| 1 | Dismentling steel tubular poles in C.C. foundation including excavation, filling of holes, restoring surface, loading at site and delevering, unloading , sorting, stacking properly at any place as per direction upto a lead of 1.6 K.M. |
| 2 | Removing of luminaries with lamp from the pole/ column/High Mast and keeping them ready for dispatch as per direction of EIC. HPMV/HPSV/MH/LED Street light fittings on Steel tubular poles and High Masts. |
| 3 | Supplying of swaged steel tubular pole as per IS 2713, Pt-II 1980 for following designation and dimensions.410 SP-53, 11.0 Mtr, 183.00 kg. |
| 4 | Erection of single steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (proportion and dimension indicated below), having 600 x 600 x 150mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 Mts. dia and 0.30 Mts. above ground level including 3mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6km from store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.a) Above 9.0 mtr. size: 0.6x0.6x1.91 mts. |
| 5 | Supply and fixing of M.S. sole plate (450mm x 450mm x 6mm) at the buttom of the pole. |
| 6 | Supply & fixing double arm projected lamp bracket (single pipe bending) of 50mm dia M.S. pipe of 2.5 Mtr. long each having 105 degree curvature with reducing socket to the fitted at the top of the pole with bolts, nuts, clamps etc. as required and painting the set with paints. |
| 7 | Supply & fixing M.S. loop box (10 SWG) of size 269 x 219 x 125mm having almirah type cover complete with special type locking arrangement including supply & fixing 200mm x 150mm x 6mm backlite sheet 1 No. 4-way ebonite connector block. 1 No. 15 Amp fuse unit (BPC/Juvas/ Havells make) fitted inside the box and suitable size danger board riveted on cover of the box outside & fixing the box with pole by means of M.S.Clamps of 25mm x 6mm of suitable length and encasing the box by 1:2:4 cement concrete with graded stone chip (19mm down). The depth of the concrete should be 60cm x 45cm x 45cm including Plastering and neat cementing and supply & fixing 2Nos compression gland of suitable size and making all necessary connection as required. |
| 8 | Painting of steel tubular pole of lengths and no. of cables of paint, as given below with ready mixed paint/primer of approved make, and brand including preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint upto 9.0 Mtr. long Polei) One coat of red lead/Zinc chromate priming |
| 9 | ii) 1st Coat of synthetic enamel paint over the primer. |
| 10 | iii) 2nd coat of synthetic enamel paint over the 1st coat. |
| 11 | Painting Block letters or digits within a circle/square as required, with \\"Black Japan\\" paint of approved make & brand, the size of letters and digits as given below.a) Size 50mm and upto 75mm |
| 12 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm diax 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a) By ISI-Medium GI pipe |
| 13 | Excavation of soil for installation of Earth Electrode and filling & ramming.(a) For Soft Soil |
| 14 | Supplying and fixing 240/415V MCB of Breaking Capacity 10KA & C characteristics on din rail of existing DBs and necessary connection.A) 10A (SP).Make: legrand/seimens/Schneider |
| 15 | Hoisting, fixing and commissioning of luminaries including making necessary connection and earthing attachement. HPSV/HPMV/LED fittings of any wattage. |
| 16 | Supplying of 1.1KV grade PVC insulated armoured Aluminium conductor of Size: 16 Sqmm, 4 Core (Make: Polycab/Gloster/Havells). |
| 17 | Laying of one No. cable upto 35 Sqmm. In underground trench 460mm wide x 760mm average depth. With brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, levelling up and restoring surface duly rammed. |
| 18 | Laying only one cable upto 50 Sqmm. Through existing RCC/Hume/GI Pipe/open masonary trench for 4-core. |
| 19 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring or dust & moisture-proof entry of XLPE/PVC armoured cables.Size: 16 sqmm, 4 core. |
| 20 | Finishing the end of following XLPE/PVC armoured cables by crimping method including supplying and fixing solderless socket (Dowels make), taps, anticorrosive paste & jointing materilas.i) 4 core, 16 Sqmm. |
| 21 | Supply & fixing of 50mm dia heavy gauge Polythene pipe (2mm thick) for protecting U.G. cable. |
| 22 | Supplying and fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required of size 40mm dia. |
| 23 | Supplying and drawing 1.1KV Single Core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required from terminal box at Bottom end to the respective LED fittings.1.a) 3 x 22/0.3(1.5 sqmm.) |
| 24 | Finishing of the preinsulated wire ends by socketing with pin/ring type coper sockets and insulated tapes etc. including supplying sockets tapes of size 2.5 sqmm.(i) 2.5 sqmm |
| 25 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 26 | Micro tunneling arrangement and laying of 65mm dia 5mm thick HD PVC pipe through earth below 1m ground level complete with arrangement of machinery pipe etc. |
| 27 | Add GST@18% on Sl. No. 1 to 26 |
| 28 | Add labour cess @1% on Sl. No. 1 to 27 Please Enable Macros to View BoQ information |