| 1 | Earth work in Surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan lncluding getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (All kinds of soil)( DSR.No-2.1.1, |
| 2 | Providing and laying in Position Cement Concrete of Specified Grade excluding the cost of Centering and shuttering all work up to plinth level 1:5:10 (1 cement, 5 Coarse sand (Zone-lll) 10 graded Stone 40 mm nomical size Derived from natural Sources ) DSR N0-4.1.10, |
| 3 | Brick work with Common burnt clay F.P.S.(non modular ) bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:4 (1 cement : 4 coarse sand) including Supply of all materials labour T&P etc. required for proper completion of work as per DSR.No-6.1.1, |
| 4 | Steel reinforcement for R.C.C. work including Straightening, Cutting, Bending, Placing in position and binding all Complete upto Plinth Level. Themo-Mechanicaily Trated Bars of grade Fe-500D or more. DSR-5.22C.1, |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement Mortar 1:4 (1 cement : 4 coarse sand) including Supply of all materials labour T&P etc. required for proper completion of work as per DSR.No-6.4.1, |
| 6 | Providing and laying Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved Make, in all colours & shades, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing with grey Cement Slurry @ 3.3 kg/Sqm including grouting the joint with white cement and matching Pigments etc. Complete. Size of Tile 600x600 mm. (DSR-11.41.2) |
| 7 | Providing & Fixing UV Stabilised Fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8 mm dia, G.l. plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovings incorporating minimum 0.3%, ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air Pockets and shall Conform to IS 10192 and IS 12866. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5'' or 4.2'' or 6'') or step-down (2'' or 3'' or 6'' ) as Specified. DSR No. 12.47.1, |
| 8 | Providing Corrugated G.S. Sheet roofing including Vertical /Curved Surface Fixed with polymer Coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers filled with white Lead, including a Coat of approved Steel Primer and Two coats of approved Paint on Overlapping of Sheets Complete (UP to any Pitch in horizontal /Vertical or Curved Surface), excluding the Cost of Purlins, rafters and and trusses and including cutting to size and shape wherever required. (1.00 mm thick with Zinc Coating not less than 275 gm/m²) DSR N0-12.1.1, |
| 9 | Structual Steel work riveted bolted or welded in built up section, trusses, Builds up gates, framed work lncluding cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR N0-10.2, |
| 10 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). DSR No. 21.18, |
| 11 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/aqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a derection perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every juction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compoung, jointing tapes, finishing with jointing compound in 3 layers covers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board, DSR No. 12.45.3, |
| 12 | Dismantling old Plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dummping ground within 50 metres lead. DSR No.-15.56, |
| 13 | 12 mm. Thick plaster with cement mortar in proportion of 1:4 cement & coarse sand DSR No- 13.4.1, |
| 14 | Removing white or colour wash by scrapping andsand papering and preparing the surface smooth including necessary repairs to scratches etc. complete DSR N0 13.88, |
| 15 | Providing and Applying white Cement based Putty of average thickness 1 mm. of approved brand and manufacture. Over the Plastered wall Surface to Prepare the Surface even and Smooth Complete. DSR N0-13.80 |
| 16 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work (Two or more coats applied @1.43 ltr/10sqm) over existing cement paint surface (apex Ultima, weather coat All guard). (DSR N0. 13.112.1) |
| 17 | Painting with synthetic enamal paint of approved brand and manufactorar of required colour to give an evan shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR No. 13.62.1, |
| 18 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. DSR No-15.60 Please Enable Macros to View BoQ information |