| 1 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground with all leads and lifts including finishing even and smooth and curing complete as per direction of the Engineer in charge:With cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 2 | Dismantling GS sheet roofing including ridges, hips,valleys, gutters wind ties etc. includingdismembering and stacking of serviceable materialsand unserviceable materials separately with all liftsand upto a lead of 50 m etc.complete as per directionof the Engineer- in-charge. |
| 3 | Demolishing cement concrete manually / bymechanical means including disposal of materialwith all lifts and upto 50 m lead etc. complete as perdirection of the Engineer- in-charge:-Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 4 | Dismantling doors, windows and clerestory windows(steel or wood) shutter including chowkhats,architrave, holdfasts etc. complete and stackingwithin 50 metres lead :Of area 3 sqm and below |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kind of soil |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. All kinds of soil |
| 7 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 8 | Providing and laying in position cement concrete ofspecified grade excluding the cost of centring andshuttering -All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) |
| 9 | Providing corrugated G.S. sheet roofing includingvertical/curved surface fixed with polymer coated Jor L hooks, bolts and nuts 8 mm diameter withbitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead and including a coatof approved steel primer and two coats of approvedpaint on overlapping of sheets complete (up to anypitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses andincluding cutting to size and shape wherever requiredetc. complete as per direction of Engineer-in-charge.0.63mm thick with zinc coating not less than 275gm/m2 |
| 10 | Providing ridges or hips of width 60 cm overall widthplain G.S. sheet fixed with polymer coated J or L hooks,bolts and nuts 8 mm dia G.I. limpet and bitumenwashers etc. complete as per direction of Engineer-incharge.0.63mm thick with zinc coating not less than 275gm/m2 |
| 11 | First class brick work in foundation and plinth including cost of all materials as required complete: In cement mortar 1:6 ( 1 cement : 6 fine sand ) |
| 12 | Providing and fixing 1mm thick M.S. sheet door withframe of 40x40x6mm angle iron and 3mm M.S. gussetplates at the junctions and corners, & with cleats withbolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:-Using M.S. angels 40x40x6 mm for diagonal braces. |
| 13 | Providing wood work in frames of doors, windows,clerestory windows and other frames, wrought framedand fixed in position :Local Teak Wood |
| 14 | Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. all complete as per direction of Engineerin-charge.40mm thick. |
| 15 | Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge. 450 mm X 300 mm in all shades and design |
| 16 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 17 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.Urinal Pan |
| 18 | Boring with 100 mm diameter casing pipe for hand pump/ tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the hand pipe/tube well is lowered and tested : Beyond 12 m and upto 18 m depth |
| 19 | Providing and placing in position filters of 40 mm diameter G.I. pipe of medim class as per IS : 1239 with latest amendment with brass strainer of approved quality. |
| 20 | Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well. |
| 21 | Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories. |
| 22 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 23 | Providing and fixing plain bend of required degree.100 mmSand cast iron S&S as per IS - 1729 |
| 24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal outer dia .Pipes |
| 25 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. External work. 40 mm nominal outer dia .Pipes |
| 26 | Providing and fixing C.P. brass bib cock of approvedquality conforming to IS:8931.15 mm nominal bore |
| 27 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipe - 110 mm OD |
| 28 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of the Engineer in charge. |
| 29 | Finishing with epoxy paint ( one or more coats ) ofapproved brand and manufacture at all locationsprepared and applied as per manufacturer'sspecification on old work including preparation ofsurface etc. as required complete as per direction of the Engineer in charge:-On steel work. Please Enable Macros to View BoQ information |