| 1 | Dismantling R.C. floor, roof, beams etc.including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. In ground floor including roof. |
| 2 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm. |
| 3 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)---(a) With earth obtained from excavation of foundation. |
| 4 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating the same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made in measurement of finished quantity.) |
| 5 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 6 | Cement concrete with graded stone ballast (40 mm size excluding shuttering). In ground floor and foundation.(A) Pakur Variety. 1:3:6 proportion. |
| 7 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).--- a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.In i) Gr. floor. |
| 8 | (b) 25 mm to 30 mm shuttering without staging in foundation etc. |
| 9 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bennding to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.i) JSW /JSPL /SHYAM /SRMB /BMASL/ ELECTROSTEEL/SSL(a) In Ground Floor and Foundation. |
| 10 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm.nominalsize) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.--a) Pakur Variety. |
| 11 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips(20 mm.nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. (i) Pakur Variety.( I ) In Ground Floor & Foundation. |
| 12 | A) Brick work with 1st. Class bricks in C.M. ( 1: 6) (a) In foundation and plinth |
| 13 | (b) In superstructure, ground floor |
| 14 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. ( a ) Gr. Floor. |
| 15 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Exxcluding cost of chipping over concrete surface(b)20 mm. thick plaster. In ground floor. |
| 16 | (b) 15 mm. thick plaster. In ground floor. |
| 17 | (ii) With 1:4 cement mortar. (a) 10 mm. thick plaster In ground floor. |
| 18 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE: Cement 0.152 cu. M. per sq.m. |
| 19 | Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required.The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.--- a) Normal Acrylic Emulsion .(Two Coat).i) In ground floor. |
| 20 | Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior Immersion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C (One coat on new surface.)----- a) In ground floor. |
| 21 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper / acrylic emulsion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of E.I.C One coat. i) Water based interior grade acrylic primer. |
| 22 | Applying Acrylic emulsion paint of approved make and brand on walls and ceiling including sand papering in intermidiate course including putty (two coats). Standard Quality. |
| 23 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 24 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary(b) On steel or other metal surface : : With other than (hi-gloss) -(iv) Two coats (with any shade except white) |
| 25 | Priming one coat on timber or plastered or surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. (This item is applicable to new work or old work when the original..removal of old paint.) |
| 26 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (a) On timber or plastered surface : With other than (hi-gloss) -(iv) Two coats (with any shade except white) |
| 27 | M.S. structural works in columns, beams etc. with simple rolledstructural members (e.g. joists, angle, channel sections conformingto IS: 226, IS: 808 & SP (6)- 1964 connected to one another withbracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length,fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.-----I) For structural members of specified sections weighing less than 22.5 Kg./m |
| 28 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer. 1000 litre capacity |
| 29 | Labour for hoisting Plastic water storage tank. Up to 1500 litre capacity. |
| 30 | Labour for punching hole in plastic water storage tank up to 50 mm dia. |
| 31 | Supplying fitting & fixing UPVC Pipes A type and fitttings conforming to IS 13592-1992 with all necessary clamps, nails including making holes in walls, floors etc cutting trenches in any soil through masonary concrete structures etc, if necessary, and mending good damages including joining with jointing materials.(for rain water draining) A.) UPVC Pipes of 110 mm dia. |
| 32 | B) Plain Tee (UPVC), 110mm dia. |
| 33 | C) UPVC Shoe, 110mm dia. |
| 34 | D) Bend 87.5 degree of 110mm dia. |
| 35 | Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of CI brackets. (ii) 530 mm. X 430 mm. X 180 mm. |
| 36 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(i) 750 mm long |
| 37 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white.. C.P. nut, 15 mm dia.(i) 450 mm long |
| 38 | PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm |
| 39 | Supplying, fitting and fixing pillar cock of approved make. b) PTMT Pillar Cock - 15 mm. (Prayag or equivalent). |
| 40 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm. thick with silvering as per I.S.I specifications supported on fiber glass frame of any colour, frame size 550mm x 400mm. |
| 41 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (d) Sal : Local. |
| 42 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (iv) 25mm thick shutters with 12mm thick panel of size 30 to 45 cm. |
| 43 | Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction of Engineer-in-Charge.(a) 250 mm long |
| 44 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(c) 300mm long. |
| 45 | Supplying 125 mm. Dia. Acrylic handle for aluminium door as per approved make and brand. (a) natural colour. |
| 46 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(vi) 100mm. X 50mm. X 1.25mm. |
| 47 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) |
| 48 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.--Flash butt welded windows and ventilators--(no shop priming will be allowed to facilitate inspection of workmanship) Without integrated grills i) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bar (A) In Ground floor |
| 49 | ii) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. |
| 50 | iv) Two point nose steel handle including fitting and fixing. |
| 51 | vi) steel peg stay 300 mm long including fitting and fixing. |
| 52 | Supplying best Indian sheet glass panes set in .. with nails and putty complete. (In all floors for internal wall.. for external wall).(i) 4 mm thick (weighing 7.4 kg/Sq.m) |
| 53 | Supplying, fitting and fixing cast iron heavy type spiral staircase of approved design with 50 mm.dia. Stem and C.I. Steps 150 mm as per design 900 mm. high C.I, railing including necessary M.S. tie of suitable section embedded to wall with cement concrete (1:2:4) including cost of intermediate C.I. platform secured with necessary tie to stem and wall with cement concrete (1:2:4) including fixing the stem in ground with cement concrete (1:3:6) complete in all respect with all labour and materials. (Payment to be made on vertical height in between 1st step and topplatform.)(a) With 1200 mm.dia. well |
| 54 | Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc.) |
| 55 | Supplying, fitting, fixing, Chain link fencing of approved quality with R.C.C posts wooden posts or iron posts by means of galvanised \\"C\\" clips to grid of horizontal strands of galvanised high tensile spring steel wire of 12 S.W.G which have to be tensioned and fixed to the vertical posts by means of galvanised special clips, bolts and nuts etc.(The rate is exclusive of the cost of posts)(I) 25 mm. x 25 mm. x 12 g. |
| 56 | Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor |
| 57 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket reducing tee, short piece etc. fitted with holder bats clamps, including, cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) PVC Pipes(Dia)( I )20 mm Dia |
| 58 | 25 mm Dia |
| 59 | 32 mm Dia |
| 60 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only)a) 32 mm. dia. |
| 61 | b) 25 mm. dia. |
| 62 | SupplyofPVCpipes&fittings Schedule80 (mediumduty) conforming to ASTMD-1785 and threaded to match with GI Pipes asperIS:1239 (Part - I) ( a ) 150 mm dia ( Medium duty) |
| 63 | ( b ) 80 mm dia ( Medium duty) |
| 64 | Labour for boring tube well of required dia by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting, fixing same complete including bucket washing and other incidental works in connection.The tube well should have a minimum 50mm. gap in between the outside of the tube well pipe and the bore. For depth upto 150 metre for 80 mm dia. tube well with top enlargement of 150 mm dia .i) 80mm dia Boring |
| 65 | i) 150mm dia Boring |
| 66 | Supplying Hi density Polythene strainer of approved make with adapter conforming to I.S. specification 80mm dia. |
| 67 | Supplying, fitting and fixing heavy type bell mouth reducing socket.(ii) 75 mm X 150 mm |
| 68 | Supplying , fitting & fixing 300 mm. M.S. housing clamp of approved quality |
| 69 | Supplying, fitting and fixing steel cutter piece upto 450 mm. long with socket ( i ) 75 mm |
| 70 | Supplying, fitting and fixing G.I. cap at top i)(ii) 150 mm |
| 71 | Packing the annular space between the outside of the tube-well pipes and strainers and the bore with pea size washed gravel of approved quality having the size from 2mm to 5 mm or the size approve by the Engineer – In – Charge including cost of all materials, labour and equipment complete |
| 72 | Washing and developing tube well with air compressor pump and engine for 8(wight) hours continuous pumping per day with necessary arrangement for testing the yield in gallons per hour with ‘V’ notch including hire and labour charges for all tools and plants and scaffolding as required complete |
| 73 | Supplying fitting and fixing S.R. 100 mm. CRI Submersible pump 1 H.P., 14 Stage including submersible cable and Control Panel Board by lowering it into the tube well through lowering pipe at design depth and anchoring for pump vertical, with installation of electrical wire to be required for connecting pump with appliance and to make the pump serviceable by giving demostration with trial run of pump etc. all complete as per direction of Engineer-in-charge. |
| 74 | Supplying, fitting and fixing check valve G.M. tested to 21 kg per sq. cm. i) 32mm Please Enable Macros to View BoQ information |