| 1 | Total Hip replacement (THR) – All SizesUn cemented: -(Metal on Poly) All should be of Same MakeImplant Should be USFDA / INDIANFDA approved only |
| 2 | The femoral Stem should have morphometric wedge geometry and HA coating Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck length options, two offset options / Two Neck Angle minimum and made up of titanium material. |
| 3 | The acetabular shell made of Titanium Hemispherical should porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 38 to 64 mm with required cancellous bone screws. Can accomadate 22, 28, 32, 36, head |
| 4 | Insert should be Highly Cross linked polyethylene. The Polyethylene should have 0-20 degree or more posterior superior lip. The Polyethylene is compatible to accommodate 22mm/28mm, 32mm, and 36mm heads. |
| 5 | Femoral heads should be COCR with all sizes 22mm/ 28mm/32mm/36mm with minimum 4 variable necklength. |
| 6 | Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter. |
| 7 | Total Hip replacement (THR) – All SizesUn cemented: -(Ceramic on Poly)All should be of Same MakeImplant Should be USFDA / INDIANFDA approved only |
| 8 | The femoral Stem should have morphometric wedge geometry and HA coating . Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck length options, two offset options / two neck angle minimum and made up of Ti6Al4V material. |
| 9 | The acetabular shell made of Titanium Hemispherical should porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 38 to 64 mm with required cancellous bone screws. Can accomadate 22, 28, 32, 36, head |
| 10 | Insert should be Highly Cross linked polyethylene. The Polyethylene has 0-20 degree or more posterior superior lip. The Polyethylene is compatible to accommodate 22mm/28mm, 32mm, and 36mm heads. |
| 11 | Femoral heads should be Ceramic with all sizes 22mm/28mm/32mm/36mm with minimum 4 variable necklength. . |
| 12 | Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter. |
| 13 | Total Hip replacement (THR) – All SizesCemented: - With metal on poly. Note: - All should be of Same Make except cementImplant Should be USFDA / INDIANFDA approved only |
| 14 | Cemented femoral stem ss should Highly polished, Double tapered with collarless design. |
| 15 | The Cemented cup should have Ultra-High Molecular Weight Polyethylene with PMMA cement spacer easily identifiable the cup position on an X-ray. Cup Should be available in the I.D 22mm/28 /32 / 36 mm with OD 42 – 60 mm with two packets of bone cement. |
| 16 | Femoral heads should be COCR Metal Head with all sizes 22mm/28mm/32mm/36mm with minimum 4 variable necklength. |
| 17 | Total Knee replacement Cemented Oxidized Zircoinum Hi-flex – All Sizes Note: - All should be of Same Make except cementShould provide option both PS and CR knee in same implant Implant Should be USFDA / INDIANFDA approved only |
| 18 | femoral component should be availabe in have both PS/CR Option should have standard & narrow option ,Should have ability to accept Augments in Primary femur, should be made up of Oxidized Zirconium meterial,Primary femur should accept constrained insert also |
| 19 | Tibial component Should be Anatomical & made up of titanium alloy,Same tibia should accept all type of inserts PS/CR/ConstraintShould have highly polished surface |
| 20 | Polyethelene Should have PS/CR/Constraint Insert option both in PS/CR |
| 21 | Patella Should be Round Made up of UHMPWE Polyethelene Size should have 29-35mm |
| 22 | Bone Cement |
| 23 | Complex/ Revision hip replacement with all type & size of wedges & cages etc.THR.Note: - All should be of Same Make except cementImplant Should be USFDA / INDIANFDA approved only |
| 24 | The acetabular shell should porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 44 to 62 mm with required cancellous bone screws.The system should compose of a Liner and Poly Insert. The system should incorporate the following dual points of articulation- • 22.2mm or 28mm femoral Metal head.• Large polyethylene insert that mimics a femoral head |
| 25 | Dual Mobility Liner- • Dual Mobility Liner should be made of CoCr.• The system should have inner change locking mechanism and positive rotation tabs• The Liner should come with Removal Tool Slot.• The Liner should be available in all sizes- 36 to58 |
| 26 | Poly Insert- The insert should be made up of Highly Cross linked polyethylene which should be wear resistant |
| 27 | The femoral Stem should have morphometric wedge geometry and HA coating/ porous coating. Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck lengthoptions, two offset options minimum and made up of Ti6Al4V material. |
| 28 | Femoral heads should be COCR Metal with all sizes 22.2/ 28mm |
| 29 | Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter. |
| 30 | Total Knee replacement Cemented Gold TKR– All Sizes Note: - All should be of Same Make except cementShould provide option both PS and CR knee in same implant Implant Should be USFDA / INDIANFDA approved only |
| 31 | Gold (TiNbN coated) Femur with 7 radii design, with thin Anterior flange, Femur should have 6 degree deep trochlear groove with asymmetrical cam & Spine mechanism for rotation up to 15 degree. |
| 32 | Gold (TiNbN coated) Tibial Base Plate should have a 5 point locking mechanism, All Sizes |
| 33 | Ultra High Molecular weight Polyethylene liner with Vitamin-E. |
| 34 | Universal Patella |
| 35 | 40 gms Bone Cement |
| 36 | Complex/ Revision hip replacement with all type & size of wedges & cages etc.THR.Note: - All should be of Same Make except cementImplant Should be USFDA / INDIANFDA approved only |
| 37 | Revision uncemented stem should be long and length should be between 180 - 380 mm, Modular or distal fixing stem / Calcar replacing |
| 38 | Revision uncemented acetabular shell have multi hole with min. 8 holes and HA/ highly porous Coated. |
| 39 | Revision uncemented acetabular shell should provide dual mobility cup which composed of CoCr liner and highly crossed linked polyethylene which support 22- and 28-mm femoral metal head.(optional) |
| 40 | Acetabulum augments |
| 41 | Acetabulum mesh. |
| 42 | Acetabulum cages various sizes |
| 43 | Uncemented acetabular shell especially designed for protrusion which is peripherally locking. |
| 44 | Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter. |
| 45 | Revision cemented stem should long and the length would more than 200 mm, with bone cements. |
| 46 | The Cemented cup should have Ultra-High Molecular Weight Polyethylene with PMMA cementspacer easily identifiable the cup position on an X-ray. Cup Should be available in the I.D 28 /32 / 36mm with OD 46 – 60 mm. |
| 47 | The femoral Stem should have morphometric wedge geometry and HA coating/ porous coating. Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck lengthoptions, two offset options minimum and made up of Ti6Al4V material. |
| 48 | Femoral heads should be COCR Metal Head with all sizes 22mm/ 28mm/ 32mm/ 36mm. |
| 49 | Insert should be Highly Cross linked polyethylene. The Polyethylene has 10-degree or more posterior superior lip. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads. |
| 50 | Femoral heads should be Ceramic with all sizes 28mm/32mm/36mm.Note- Should provide quotation for individual components. |
| 51 | Total Knee replacement Cemented (TKR) Hi-flex – All Sizes Note: - All should be of Same Make except cementShould provide option both PS and CR knee in same implant Implant Should be USFDA / INDIANFDA approved only |
| 52 | Primary Cemented TKR- Femoral components COCR various sizes, Narrow & standard option with ability to accept both distal and Posterior augment, PS & CR TKR can be done with same instrument. Implants should have good survivourship rate |
| 53 | Tibial Baseplate various sizes, titanium, anatomical tibia base plate with ability to accept extension stem/ rod, Tiba can accommodate any size ( + 2) Femoral Component |
