| 1 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes Cement mortar 1:4 (1 cement : 4 coarse sand) DAR.No-6.4.1, |
| 2 | Dismantling tiles work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25mm. DAR 15.23.1 |
| 3 | Providing and laying rectified Glazed ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622 of approved make in colours White, lovry Grey Fume Red Brown laid on 20 mm thick cement mortar 1:4 (1 cement :4 Coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc complete. 11.39 |
| 4 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) of approved make in all colours shades except burgundy bottle green black of any size as approved by E/I in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed pigment of matching shade complete. 8.31 |
| 5 | Providing and fixing C.P. brass long nose bib cock of approved quality confirming to IS standard and weighting npt less than 810 gms.15 mm nominal bore.18.50.1. |
| 6 | P/F C.P. brass Angle Valve for basin mixture and geyser points ofapproved quality confirming to IS:8931.15 mm nominal bore.18.53.1. |
| 7 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter DSR 12.41.2 |
| 8 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm DSR 12.42.1.2 |
| 9 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend DSR 12.42.5.2 |
| 10 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm DSR 12.43.2 |
| 11 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes DSR 18.8.1 |
| 12 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan..17.15. |
| 13 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 100 mm diameter.18.22.1. |
| 14 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity-white.17.18.1. |
| 15 | P/F Wash Basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern white vitrous china wash basin size 630x450 mm with a pair of 15 mm cp brass piller taps.17.7.1. |
| 16 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia DAR 17.22b |
| 17 | Structual Steel work riveted bolted or welded in built up section, trusses, Builds up gates, framed work lncluding cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Sl.N0-10.2, |
| 18 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DAR 9.21.1 |
| 19 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters With ISI marked stainless steel butt hinges of required size Second class teak wood DSR 9.27.1.21 |
| 20 | 12 mm thick Cement Plaster with Cement mortar in proportion of mix 1:4 (1 cement : 4 coarse sand). DAR-13.4.1 |
| 21 | P/A white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.80 |
| 22 | Finishing wall with Premium Acrylic Smooth exterior Paint with Silicone Additives of required Shade New work. (Two or More Coats applied @1.43 ltr/10 sqm) Over and Including Priming Coat of Exterior Primer applied @ 2.20kg /10 sqm) (Apex Ultima, Weather Coat All guard asian, Berger. (Ch-15/DSR N0-13.47.1 ) |
| 23 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick corrugated (2.5” or 4.2” or 6”) or step down (2” or 3” or 6” ) as specified . DSR 12.47.1 Please Enable Macros to View BoQ information |