| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) (As per DSR 4.1.10) |
| 2 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (As per DSR 5.3) |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (As per DSR 5.9.2) |
| 4 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (As per DSR 5.22A.6) |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) (As per DSR 6.4.1) |
| 6 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated hollock wood (As per DSR 9.1.3) |
| 7 | Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : (copper oxidized as per IS: 1378) 115 mm (As per DSR 9.67.2) |
| 8 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. (As per DSR 9.84) |
| 9 | Providing and fixing magnetic catcher of approved quality in cupboard /ward robe shutters, including fixing with necessary screws etc. complete. Double strip (horizontal type) (As per DSR 9.114.2) |
| 10 | Welding by gas or electric plant including transportation of plant at site etc. complete. (As per DSR 10.22) |
| 11 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand): 25 mm thick (As per DSR 11.26.1) |
| 12 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (As per DSR 11.27) |
| 13 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.1 Double charge vitrified tile polished finish of size Size of Tile 600x600 mm (As per DSR 11.41A.1.1) |
| 14 | Providing and laying double charge vitrified floor tiles of specified size (thickness to be specified by the manufacturer) of 1st quality with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. (N.S.) |
| 15 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter (As per DSR 12.41.2) |
| 16 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 12.42.5 Bend 87.5° 110 mm bend (As per DSR 12.42.5.2) |
| 17 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (As per DSR 12.44) |
| 18 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 Fine sand) (As per DSR 13.2.1) |
| 19 | 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) (As per DSR 13.16.1) |
| 20 | Pointing on brick work with cement mortar (1:3) : Flush / Ruled/ Struck or weathered pointing (As per DSR 13.31.1) |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm). (As per DSR 13.46.1) |
| 22 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (As per DSR 13.8) |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.99.1 One or more coats on old work (As per DSR 13.99.1) |
| 24 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (As per DSR 13.41.1) |
| 25 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (One or more coat applied @ 0.90 ltr/10 sqm). (As per DSR 13.111.2) |
| 26 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (As per DSR 14.5.1) |
| 27 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) (As per DSR 15.2.2) |
| 28 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (As per DSR 15.3) |
| 29 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar (As per DSR 15.7.4) |
| 30 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (As per DSR 15.56) |
| 31 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (As per DSR 15.60) |
| 32 | Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska : With F.P.S. brick tiles (As per DSR 14.18.1) |
| 33 | Cleaning of Roof including removal of grass, bushes and rubbish and disposal of malba to suitable place outside the premises. (N.S.) |
| 34 | Providing and fixing 35mm thick phenol bounded factory manufactured solid flush door shutter ISI marked with both side commercial face in the existing chowkhat. The rate includes the cost of iron hinges, all necessary Aluminium fittings and painting two coats over one coat of primer after preparation of surface (special quality) complete in all respect to the entire satisfaction of Engineer-in-charge. (N.S.) |
| 35 | Providing and fixing 35mm thick golden champ wood (kiln seasoned) glazed window shutters consisting of vertical and horizontal styles 75x35mm size with 4mm thick floated glass pane fixed with 1/2\\"x3/4\\" golden champ wood (kiln seasoned) beading. The rate further includes the cost of 2 nos. 3\\" hinges, 2 nos. Aluminium tower bolts 4\\", Aluminium handles 1 nos., I-hook and two coats of special quality enamel paint over coat of primer after preparation of surface (special quality) complete in all respect to the entire satisfaction of Engineer-in-charge. (N.S.) |
| 36 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. with necessary screws to the existing wooden frame including coat of synthetic enamel paint over one coat of primer complete in all respects and to the entire satisfaction of the Engineer in charge. (N.S.) |
| 37 | Providing and applying cement based putty (Birla, Jk or equivalent) to the required finish complete in all respect and to the entire satisfaction of Engineer-in-charge. (N.S.) |
| 38 | Providing and fixing of cupboard shutter consisting of 19mm thick commercial board with lipping all around and fixed with chowkhat frame with piano hinges and screws etc. and provide with Alum. handle (with base plate) and magnetic catcher. The board surface is to be painted with two coats of special quality synthetic enamel paint after primer coat and preparation of surface, complete frame is to be fixed with iron nails etc. complete in all respects and to the entire satisfaction ofthe Engineer in charge. (N.S.) |
| 39 | Repair of deteriorated RCC Balconies, Chajjas, Beams, Walls, Ceiling, Column or other concrete surface having exposed rusted bars consisting of following operations (a) chipping of concrete surface 25mm thick average depth afterwards remocal of loose concrete and exposing the steel bars. Cleaning the surface properly to remove dust particles and rust from the steel bars. (b) Moistening the surface properly and applying arcylic polymer (acrocrete/ pidilite/ mastercrete or its equivalent) coating mixed with cement for proper bonding of old and new concrete in two coats 0.2kg per 1kg of cement. (c) Providing and fixing chicken mesh of standard size and 26 guage with steel reinforcement by using binding wire and nails complete. (d) Proving and placing of cement concrete l:11/2:3 having average thickness 1\\" (3/4\\" to 11/4\\" thick) mixed with arcylic polymer admixture @ 1kg per bag of cement and waterproof agent @ 400ml per 2 bags of cement including finishing the surface complete in all respect as per the direction and to the entire satisfaction of Engineer-in-Charge. (N.S.) |
| 40 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats). (As per DSR 13.81.1) Please Enable Macros to View BoQ information |