| 1 | CIVIL WORKS |
| 2 | 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 3 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete |
| 5 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 6 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 8 | OD385412/2025-2026 Fabrication, supply, conveyance & installation of ACP name board indicating the cost involved, the commencement, completion and inauguration date etc.(Excluding the cost of frame work). |
| 9 | ELECTRICAL WORKS |
| 10 | 90.15.3.2 Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters |
| 11 | 90.15.4.7 Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. |
| 12 | 90.14.5 Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 13 | OD385394/2025-2026 Supply and Installation of dust, weather and vermin proof Single phase Sintex Outdoor meter board of approved brand & make and to fix KSEB meters, fuse units, body material- FRP/Fiber/equivalent, Size- 30x40x15cm etc. or above, as required, including fixing it on wall, making good the damages, colour washing etc., as required. |
| 14 | OD385371/2025-2026 Supply and installation of a Digital timer, operating at 220-250 VAC, 50Hz, with a 25A/1.5HP capacity. It features 5 On/Off program settings for daily and weekly schedules, along with manual start, ON delay, and OFF delay settings. |
| 15 | OD385372/2025-2026 Supply and installation of a double pole 25A Contactor, rated for 220-250 VAC, 50Hz operation. It can control street lights, light boxes, neon lights, high/mini mast systems, and induction loads. |
| 16 | OD385373/2025-2026 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 2.5 sq. mm |
| 17 | OD385369/2025-2026 Supply and installation of an IP20 Surge Protective Device (SPD) with suitable fittings for a distribution box or MV panel. |
| 18 | OD385370/2025-2026 Supply and fixing HRC fuse base of 32 A using suitable nut and bolt, 32 A 2- way neutral links mounted on DMC/SMC base. |
| 19 | 2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), 25 amps |
| 20 | 2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load, Single pole |
| 21 | 2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 22 | OD385374/2025-2026 Supply and installation of 2.5 Sqmm non-insulated CP-1 pin terminals with suitable size heat shrink |
| 23 | 90.6.5.12 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables 3 core 2.50 sq mm |
| 24 | 90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables 3 core 1.50 sq mm |
| 25 | OD385368/2025-2026 Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, masonry enclosure and watering pipe etc. |
| 26 | 90.16.1.3 Supply and drawing bare earthing conductors 3.15 mm copper conductor (10 SWG) |
| 27 | 90.16.5.3 Supply of superior quality copper earth socket 3.15 mm (10 SWG) |
| 28 | 90.12.1.13 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable 3 core 6 sq mm |
| 29 | 90.12.9.2 Supplying, laying and jointing of double wall corrugated (DWC) pipes made out of HDPE 50/38 mm or nearest size |
| 30 | OD385367/2025-2026 Supplying and making end termination with brass compression gland and aluminium lugs 3 X 6 sq. mm (19mm) |
| 31 | Connection charges - KSEB Please Enable Macros to View BoQ information |