| 1 | DSR Item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 2 | Group C |
| 3 | DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 3 x 2.5 sq. mm |
| 6 | 3 x 4 sq. mm |
| 7 | DSR item No.1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 8 | 5/6 A switch |
| 9 | 3 pin 5/6 A socket outlet |
| 10 | 15/16 amps switch |
| 11 | 6 Pin 15/16 A. socket outlet |
| 12 | DSR Item No. 1.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. |
| 13 | DSR Item No. 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. |
| 14 | DSR item No.1.57 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 15 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 16 | Single pole |
| 17 | Double pole |
| 18 | Triple pole |
| 19 | DSR item No.9.2.4 Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, (As per Complete Item No. 5 of the DNIT). |
| 20 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 21 | DSR Item No.5.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. |
| 22 | DSR item no. 8.9.5LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, (As per Complete Item No. 11 of the DNIT). |
| 23 | 18- 22 watt |
| 24 | 36 watt |
| 25 | DSR item No.8.6.10LED Panel lm/Watt) light 1'x4' (System lumen efficacy ≥105<120.Supplying, installation, Testing & Commissioning of Panel light 1'x4', of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 12 of the DNIT). |
| 26 | System lumen efficacy ≥105 <120 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (As per Complete Item No. 13 of the DNIT). |
| 27 | 36 Watt |
| 28 | DSR item no. 8.13.12LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, (As per Complete Item No. 14 of the DNIT). |
| 29 | 50 watt |
| 30 | S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. (As per Complete Item No. 15 of the DNIT). |
| 31 | DSR item No.5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 32 | Supply and Erection of B.L. Holder of make Anchor Panta / Havells Reo/ Gold Medal Essenza ISI marked on existing Jn. Box / Wooden block including making connection etc. as required. |
| 33 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, (As per Complete Item No. 18 of the DNIT). |
| 34 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make HDEF EXHD 300-6-1/ Bajaj make Supreme PLUS/ Usha (Turbo HDEF) only |
| 35 | Size 18” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make HDEF EXHD 450-6-1/ Bajaj make Supreme PLUS/ Usha (Turbo HDEF) only |
| 36 | DSR Item No.2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) |
| 37 | 8 way, Double door |
| 38 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator). |
| 39 | 4 way (4 + 12) Double door |
| 40 | Supply and laying of XLPE insulated PVC sheathed Aluminium conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid direct on surface with the help of M.S. clamp of suitable thickness. (As per Complete Item No. 21of the DNIT). |
| 41 | Size 10 Sq.mm 2 Core XLPE Al. Arm. Cond. Cable |
| 42 | DSR Item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 43 | 25 mm |
| 44 | S/E of GI pipe bracket of 32 mm dia welded with nipple for erection of existing street light fittings to be installed on wall with suitable size of rag bolts and MS clamps made out of 25 mmx 5 mm thick MS flat with all labour and material. (As per Complete Item No. 23 of the DNIT). |
| 45 | S/I/T/C of LED Highbay luminaries of Philips/ Wipro/ Bajaj/ LT/ Jaquar/ Havells/ Crompton/ Panasonic/ Keselec/ Surya make only. The job includes the cost of testing, (As per Complete Item No. 24 of the DNIT). Please Enable Macros to View BoQ information |