| 1 | Charges for Repair & maintenance, Proper Watch&ward of entire electrical system with 3245 Nos. LED/decorative/Flood light,11 Nos. High Mast, 412 Nos.Try Colour Tiranga Strips,2 Nos.125 KVA DG Set operation& all other installed accessories in Sector-2,3,4,5,6,7,8,9,10,11,12,14,15,16,17,18,CC Roads & Pusta Road material like Octogonal Poles,ST poles,Diffrents size of Transformers,HT/LT cables,ACSR Insulated weasel conductor,Diffrent size of TPN panels,400 Amp.&63 Amp. Onload Changeover switch& all other available material in above sectors/area,s as per direction of Engineer-in charge. including with dismantling & re-fixing of all street light at above Sector/Areas during the period of AMC for (12 Months) (With manpower- 05 Electrician,6 Helper) (capable for work on 11 K.V HT Line) |
| 2 | Cost of all material,spares wire fuses,small accessories required for general maint.,cleaning, oiling/gressing etc. to keep the entire installation of street lighting & High Mast towers in perfect working condition during Annual Maintenance Contract period.for (36 Months) (L.S. Basis) as per direction of Engineer-in charge |
| 3 | S/F of 6 Amp.To 32 Amp. SP MCB (10KA) C curve Cat-B as per UPPWD Sch. No. 1002 |
| 4 | S/F of heavy duty cadmium plated copper connector with end plate complete in all respects (c) four way connector HKM 100 as per UPPWD Sch. No.1128 |
| 5 | Supply & wiring of submain with 2 Nos.of 2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P reuired for proper completion of the work as directed as site by Engineer I/C as per UPPWD Sch. No.289 |
| 6 | Supply & laying 16 sq mm 4 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V grade in existing HDPE/GI pipe & Surface laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(i) & 507 (Polycab/Havells/ Grandlay/Gloster Make) |
| 7 | Supply & laying 10 sq mm2 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V grade in existing HDPE/GI pipe & Surface laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(b) & 507 (Polycab/Havells/ Grandlay/Gloster Make) |
| 8 | Supply & laying 25 sq mm 3.5 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V grade in existing HDPE/GI pipe &Surface laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(j) & 507 (Polycab/Havells/ Grandlay/Gloster Make) |
| 9 | S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer - incharge as per UPPWD sch. no. 503 (i) 16 sq. mm 4 core |
| 10 | S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer-incharge as per UPPWD sch. no. 503 (k) 25 sq. mm 3.5 core |
| 11 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (d) 16 sq. mm |
| 12 | S/F ofpalm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (f) 25 sq. mm |
| 13 | Supply & Laying of 63 mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend,couple etc. confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete in all respect. |
| 14 | Supply & Laying of 63 mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend,couple etc. confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. througth horizontal boring trenchless (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete in all respect |
| 15 | Painting letters (Pole no.) 2.5 cm upto 8.0 cm size complete on street light pole/panel/other electrical properties under UPSIDA including cost of all material men and T&P complete in all respect |
| 16 | Painting of ST/Octogonal pole/High Mast foundation excavation below upto Ground level,Surface finishing and painting with white cement and dark yellow colour paint with double coat including cost of all material men and T&P complete in all respect |
| 17 | Lowring of 30/16 Mtr. High mast lighting system complete in T&P men & material required proper completion of work as per direction of Engineer-in charge |
| 18 | S/F of S.S. wire rope set Suitable for 30/16 Mtr. High Mast lighting system as per specification complete including all T&P men and material required for proper completion of work as per direction of Engineer-in charge |
| 19 | S/F of Trailing Cable Suitable for 30/16 Mtr. High Mast lighting system as per specification complete including all T&P men and material required for proper completion of work as per direction of Engineer-in charge |
| 20 | S/Oiling of winch machine for High Mast lighting system complete including all T&P men and material required for proper completion of work as per direction of Engineer-in charge |
| 21 | S/F of ML-4 contactor MDS/L&T make complete including all T&P man and material required for proper completion of work as per direction of Engineer-in charge |
| 22 | S/F of mounting time switch (timer clock) L&T/MDS make complete including all T&P men and material required for proper completion of work as per direction of Engineer-in charge |
| 23 | Supply & fixing of driver suitable for 65 to 120 watt LED street light/ 50 to 200 Watt LED Flood lights as per same make that’s are installed at Site complete in all respect |
| 24 | Supply & fixing of MCPCB with LED & Lance suitable for 65 to120 watt LED street light/ 50 to 200 Watt LED Flood lights as per same make that’s are installed at Site complete in all respect |
| 25 | Supply & Fixing of Glass suitable for 65 to120 watt LED street light/ 50 to 200 Watt LED Flood lights as per same make that’s are installed at Site complete in all respect |
| 26 | Supply & fixing of LDR suitable for 65 to120 watt LED street light/ 50 to 200 Watt LED Flood lights as per same make that’s are installed at Site complete in all respect |
| 27 | Supply & fixing of special protection device (SPD) suitable for 65 to120 watt LED street light/ 50 to 200 Watt LED Flood lights as per same make that’s are installed at Site complete in all respect |
| 28 | Repair of 25/63/250 KVA Transformer including changing of HV & LV Coil ,Bushing,Gasket & Fresh Transformer oil without returning of old oil & unservicable material complete in all respects as per direction of E/I |
| 29 | Dis./Re-errection & Cartage charges of 25/63/250 KVA Cu/Al. wound outdoor type Transformer from site to workshop & workshop to site respectively as per ISS including all type of fees complete in all respects as per direction of E/I |
| 30 | Hiring Charges of 80-100 Feet expandable street light repairing hydraulic lift capacity 300 Kg. including cost of operator,mounting vehicle and with fuel etc. for 6 days in a month on hourly basis or as per actual requirement for Octogonal,ST street light poles complete in all respects as per direction of E/I (Total Hours=6 days in month*8 hour per day*12 Month in a year = 576 Hour) |
| 31 | Hiring charges of fault locating machine (for High-pressur test) of 11 KV H.T Under ground cable fault including exacavation & restoration at fault location complete in all respects as per direction of E/I . |
| 32 | S/F of Outdoor type 11 KV jointing kit heat shrinkable type suitable for XLPE 70 Sq.mm 3 core 11 KV HT cable including all materials, labour and T&P required for proper completion of work fault including exacavation & restoration at fault location complete in all respects as per direction of E/I (Raychem,Densons, Birla,3M make) |
| 33 | S/F of 11 KV straight through jointing kit heat suitable for XLPE 70 Sq.mm 3 core 11 KV HT cable including all materials, labour and T&P required for proper completion of work fault including exacavation & restoration at fault location complete in all respects as per direction of E/I (Raychem,Densons, Birla,3M make) |
| 34 | Supply and making straight through joint with cast resin compound including ferrules and other joints materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor 16 sq.mm 2 core cable of 1100 v grade complete rates as per DSR no. 9.3.1 |
| 35 | Supply and making straight through joint with cast resin compound including ferrules and other joints materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor 16 sq.mm 4 core cable of 1100 v grade complete rates as per DSR no. 9.3.29 |
| 36 | Supply and making straight through joint with cast resin compound including ferrules and other joints materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor 25 sq.mm 2 core cable of 1100 v grade complete rates as per DSR no. 9.3.2 |
| 37 | Supply and making straight through joint with cast resin compound including ferrules and other joints materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor 25 sq.mm 3.5 core cable of 1100 v grade complete rates as per DSR no. 9.3.17 |
| 38 | Supply and making straight through joint with cast resin compound including ferrules and other joints materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor 35 sq.mm 3.5 core cable of 1100 v grade complete rates as per DSR no. 9.3.18 |
| 39 | Supply and making straight through joint with cast resin compound including ferrules and other joints materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor 70 sq.mm 3.5 core cable of 1100 v grade complete rates as per DSR no. 9.3.20 |
| 40 | Supply and making straight through joint with cast resin compound including ferrules and other joints materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor 120 sq.mm 3.5 core cable of 1100 v grade complete rates as per DSR no. 9.3.20 Please Enable Macros to View BoQ information |