| 54 | highly crossed linked polyethylene various sizes, should have option for High fkex, constrained poly inn same poly both PS & CR |
| 55 | patellar component various sizes |
| 56 | Bone CementNote: - All should be of Same Make except cement |
| 57 | Unicondylar Knee replacement Fixed Bearing Unicondylar KneeNote: - All should be of Same Make except cement |
| 58 | Uni-condylar Knee Femoral Component Should be made up of Oxidized Zirconium Material,Should have Size 2-7 LM/RL, Should have same Lug preparation from Size 3-7, |
| 59 | Uni-condylar Knee tibial Component Should be made up of titanium Alloy |
| 60 | Inserrt Should be Madeup of Highly crosslinked P{olyethelyne material Size should be 8,9,10,11mm |
| 61 | Bone Cement |
| 62 | Mobile Bearing Unicondylar KneeNote: - All should be of Same Make except cement |
| 63 | Uni-condylar Knee Femoral Component Should be made up of Cocr Material,Should have Size 2-7 LM/RL, Should have same Lug preparation from Size 3-7, |
| 64 | Uni-condylar Knee tibial Component Should be made up of Cocr |
| 65 | Inserrt Should be Madeup of Highly crosslinked P{olyethelyne material Size should be 8,9,10,11mm |
| 66 | Bone Cement antibiotic/ normal |
| 67 | Revision Knee replacement all size and stems and wedgesSemi constraint TKR should have following componentsNote: - All should be of Same Make except cementImplant Should be USFDA approved only |
| 68 | Femoral component compatible with stem extension. |
| 69 | Tibial Baseplate compatible to stem extension. |
| 70 | Semi constrained polyethylene. |
| 71 | Distal Augments. |
| 72 | Posterior Augments |
| 73 | Offset |
| 74 | Tibial wedges various options |
| 75 | Patellar component |
| 76 | Fluted Stem |
| 77 | Bone Cement |
| 78 | Revision knee replacement all size and stems and wedgesHinge TKR should have following componentsNote: - All should be of Same Make except cementImplant Should be USFDA / INDIANFDA approved only |
| 79 | Femoral component compatible with stem extension. |
| 80 | Tibial Baseplate compatible to stem extension. |
| 81 | constrained polyethylene. |
| 82 | Distal Augments. |
| 83 | Posterior Augments |
| 84 | Offset |
| 85 | Tibial wedges various options |
| 86 | Patellar component |
| 87 | Fluted Stem |
| 88 | Bone Cement |
| 89 | Sleeve Tibia/Femur sleeve |
| 90 | Tibia femur cone |
| 91 | HEMI Shoulder replacement implants – all sizes including fracture stemAll should be of Same MakeNote - Note Should provide quotation for individual components |
| 92 | Fracture Stem Reverse Morse Taper provides the ability to move between a hemi, total, or reverse shoulder arthroplasty without removing a well-fixed Comprehensive Fracture Stem Anatomic 45 degree neck angle provides ample room under the collar for tuberosity reconstruction Contoured suture holes provide for significant reduction in suture wear. Six diameters available: 4, 6, 8, 10, 12, and 14mm Designed for cemented or uncemented applications |
| 93 | Humeral Head - Different variable sizes available in 38mm, 42mm, and 46mm |
| 94 | Taper Adaptor |
| 95 | Total Knee replacement Cemented (TKR) Hi-flex – All Sizes Note: - All should be of Same Make except cementShould provide option both PS and CR knee in same implant Implant Should be USFDA / INDIANFDA approved only |
| 96 | Primary Cemented TKR- Femoral components COCR various sizes, Narrow & standard option with ability to accept both distal and Posterior augment, PS & CR TKR can be done with same instrument. Implants should have good survivourship rate |
| 97 | Tibial Baseplate various sizes, titanium, anatomical tibia base plate with ability to accept extension stem/ rod, Tiba can accommodate any size ( + 2) Femoral Component |
| 98 | highly crossed linked polyethylene various sizes, should have option for High fkex, constrained poly inn same poly both PS & CR |
| 99 | patellar component various sizes |
| 100 | Bone CementNote: - All should be of Same Make except cement Please Enable Macros to View BoQ information |