| 1 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) DSR 1.27.6 |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm Make: KEI, Finolex, Cirtina, Havells, Polycab. DSR 1.17.1 |
| 3 | Supplying and fixing following way, horizontal type three pole and neutral, sheet stee, MCB Distribution Board, 415Volts, on recess, complete with tinned copper bus-bar, neutral bus-bar, earth bus-bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) of Make : Legrand/ Seimens/ Schneider/ L&T/ABB.4 Way (4 + 12), Double Door DSR 2.4.1 |
| 4 | Supplying and fixing of following size of ISI marked PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Size 25mm DSR 1.21.2 |
| 5 | G.I. Earth pipe electrode with salt/ Charcoal:-Supply and laying of earth electrode made out of ISI marked 'B' class G.I. pipe 4.5 Mtr. long 40 mm dia including accessories. GI pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom. The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge. DSR- 5.2 |
| 6 | P/F 6 SWG GI earth wire in pipe: Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required. DSR- 5.12 |
| 7 | LED Batten light with Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light including dismantling of existing unserviciable light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short &Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 ,Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testingfacilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy>135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Make: PHILIPS, Wipro, Bajaj, Havells,Twinkle, Surya, Halonix. . 18- 22 Watt DSR 8.11.1 |
| 8 | LED 50 WATT Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single cor cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. . Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). The luminary should be make Philips/ Crompton/ Havells/ Surya/ Wipro/ Bajaj/ Halonix. Dismantled light will be the property of the contractor. The work shall be executed upto entire satisfaction of EIC. DSR 8.17.1 |
| 9 | LED 100 WATT Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single cor cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. . Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). The luminary should be make Philips/ Crompton/ Havells/ Surya/ Wipro/ Bajaj/ Halonix. Dismantled light will be the property of the contractor. The work shall be executed upto entire satisfaction of EIC. DSR 8.17.3 |
| 10 | LED Panel light 2x2 ft., 36 WATT (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency>85%, Operating voltage AC 140-270 Volt, freq 50/60 hz,Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumenmaintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79& LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Make: PHILIPS, Wipro, Bajaj, Havells,Twinkle, Surya, Halonix. DSR 8.8.4 |
| 11 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR 1.25 |
| 12 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole . Make : Legrand/ Seimens/ Schneider/ L&T/ABB DSR 2.10.1 |
| 13 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A Make : Legrand/ Seimens/ Schneider/ L&T/ABB DSR 2.13.2 |
| 14 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness DSR 4.1.2 |
| 15 | Providing and fixing 200 A 36 KA 4 POLE rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Make : Legrand/ Seimens/ Schneider/ L&T/ABB DSR 2.2.15 |
| 16 | Providing and fixing 400 A 50 KA 4 POLE rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Make : Legrand/ Seimens/ Schneider/ L&T/ABB DSR 2.2.18 |
| 17 | Supply & Erection of DWC pipe 38/50mm with hand bockey:-Supply and laying of 38/50 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct/Gemini. The pipe should be laid 3 feet below ground/road level with hand bockey without cutting of road for laying cables etc. including cost of digging and refilling of pits complete in all respects to the entire satisfaction of Engineer-in-Charge of work. |
| 18 | Supplying and laying of following size DWC pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.38/50 mm |
| 19 | Supply & Laying of DWC pipe 50/63mm with out hand bockey:-Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /mini.. The pipe should be laid 3 feet below ground/road level by digging the ground upto 3 feet or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work.DSR 14.16.1 |
| 20 | Supplying and laying of following size DWC pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.50/63 |
| 21 | Supply & laying of ISI marked 4 core 16 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 16 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.1 MV CBPIP (external). The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. The specification of the cable as below:-i) Conductor – Aluminumii) Core – 4iii) Working Voltage – 1100 Viv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6vi) Insulation Thickness – 1.0mm (Nominal) vii) Inner Sheath Minimum Thickness – 0.3mm viii) Outer Sheath Minimum Thickness – 1.40mm ix) Nominal size of Armoured Wire/Strip – 4x0.8mm x) Approximate O.D. – 22mm Maximum d.c. Resistance at 20 Deg. C – 1.91 ohm/km The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 22 | Supply, Installation, Testing and Commissioning of Single Phase 230V 50hz, 30\\" (750 mm ), 1400±50rpm 340-380 watt fixed speed air circulation fan mounted on direction changeable bracket which is to be fixed with nuts and bolts on MS Iron Plate frame welded/fixed with the iron structure on top of the shed. The rate includes material/ fabrication/ labour cost of nuts/bolts and MS iron plate frame to be welded/ fixed with iron structure of the shed. Job includes rates of petty material such as nut, bolts, washers, pin plug top etc if required for installation of fan as per site requirement Nothing extra shall be paid on any account. The work should be done to the entire satisfaction of Engineer-in-charge. Warranty:- The fan should be comprehensively warranted to be repaired or replaced for any defect within 2years of installations. |
| 23 | S/E of Ceiling Fans 1400mm sweep without fan regulator including M.S. pipe as per site requirement and wiring complete in all respect Make Bajaj (Sabse Tej EE) or equivalent of Crompton, Orient, Havells, Atomberg including making connection with 23/.076' flexible wire to be adjacent fan point with regulator . The work shall be executed to the entire satisfaction of Engineer in charge. |
| 24 | Supply and Erection of Exhaust fan (heavy duty motor with copper wound metallic body) following size complete with motor, mettalic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation,epoxy powder coating along with mettalic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. Size 12\\" Sweep 900 RPM with louver of Havells make Turbo Force SP/ Orient make Industrial heavy duty / Crompton make HDEF EXHD 300- 6-1 / Bajaj make Supreme DLX only. |
| 25 | PAINTING & NUMBERING OF POLES 7.5/9 Mtr. LONG: -Painting of poles above ground level with two coats of Al paint of Nerolec/Asian/ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles the base should be painted with yellow and the number should be written in black letters of 3” in length. The Cement collar around the pole should be painted with two coats of good quality white colored snowcem. The job includes the cost of paint of existing Junction box cover with Red paint and any other petty material require to complete the job to the entire satisfaction of Engineer-in-charge. |
| 26 | Painting of pedestal size 1200x900x350mm/900x600x350mm with P.O. red paint complete in all respect and bonding to the existing earth etc. and platform of cement concrete 1:2:4 around the pillar box of size 3’x2’x0’-4”. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 27 | Supply & Erection of Three Phase Sensor based Timer and Contactor assembled in 22 gauge CRCA sheet enclosure duly powder coated with the following accessories (Three Phase) of Make Amsons /L&T/Scheinder or equivalent as approved by the Engineer-in-Charge. It shall conform to latest relevant IS Code:-1. It shall have 3 contactors of capacity 40 Amp. Each of made BCH, Legrand, L&T or Siemons. The contractor should be of AC-3 duty 2 pole, 220/240 V coil Voltage. 2. It shall have Auto/Manual switch, light activated switching system with allied accessories as required. 3. It shall have kit-kat fuse unit of 40 Amp capacity. The fuse unit shall conform to latest relevant IS code for protection of timers, bakelite sheet & other components as per requirement as site. 4. It shall be housed in a powder coated 22 gauge M.S sheet cabinet fo its protection. 5.The device shall be provided/fixed in the existing pedestal box in such a way so that it operates at correct time i.e. at rising/setting of Sun. The Sensor shall be included time watch to operate as required. The work shall be executed to the entire satisfaction of Engineer-in-charge. Warranty:- IT SHOULD STAND WARRANTY FOR ONE YEAR TOWARDS ANY MANUFACTURING DEFECTS. Please Enable Macros to View BoQ information |