| 1 | Supplying, Installation, Testing and Commissioning of 200mm Dia Pulp Valve CI Body in the existing Line including cutting/ modification of line for fitting the valve complete etc. as required. |
| 2 | Supplying, Installation, Testing and Commissioning of fixing of following dia. Gun metal Horizontal Non Return valve (screwed type) on the existing pipeline, including testing & Commissioning etc. complete including dismantling of existing valve as required. 50mm Dia |
| 3 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete including dismantling of existing pipe as required. 50mm Dia |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth. Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 6 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work;using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M20 grade with minimum cement content of 270 kg /cum |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns |
| 8 | Cement Plaster (In Coarse Sand) 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand) |
| 9 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450 mm internal dimensions |
| 10 | Cleaning of Aeration Tank , including removal of sludge and debris with Sucker machine / manpower and disposition of waste complete as required |
| 11 | Less Credit for Buyback of Old Material |
| 12 | Rusted/Damaged GI Pipe |
| 13 | Rusted/Damaged Non Return Valves Please Enable Macros to View BoQ information |