| 1 | Excavation in soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming, bottom and side slopes, in accordance with requirements of lines, grades and cross sections including all lifts and combined lead upto 30m. |
| 2 | Plain cement concrete M-15 plain/Reinforced cement concrete in open foundation complete as per drawings and technical specifications |
| 3 | Reinforced cement concrete grade M-25 in sub-structure complete as per drawing and Technical specifications using Batching plant,transit mixer and concrete pump (height upto 5m) |
| 4 | Reinforced cement concrete grade M-25 For solid slab super structure complete as per drawing and Technical specifications using Batching plant,transit mixer and concrete pump (height upto 5m) |
| 5 | Reinforced cement concrete grade M-25 For solid slab super structure complete as per drawing and Technical specifications using Batching plant,transit mixer and concrete pump (height 5m to 10 m) |
| 6 | Reinforced cement concrete grade M-30 For solid slab super structure complete as per drawing and Technical specifications using Batching plant,transit mixer and concrete pump (height upto 5m) |
| 7 | Reinforced cement concrete grade M-30 in sub-structure complete as per drawing and Technical specifications using Batching plant,transit mixer and concrete pump (height upto 5m) |
| 8 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth |
| 9 | Cold twisted deformed (Ribbed/Tor Steel Bar) Bars Fe500 grade as per IS 1786-1985, for R.C.C. works, where not including in the complete rate of R.C.C. including bending and placing in position complete in all respect. |
| 10 | Making bore and installation of pumping set for dewatering arrangements complete in all respect. |
| 11 | Providing, Running and maintenance of pumping set 8 H.P./Generator Set for dewatering arrangements complete in all respect. |
| 12 | Preparation of Plastered or concrete surface for Painting (including sand Papering the surface using ready mix cement based wall putty by applying two or more coat to get a required finish. |
| 13 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered,concrete surface to give an even shade. |
| 14 | Iron grated doors, including pintle hinges & arrangements. |
| 15 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes ( Fourway PVC1½\\"deep for walls and CI 3\\"deep for ceiling), bonding to earth with PVC insulated copper conductor singlecore FR cable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface): a)- Wiring fan point (With fan box). |
| 16 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes ( Fourway PVC1½\\"deep for walls and CI 3\\"deep for ceiling), bonding to earth with PVC insulated copper conductor singlecore FR cable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface): b)- Wiring light point. |
| 17 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes ( Fourway PVC1½\\"deep for walls and CI 3\\"deep for ceiling), bonding to earth with PVC insulated copper conductor singlecore FR cable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface): c)- Wiring call-bell point |
| 18 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes ( Fourway PVC1½\\"deep for walls and CI 3\\"deep for ceiling), bonding to earth with PVC insulated copper conductor singlecore FR cable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface): d)- Wiring 6Amp. wall socket point. |
| 19 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealedmetal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches,16/20Amp.switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes ( Fourway PVC1½\\"deep for walls and CI 3\\"deep for ceiling), bonding to earth with PVC insulated copper conductor singlecore FR cable (ISImarked) 1sq.mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface): e)- Wiring 16/20Amp. power plug control point. |
| 20 | Providing and fixing 110 mm dia. U.P.V.C Rain water pipe of 4kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction ofEngineer -in- charge. |
| 21 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. Vitreous chinaware standard white pedestal for wash hand basin. |
| 22 | Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 23 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A (b) 110mm o/d single socket SWR UPVC pipe lines laid complete |
| 24 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer-in charge) with cover with suitable locking arrangement and making necessary holes for inlet,outlet and over flopipes but without fittings and base support for tank.(i) Triple Layer Tanks |
| 25 | Gantry Crane for Pump house i/c Fabrication/erection: Welded plate box double girders,end carriages, seismic devices, walkways5T open winch trolley, electric wire rope hoist, motors,brakes, safety panel, overload limiter (5 m lift)QU100/QU120 heavy rails, complete fixing/aligning(43m runwayElectrical: Control panel, festoon/C track, cabling,earthing, limit switches, alarm, lightingFoundation bolts, baseplates, seismic anchoragesComplete Installation of allied items such as walkwaystaircase etc. along with commissioning and load testcomplete in all respect |
| 26 | Plain cement concrete M-10 (1:3:6) nominal mix in foundation with crushed stone aggregate 40mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. |
| 27 | Sand Filling in Foundation trenches as per Drawing and Technical Specification for 1 m cushion |
| 28 | Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marked as per IS code IS458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed.The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc. R.C.C. Pipe NP -3 Dia 700mm |
| 29 | Reinforced cement concrete grade M-20 in sub-structure complete as per drawing and Technical specifications using Batching plant,transit mixer and concrete pump (height upto 5m) |
| 30 | Filling stones or spall into crates and hand packing |
| 31 | Weaving wire netting for wire crates including binding sides and partitions to make crate of 15 cm x 15 cm mesh |
| 32 | Earthwork excavation in foundation, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and side of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 33 | Dressing of Side Slopes and prepration of sub grade for lining complete in all respect as per pwd specification |
| 34 | Laying cement water slurry 1:3, with cement @ 2.25 kg/sqms as on prepared side slopes before laying concrete on side slopes. |
| 35 | Cement concrete lining 75 mm thick or less with mechanical paver for irrigation channel using cement concrete M-15with cement content 325 Kg/cum mixed in automatic computerised batching and mixing plant and transported to site in transit mixer with an average lead of 1 km. |
| 36 | Cement concrete lining 75 mm thick or less laid manually for irrigation channel using cement concrete M-15with cement content 325 Kg/cum mixed in automatic computerised batching and mixing plant and transported to site in transit mixer with an average lead of 1 km. (forCoping, Transverse Sleepers, Toe Wall (Longitudinal), ) |
| 37 | Earthwork for compaction in 20 cm layers and dressing.Extra for watering the earth.Extra for rolling to specifications. |
| 38 | Dressing of earthwork New work or remodeling work |
| 39 | Earthwork for lip cutting for irrigation of channel inclusive of all allowances leads and dressing 0 to 1.5 mtr depth |
| 40 | Earthwork for lip cutting for irrigation of channel inclusive of all allowances leads and dressing above1.5 mtr depth but upto 3.0 m |
| 41 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface (for construction joint, Expansion Joint & Contraction Joint. Complete in all respect. |
| 42 | Providing & laying 250 mm wide LDPE Film 150 micron over sleepers |
| 43 | Excavation in soil using hydraulic JCB and Hydraulic Tractors Trolley i.e cutting & loading in trolley and transporting to the embankment location with all lifts and lead.( Disposal/carrige from 3kms) Please Enable Macros to View BoQ information |