| 1 | Schedule 'A' |
| 2 | Servicing of DG set of Cap 100 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lub oil filter.(b) Lubrication oil.Make of DG set: Ashok LeylandNote: Defective parts if any other than listed at (a) to (b) above will be measured and paid separately |
| 3 | Supply only parts/ Items of DG set 100 KVA (Make : Ashok Leyland) and taking down old unserviceable parts. |
| 4 | Oil Filter |
| 5 | Fuel Filter cum water separator |
| 6 | Air Filter Safety |
| 7 | Air Filter Primary |
| 8 | Coolant |
| 9 | Engine Oil |
| 10 | Fuel strainer |
| 11 | Distilled water for battery |
| 12 | Supply only parts/ Items of DG set 82.5 KVAMake : Kirlosker and taking down old unserviceable parts. |
| 13 | Oil Filter |
| 14 | Fuel Filter cum water separator |
| 15 | Air Filter Safety |
| 16 | Air Filter Primary |
| 17 | Coolant |
| 18 | Engine Oil |
| 19 | Fuel strainer |
| 20 | Distilled water for battery |
| 21 | Supply & Fixing in replacement of LED flood light 150 Watt LM6 high pressure die cast aluminium housing, IP 66, Nominal Lumen output 14000 lm, Colour temperature 5700K, THD<10%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engr-in-Charge. Make: Wipro/Philips |
| 22 | Supply & Fixing in replacement of LED street light of capacity 60 Watt, LM6 high pressure die cast aluminium housing, IP 66 protection, THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engr-in-Charge. Make: Wipro/ Philips |
| 23 | Supply & Fixing in replacement LED Bollard light Cool white 6500 K of wattage 14 watt with integrated mounting base plate and driver complete with housing dark grey RAL 7043 with long life time of 50,000 hours (70% lumen maintenance @ Tc = 35ºC), IP65 protection and IK10 impact resistance including PCC (1:2:4) foundation of suitable size for mounting of light fitting including mounting pole with accessories not less than 1.2m height, complete all as specified and directed by Engr-in-Charge. Make : Philips Cat No. BCP400 LED09 D CW PSU GR S1 or its equivalent in Wipro or equivalent make mentioned in Appendix 'B'. |
| 24 | Supply only items for APFC Panel and taking down old unserviceable parts. |
| 25 | Heavy duty gas filled Capacitor 5 KVAR, 440V, 3 phase, 50 Hz. Make: L&T Series No LTCCN or equivalent in Havells/C&S |
| 26 | Heavy duty gas filled Capacitor 7.5 KVAR, 440V, 3 phase, 50 Hz.Make: L&T Series No LTCCN or equivalent in Havells/ C&S |
| 27 | Heavy duty gas filled Capacitor 10 KVAR, 440V, 3 phase, 50 Hz. Make: L&T Series No LTCCN or equivalent in Havells/C&S |
| 28 | 8 Steps APFC RelayMake: L&T/C&S/Siemens |
| 29 | Material and labour for painting of the transformer 315 KVA complete by removing old paint by scrapping and providing spray painting two coats with synthetic enamel paint of approved make duly marking/writing MES/SM No., complete all as specified and directed by Engr-in-Charge. Make of transformer: RTS & ITE |
| 30 | Material & Labour for apply two coat of epoxy paint on LT Panel / LT APFC Panels/Servo stabilizer of any size, including preparation of rusted surface of panel by means of sand paper/scrubbing of dust etc and apply one coat of epoxy based primer before painting, complete all as specified and directed by Engr-in-Charge. Note: Minor repair/ replacement of hinges suitable for screw fasteners and fixed in original position deemed to be included in unit rate. |
| 31 | Supply and fixing in replacement of Digital time switches (SST 15 min) for street light 215 V single Phase, complete all as specified and directed by Engr-in-Charge. Make :L&T/Havells |
| 32 | Material & Labour for preparing old rusted surface of steel tubular pole by means of sand paper/scrubbing of dust etc and apply one coat of red oxide on surface of poles and applying two coats of silver paint on Pole and numbering of poles with synthetic enamel paint white in 100mm high letters over 150mm x 150mm black base, complete all as specified and directed by Engr-in-Charge. |
| 33 | Supply and fixing in replacement of thermoplastic cable junction box for street lights of size 205mm x 255mm x 112mm including bus bar/terminal for cable connection with IP-66 protection, complete all as specified and directed by Engr-in-Charge. Make : Hensel Cat No.DK 2525 G or its equivalent in Legrand /sintex |
| 34 | Material & Labour for bore Earthing 150mm bore for Earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres length, top edge of GI pipe 15 cm above GL, connected with Earthing lead of 25mm x 4mm GI strip to the Earthing test point and filling of charcoal dust, salt etc and testing on completion, including taking down old unserviceable Earthing, complete all as specified and directed by Engr-in-Charge. Note: IR Value should be less than 5 Ohms.Note: GI earth strip of size 25 x 4 including installation 7.5 Mtr and taking down old unserviceable Earthing is deemed to be included in the unit rate. |
| 35 | Supply & Fixing in replacement of Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable, complete all as specified and directed by Engr-in-Charge. of following sizes-Make-Denson/Siemen |
| 36 | 25 Sqmm to 50 Sqmm |
| 37 | 70 Sqmm to 95 Sqmm |
| 38 | Taking out UNSV LT UG cables of any sizes from trenches, complete all as specified and directed by Engr-in-Charge. |
| 39 | Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, complete all as specified and directed by Engr-in-Charge. of cross-sectional area:- |
| 40 | 120 Sqmm 3.5 Core |
| 41 | 95 Sqmm 3.5 Core |
| 42 | 50 Sqmm 3.5 Core |
| 43 | 35 Sqmm 3.5 Core |
| 44 | 25 Sqmm 3.5 Core |
| 45 | 16 Sqmm 4 Core |
| 46 | Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in hard/dense soil, complete all as specified and directed by Engr-in-Charge. |
| 47 | Returning filling in including spreading levelling watering and well Ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge. |
| 48 | Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 49 | Material & Labour for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:2:4; including removal of surpluses soil, complete all as specified and directed by Engr-in-Charge. |
| 50 | Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories, including taking down old unserviceable DWC pipe, complete all as specified and directed by Engr-in-Charge. Note: (i) Cutting of floor/ road and making good with PCC deemed to be included in item rate.Make: Rex/Poly/Gemini |
| 51 | 90mm OD |
| 52 | 63mm OD |
| 53 | 50mm OD |
| 54 | Supplying and laying in replacement of synthetic Rubber insulated mats 2mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engr-in-Charge. |
| 55 | Supplying and laying in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 56 | Supplying and laying in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |