| 1 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications Overall size 300sq.mm (3½ Core) Armoured (Underground) 34.10AXXXI (1340 .00 + 95% = 2613.00 + 5.35% = 2752.79) |
| 2 | Overall size 185sq.mm (3½ Core) Armoured (Underground) 34.10A XXIX (973+70% = 1654.1 + 5.35% = 1742.59) |
| 3 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General specifications:- Overall size 300sq.mm (3½ Core) Armoured (Loose) 34.10B XXXI (1045+95% = 2037.75 + 5.35% = 2146.76) |
| 4 | Overall size 185sq.mm (3½ Core) Armoured (Loose) 34.10B XXIX (680+95%= 1326 +5.35%= 1396.95) |
| 5 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- MCCB Four Pole 630 amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 34.23 B IX (26020.00 + 50% = Rs. 39030.00 +5.35% = Rs. 41118.10) |
| 6 | Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-MS Sheet Enclosure having provision for MCCB 200- 630Amp.with extended rotary handle (Approx. Size 750mm x 300mm x 50mm) 34.23DIb (4218.00 + 40% = 5905.2 + 5.35% = 6221.13) |
| 7 | Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method.Including excavation , stringing and jointing of pipe upto 160mm complete 28.71 (850.46 + 5.35% = Rs. 895.96) |
| 8 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely Aluminium thimble cable core size 185 sq.mm 34.38 A (ix) (62.00 +5.35% = Rs. 65.31) |
| 9 | Aluminium thimble cable core size 300 sq.mm 34.38 A (Xi) (116.00 +5.35% = Rs. 122.20) |
| 10 | Supply Erection of 400 Amp 4 Pole power contactor MCX 43 2 No. + 2NC cat. no. CS97025 make Lauritz Knudsen including patty materials complete in all respect as and desired by the Engineer in charge at site. |
| 11 | Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications On Load Change Over Switch Four Pole 320amp., 415volts (With Sheet Enclosure) 34.22B VII (14920+40% = 20888+5.35% = 22005.508) |
| 12 | SURFACE HGW CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES Supply & erection of Wiring fan point (With-out fan box) 34.07 (i) (1066.00 + 25% =Rs. 1332.50 + 5.35% = Rs. 1403.78) |
| 13 | Supply & erection of wiring light point 34.07 ii (761.00 + 25% = Rs. 951.25 + 5.35% = Rs.1002.14 |
| 14 | Wiring 6Amp. Plug control comprising point 34.07 (V) (318.00 + 25% = Rs. 397.50 + 5.35% = Rs.418.76) |
| 15 | Supply & erection of wiring 16Amp. Plug control comprising wall socket point 34.07 (VI) (359.00 + 25% =Rs. 448.75 +5.35% = Rs.472.76) |
| 16 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 1.5 sq.mm (Un-sheathed) 34.09 ii (18 + 60 % = Rs. 28.80 +5.35% = Rs.30.34 ) |
| 17 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 4 sq.mm (Un-sheathed) 34.09 iv (39 + 60 % = Rs. 62.40 +5.35% = Rs. 65.73 ) |
| 18 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) 34.12 ii (39.00 + 40% = Rs. 54.60 + 5.35% = Rs.57.52) |
| 19 | MCB Double Pole 6-32amp. (10kA, CurveC) 34.16A VI = Rs. 408+50% = 612.00 +5.35% = Rs. 644.74 ) |
| 20 | Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-SP&N Double Door Distribution Board 8 way each 34.17 (ii) = Rs. 1169+15% = Rs. 1344.35+5.35% = Rs. 1416.27) |
| 21 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs MCB Single Pole 6-32amp. (10kA, Curve-C) 34.16 A ii (134.00 + 50 % = Rs. 201+ 5.35 % = Rs. 211.75 )) |
| 22 | Supply and erection of High quality aluminium extruded with decorative end caps glazed LED batten of Make Jaquar Item Code LGLZ01x020XC or Its equilant Make and Cat. of Philips / Crompton including erection of the same with connections, testing etc.complete in all respects as approved and desired by the Engineer in-charge at site. (BFUHS/UWD/2019/10622 Dt 27/5/2019) |
| 23 | Supply and erection of Ceiling Fan 1200mm (48\\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High Speed Opel White, Havell's Velocity HS, Bajaj, Orient |
| 24 | Supply and erection of Heavy duty Exhaust Fans 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make: Crompton EXHD300-6-1, Havells Turbo Force SP, Anchor Anmol Heavy Duty BFUHS/UWD/2021/25524-30 Dt 20/12/2021 Please Enable Macros to View BoQ information |