| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: Executive Engineer(E) PWD M-253 Name of Work:- RMO of electrical and mechanical installations on PWD roads in East Delhi under EMD M-253, Delhi (SH: Replacement of wornout / damaged street light Octagonal poles and LED luminaries , feeder pillar, cable & other associated work in Laxmi Nagar & adjoining area under Subdivision M-2532) NIT No.:119/EE(E)/PWD M-253/2025-26 Estimated Cost:-47,90,043/- Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Sub Head Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Fabrication , Supply and erection of flange mounted hot dip Galvanized Octagonal Poles of 10 Mtr. Height made from 3 mm thick HT Steel plate, having bottom dia of 175 mm. & top dia of 70 mm with base plate of size 275mm x 275mm x 16mm thick complete with connection window having flash cover with round sleeve at an aprox. height of 2 mtrs from the base for cable termination etc. on the existing cement concrete pedestal as required i/c supplying and fixing of the following accesories in connection window for cable termination i/c credit / buyback for old dismantled material i/c dismantling as on where it is basis etc complete as required : -a) 6 mm thick laminated / backalite sheet of suitable size- 1 Nob) 63 Amp 4 Way termination block- 1 No.c) 6 Amp 10 KA, SPMCB,'C' Characteristics Curve - 1 No |
| 3 | Providing and laying in position M-20 (1:2:4) reinforced cement concrete foundation of size 650 mm (L) x 650 mm (W) and 1600 mm (D) i/c excavation of earth, providing cutting, bending and placing in position, reinforcement TMT bars of 12 mm dia -1800 mm long (approx)-8 nos. and reinforcement ring of cold twisted bar of 8 mm dia - 2800 mm (approx) - 10 nos.(with 150 mm spacing) as required along with providing 1 m length 63 mm O.D. DWC HPDE pipe for cable entry and exit and positioning and fixing of 4 Nos. 24mm diameter x 750mm long MS anchor bolts with nuts & washers including suitable sized anchor plates etc complete as reqd. |
| 4 | Fabrication, Supply and erection of flange mounted hot dip Galvanized Octagonal Poles of 12 mtrs. Height made from 3 mm thick HT Steel plate, having bottom dia of 210 mm. & top dia of 90 mm. with base plate of size 300mm x 300mm x 16 mm thick complete with connection window having flash cover with round sleeve at an aprox. height of 2.5 mtrs from the base for cable termination etc. on the existing cement concrete pedestal as required i/c supplying and fixing of the following accesories in connection window for cable termination i/c credit / buyback for old dismantled material i/c dismantling as on where it is basis etc complete as required: -a) 6 mm thick laminated / backalite sheet of suitable size- 1 Nob) 63 Amp 4 Way termination block- 1 No.c) 6 Amp 10 KA, SPMCB,'C' Characteristics Curve - 1 nos. |
| 5 | Providing and laying in position M-20 reinforced cement concrete foundation of size 750 mm (L) x 750 mm (W) and 1800 mm (D) i/c excavation of earth, providing cutting, bending and placing in position, reinforcement TMT bars of 12 mm dia -2000 mm long (approx)-8 nos. and reinforcement ring of cold twisted bar of 8 mm dia - 3200 mm (approx) - 10 nos.(with 150 mm spacing) as required along with providing 1 m length 63 mm O.D. DWC HPDE pipe for cable entry and exit and positioning and fixing of 4 Nos. 24mm diameter x 850mm long MS anchor bolts with nuts & washers including suitable sized anchor plates etc complete as reqd. |
| 6 | Fabrication, Designing, Supplying & Fixing of Galvanized arm street light pole bracket (single/double/tripple over hang) with tightening bolt etc. as per existing design of brackets of roads where the street light pole bracket to be fixed or as per approved by Engineer-In-Charge. (Similiar type as per existing pole) |
| 7 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70 , under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)150 watt |
| 8 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection , EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 200 watt |
| 9 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (45 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 10 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe i/c credit / buyback for old dismantled material i/c dismantling as on where it is basis etc complete as required4x 16 sq.mm |
| 11 | Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required. |
| 12 | SITC of weather proof pole box made out of hot moulded SMC sheet of nominal size 240 mm x 130mm x 95 mm having lockable door with the help of clamp /fastner complete with 4 way Al Busbar / Connector, 1No. 6 Amps SPMCB, gland & lug/thimble i/c connections i/c credit / buyback for old dismantled material i/c dismantling as on where it is basis etc complete as required |
| 13 | Supplying and laying of one number PVC insulated and PVC sheated/XLPE aluminium conductor armoured power cable of 1.1 KV grade of following size overhead pole to pole with help of tower wagon/hydra, making connections i/c credit / buyback for old dismantled material i/c dismantling as on where it is basis etc complete as required4 x 10 sq.mm |
| 14 | Providing, boring and laying of 125 mm dia B - Class G.I. Pipe by trench less technology with no dig method by making bore hole in horizontal direction across the road as per direction of Engineer-In-Charge with mouling equipment i/c jointing cleaning, roadding of pipe. Providing, suitable covers on mouth of pipes, excavation of pits of required size at a depth of 1.30 mtrs. to 2.00 mtrs. |
| 15 | Supplying and drawing following sizes of PVC insulated copper conductor multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable copper lugs connections i/c credit / buyback for old dismantled material i/c dismantling as on where it is basis etc complete as required3 core x 1.5 sq. mm |
| 16 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 17 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 18 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 19 | Supplying, Installation, testing & commissioning of outdoor type front openable double door cubical Feeder Pillar of suitable size & depth duly fabricated with 2 mm thick CRCA sheet steel with heavy duty locking arrangement, dust & varmin proof duly powder coated in approved shade complete with 4 strip aluminium bus bar of 200 Amp. capacity of high conductivity with DMC/ SMC bus bar supports, two nos. earth studs, MV danger notice plate, power & control wiring, connection, interconnections etc. and fixing the same on MS angle iron frame of suitable size duly fabriceted with 50mm. x 50mm. x 6mm. (NS) having 4 nos 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggregate 20mm) complete with following switchgears & accessories therein etc complete as reqd i/c dismentling of old damaged feeder pillar & credit for old dismentled feeder pillar etc as requires.INCOMER:i) 1 No. 125 Amp, 25KA . 415 Volts TP MCCB ii) RYB LED phase indication lamps with protection MCB's- 1 Setiii) 95 Amp. TP Power contactor AC-3 rating with NO NC aux contacts- 1 No.iv) 24 Hr. digital Timer with Auto/Manual switch- 1 No. OUTGOINGS: i) 63Amps 415 Volts TP MCCB of 16 KA (Ics = Icu = 100%)- 2 Nos |
| 20 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete etc as required Total in Figures 4790043.0 365250.0 Forty Seven Lakh Ninety Thousand &Forty Three Only Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |