotary Compressor optimized for 230V Single Phase AC, operating on eco-friendly, non-CFC R32 or R410A refrigerant. The unit must feature 100% Copper Condenser and Evaporator coils for superior heat transfer and corrosion resistance. Functional requirements include cooling, dehumidification, air circulation, and air filtration, managed via microprocessor controls and a cordless remote. The installation includes up to 3 meters of copper refrigerant piping, interconnecting power/signal cables, and high-density nitrile insulation (additional lengths to be measured separately). It is required to provide a 36-month comprehensive warranty and maintenance period from the date of commissioning, covering all labour, spare parts, gas charging, and quarterly preventative services. A formal warranty certificate and AMC certificate from an approved manufacturer must be submitted upon completion. (Approved manufacturer: Blue Star, Carrier, Mitsubishi, Hitachi, or Daikin) |
| 13 | OD228955/2023-2024:Supply and installation of automatic stabilizer suitable for 1.5 TR AC unit with working voltage range of 170 V - 270 V AC, current capacity of 12A, indicators, suitable for wall mounting etc. as required. (V-Guard VG 400 or equivalent) |
| 14 | OD228953/2023-2024:Supply and fixing of 25 mm outer dia. 10kgf cm2 PVC pipe along with all required accessories in surface/ recess including cutting the wall and making good the damages etc. as required |
| 15 | OD228954/2023-2024:Supply and providing following size soft drawn Copper pipe for connecting outdoor and indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc. 1/4"(6.35mm) and 1/2"(12.7mm) - 22 gauge |
| 16 | OD228961/2023-2024:Supply and providing bracket for fixing the Air conditioner unit. |
| 17 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 18 | 90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm |
| 19 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top Please Enable Macros to View BoQ information |